Process Multimeter Fluke 787

Code: Fluke 787


 

Datasheet PDF, 0.14 Mb

Description

  • 0 to 1000 V DC/AC Voltage measure
  • 0 to 1 A Current measure
  • 0 to 20 mA, 4 to 24 mA Current source
  • DMM and loop calibrator in one tool
  • Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
  • Externally accessible battery for easy battery changes
  • 1000V overload protection on V, ohms, frequency
  • 150V overload protection on mA, backed up by 440 mA 1000V fuse
  • 25% Manual Step plus Auto Step and Auto Ramp on mA output
 

Standard accessories

  • AC70A Alligator Clips
  • C81Y Protective Yellow Holster with Flex-Stand™
  • One 9V alkaline battery
  • Quick Reference Guide
  • TL75 Safety-Designed Test lead Set
  • Users Manual
 

Recommended options

 

 

More products FLUKE

FLUKE 289 HANDHELD DIGITAL DATA LOGGING MULTIMETER 4.5 DIGIT

• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture
• Low input impedance function (LoZ)
• Motor winding and low ohm measurement range
• Low pass filter

 

FLUKE 1577 MEGOHMMETER INSULATION MULTIMETER 500/ 1000V

• Insulation test: 0.1 MO to 600 MO
• Insulation test voltages: 500 V, 1000 V

 

FLUKE 190-062 190-062/S HANDHELD DIGITAL OSCILLOSCOPE 2X60 MHZ

• 2-channels isolated 60MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

FLUKE 87V HANDHELD DIGITAL MULTIMETER 4.5 DIGIT

• 4.5 digit
• 20,000 count resolution for precise measurements
• 0.05% basic accuracy
• True-rms ac voltage and current for accurate measurements on non linear signals
• Selectable filter for accurate voltage and frequency measurements on motor drives
• Built in thermometer lets you carry one less tool (TC probe included)

 

FLUKE TIX560 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

WIRELESS AC FLEXIBLE CURRENT CLAMPMETER FLUKE CNX I3000 IFLEX

• True-RMS AC current measurements to 2500 A
• 3% accuracy
• Memory recording up to 65,000 readings
• iFlex current probe allows you to get into tight, awkward spaces
• Backlit LCD display
• CAT IV 600 V, CAT III 1000 V


FLUKE 233 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.25% accuracy
• Remote Display
• Measure up to 1000 V ac and dc
• Measure up to 10 A (20 A for 30 seconds)
• 10,000 µF capacitance range
• Frequency to 50 kHz
• True-rms ac voltage and current for accurate measurements on non-linear signals

 

LEAKAGE CURRENT CLAMP METER AC 60A FLUKE 360

• 1 µA up to 60 A Broad range of measurement
• 3 mA range and 1 µA of resolution
• wide 40 mm (1.5 in) jaw size

 

PHASE ROTATION INDICATOR FLUKE 9040

• 3 phase indication
• Indication of phase rotation
• Clear LCD display
• No battery required