Thermocouple Temperature Calibrator Fluke 714

Code: Fluke 714


 

Datasheet PDF, 0.11 Mb

Description

  • -200 to 1800ºC Range Measure / simulate thrmocouple
  • -10 to 75 mV Range Measure / simulate voltage
  • Measure temperature from TC output
  • Simulate TC output
  • Operable with nine types of thermocouples
  • Calibrate linear TC transmitter with mV source function
  • Selectable ºF or ºC
  • Thermocouple mini-jack termination
  • Available as accessories: Fluke-700TC1 and TC2 Thermocouple Mini-plug Kits
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • NIST-traceable calibration report and data
 

More products FLUKE

FLUKE 721 PRESSURE CALIBRATOR

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 355

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• 1000 V AC + DC true-rms, 600 V AC, and 1000 V DC
• Accurately measure frequency up to 1 kHz
• Resistance to 400 Kohms

 

FLUKE 113 HANDHELD DIGITAL MULTIMETER 3 1/2 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• True-rms for accurate ac measurements on non-linear loads
• VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 743B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging

 

FLUKE 190-102 190-102/S HANDHELD DIGITAL OSCILLOSCOPE 2X100 MHZ

• 2-channels isolated 100MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

ELECTRIC PRESSURE CALIBRATOR FLUKE 719

• Best in class pressure measurement uncertainty of 0.025%
• Measure and source mA with best in class 0.015% accuracy
• 30 PSI and 100 PSI pressure ranges

 

FLUKE MEMOBOX 1744 THREE PHASE POWER QUALITY LOGGER

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• IP65 water-proof

 

FLUKE TIS60 INFRARED CAMERA 260X195

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

TEMPERATURE AND HUMIDITY METER FLUKE 971

• Temperature range from -20 °C to 60 °C (-4°F to 140 °F)
• Relative humidity from 5 % to 95 %
• Min/Max/Avg Data hold
• Low battery indicator

 

FLUKE 115 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• AC/DC Current
• Capacitance and Frequency