Process Multimeter Fluke 787

Code: Fluke 787


 

Datasheet PDF, 0.14 Mb

Description

  • 0 to 1000 V DC/AC Voltage measure
  • 0 to 1 A Current measure
  • 0 to 20 mA, 4 to 24 mA Current source
  • DMM and loop calibrator in one tool
  • Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
  • Externally accessible battery for easy battery changes
  • 1000V overload protection on V, ohms, frequency
  • 150V overload protection on mA, backed up by 440 mA 1000V fuse
  • 25% Manual Step plus Auto Step and Auto Ramp on mA output
 

Standard accessories

  • AC70A Alligator Clips
  • C81Y Protective Yellow Holster with Flex-Stand™
  • One 9V alkaline battery
  • Quick Reference Guide
  • TL75 Safety-Designed Test lead Set
  • Users Manual
 

Recommended options

 

 

More products FLUKE

MULTIFUNCTION PROCESS CALIBRATOR FLUKE 725

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

MULTI-PRODUCT CALIBRATOR FLUKE 5500E

• Handheld digital multimeters
• Bench multimeters (up to 4½ digits)
• Clamp meters
• Electronic thermometers
• Oscilloscope recorders

 

LEAKAGE CURRENT CLAMP METER AC 60A FLUKE 360

• 1 µA up to 60 A Broad range of measurement
• 3 mA range and 1 µA of resolution
• wide 40 mm (1.5 in) jaw size

 

FLUKE 1555 MEGOHMMETER INSULATION RESISTANCE 250V/ 10KV

• Resistance Test range: 2 TO
• Test voltage: 10 kV

 

FLUKE 114 HANDHELD DIGITAL MULTIMETER ELECTRICAL 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• AutoVolt: automatic ac/dc voltage selection

 

FLUKE 712B RTD TEMPERATURE CALIBRATOR

• measure and simulate (13) different RTD types and resistance
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

FLUKE CNX 3000 WIRELESS DIGITAL MULTIMETER

• AC and DC voltage measurements to 1000V
• AC and DC current with 0.01 mA resolution
• Continuity, resistance, diode test, capacitance and frequency measurements
• MIN/MAX Recording
• CAT III 1000 V, Cat IV 600V; IP54

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 353

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• Accurately measure frequency up to 1 kHz

 

PORTABLE VIBRATION TESTER ANALYZER FLUKE 810

• On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime
• Fault severity scale with four severity levels helps you prioritize maintenance work
• Repair recommendations advise technicians on corrective action
• On-board context sensitive help provides real-time tips and guidance to new users
• 2 GB expandable on-board memory provides enough space for your machinery’s data