Multifunction Process Calibrator Fluke 726

Code: Fluke 726


 

Datasheet PDF, 0.53 Mb

Description

  • 0 to 100 mV, 0 to 30 V DC Voltage measure
  • 0 to 100mV, 0 to 20 V DC Voltage source / simulate
  • 0 to 24 mA Current measure / source / simulate
  • 0 to 4000 O Resistance measure / source / simulate
  • 1 to 15 kHz Frequency measure / source / simulate
  • More precise measurement and calibration source performance, accuracies of 0.01%.
  • Two separate channels; measure, source and view process signals simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters
  • Measure or source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Integrated pressure switch test allows you to capture the set, reset and deadband of a switch
  • Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis
  • Transmitter error% calculation, interpret calibration results without a calculator
  • Perform fast linearity tests with auto step and auto ramp features
  • Power transmitters during test using 24 V loop supply and simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing
  • HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation
  • Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement.
  • New voltage input protection design for improved reliability
  • Three-year warranty
 

Standard accessories

  • One set of AC72 alligator clips
  • One set of stackable test leads
  • One set of TL 75 testleads
  • User manuals
  • NIST- traceable calibration report and data
 

More products FLUKE

CURRENT CLAMP METER TRUE-RMS 600 A FLUKE 373

• 600 A AC current measurement with fixed jaw
• 600 V AC and DC voltage measurement
• True-rms ac voltage and current
• 6000 O resistance measurement
• 1000 µF capacitance measurement

 

FLUKE 125B 125B/S INDUSTRIAL SCOPEMETER HAND-HELD OSCILLOSCOPE 2X40MHZ

• 2-channel 40MHz
• Dual-input digital oscilloscope and multimeter
• 40 MHz or 20 MHz oscilloscope bandwidth
• Two 5,000-count true-rms digital multimeters
• Power measurements (W, VA, VAR, PF, DPF, Hz)
• Voltage, current and power harmonics
• Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*

 

VOLTAGE DETECTOR FLUKE 2AC VOLTALERT

• Voltage detection from 200 to 1000 V AC
• Category IV - 1000 V overvoltage rated product

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 325

• 400 A ac and dc current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement
• Frequency measurement

 

LOOP CURRENT PRECISION CALIBRATOR FLUKE 709

• Functions: mA source, mA simulate, mA read, mA read/loop power and volts read
• Best-in-class accuracy at 0.01% reading
• Small rugged design operates on (6) standard AAA batteries
• Intuitive user interface with Quick-Set knob for fast setup, easy use
• Built in selectable 250 ? resistor for HART communication

 

FLUKE 6306 AUTOMATIC RCL METER 50 HZ..1 MHZ

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQâ„¢ Mode: Estimated leak size and cost.
• PDQ Modeâ„¢: Assesses discharge severity.
• MecQâ„¢ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.

 

FLUKE 700HTPK HYDRAULICTEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
• Generates pressure up to 10,000 psi range or greater, to make a complete pressure testing kit
• Connect the 700G Series gauge directly to the HTP-2 hand pump
• Includes 700HTH-1 hose kit and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

FLUKE TIX520 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

FLUKE VT04 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 28° X 28°
• 4 GB Micro SD card