Fluke 721 Pressure Calibrator

Code: Fluke 721 721-1601 721-1603 721-1605 721-1610 721-1630 721-1650 721-3601 721-3603 721-3605 721-3610 721-3615 721-3630 721-3650


 

Datasheet PDF, 0.76 Mb
   

Description

Pressure Calibration and Temperature Measurement for Custody Transfer Applications

The ideal tool for gas custody transfer applications is the Fluke 721 Precision Pressure Calibrator. With dual isolated pressure sensors, it allows you to take simultaneous static and differential pressure measurements with a single tool.

 

The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar). 


  • Ideal for gas flow calibration (custody transfer) applications
  • Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
  • Pt100 RTD input for temperature measurement, (probe optional)
  • Measures 4 to 20 mA signals
  • Internal 24 V loop power supply can power a transmitter under test
  • Measure up to 30 V dc, check 24 V loop power supplies
  • Extend pressure measurement range with connection to external 700 series pressure modules (29 ranges)
  • Large backlit graphic display can display up to three inputs simultaneously
  • Store five instrument setups for recall and use

 

 

Standard accessories

Fluke-721-1601           Dual Sensor Pressure Calibrator, 16 PSIG, 100 PSIG

Fluke-721-1603           Dual Sensor Pressure Calibrator, 16 PSIG, 300 PSIG

Fluke-721-1605           Dual Sensor Pressure Calibrator, 16 PSIG, 500 PSIG

Fluke-721-1610           Dual Sensor Pressure Calibrator, 16 PSIG, 1000 PSIG

Fluke-721-1615           Dual Sensor Pressure Calibrator, 16 PSIG, 1500 PSIG

Fluke-721-1630           Dual Sensor Pressure Calibrator, 16 PSIG, 3000 PSIG

Fluke-721-1650           Dual Sensor Pressure Calibrator, 16 PSIG, 5000 PSIG

Fluke-721-3601           Dual Sensor Pressure Calibrator, 36 PSIG, 100 PSIG

Fluke-721-3603           Dual Sensor Pressure Calibrator, 36 PSIG, 300 PSIG

Fluke-721-3605           Dual Sensor Pressure Calibrator, 36 PSIG, 500 PSIG

Fluke-721-3610           Dual Sensor Pressure Calibrator, 36 PSIG, 1000 PSIG

Fluke-721-3615           Dual Sensor Pressure Calibrator, 36 PSIG, 1500 PSIG

Fluke-721-3630           Dual Sensor Pressure Calibrator, 36 PSIG, 3000 PSIG

Fluke-721-3650           Dual Sensor Pressure Calibrator, 36 PSIG, 5000 PSIG

Fluke-720RTD            RTD Probe for 721 and 719Pro

Fluke-720URTDA      Universal RTD adapter for Fluke-721 and 719Pro

 

                     Soft case

                     Four (4) AA batteries

                     Manual

                     Traceable calibration certificate

                     Test leads

 

 

Recommended options

Fluke-720RTD            RTD Probe for 721 and 719Pro

Fluke-720URTDA      Universal RTD adapter for Fluke-721 and 719Pro

 

More products FLUKE

FLUKE 1630 EARTH GROUND CLAMP METER

• resistance range from 0.025 O to 1500 O
• large jaw opening of 35 mm
• ground leakage current, from 0.2 mA to 1000 mA
• ac current measurement range from 0.2 A to 30 A

 

FLUKE TIS50 INFRARED CAMERA 220X165

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 1507 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

• Insulation test range: 0.01 MO to 10 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

FLUKE VT02 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 20° X 20°
• 4 GB Micro SD card

 

HVAC CURRENT CLAMP METER 600 A FLUKE 902

• Designed for HVAC applications
• capacitance, DC Current (µA), and temperature measurements
• Small body and jaws

 

LASER DISTANCE METER 50M FLUKE 414D

• Instantly measures up to 50m (165 feet) with one button
• Laser accuracy of +/- 2mm (0.08 in)
• Easy, automatic math for area and volume, add and subtract with ease

 

FLUKE 1652C MULTIFUNCTION INSTALLATION TESTER 250V-1000V

• Test voltage: 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results

 

FLUKE 83V HANDHELD DIGITAL MULTIMETER 3.75 DIGIT

• 3.75 digit
• 6000 count resolution
• 0.1% basic accuracy

 

INFRARED THERMOMETER WITH CONTACT THERMOCOUPLE FLUKE 561 HVAC PRO

• IR Thermometer with K-type thermocouple capability
• IR thermometer for quick measurements up close, or at a distance, without a ladder
• Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
•  Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
• Single-point laser sighting
• Temperature range of -40 °C to 550 ° C (-40 °F to 1022 °F) covers most industrial and residential applications

 

FLUKE 190-104 190-104/S HANDHELD SCOPEMETER OSCILLOSCOPE 4X100 MHZ

• 4-channels isolated 100MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity