Handheld Temperature Calibrator Fluke 724

Code: Fluke 724


 

Datasheet PDF, 0.54 Mb

Description

  • -10 to 75 mV, 0 to 10 V Voltage source
  • -10 to 75 mV, 0 to 30 V Voltage measure
  • 0 to 24 mA Current measure
  • 0 to 3200 O Resistance measure / source
  • Easy to read dual display lets you view input and output simultaneously
  • Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
  • Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
  • Perform fast linearity tests with 25% and 100% steps
  • Execute remote tests with auto step and auto ramp
  • Power transmitters during test using loop power supply with simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Compact, streamlined shape makes it easy to carry
  • Rugged, reliable design stands up to field use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes
 

Standard accessories

  • AC70A Test Clips
  • One pair of stackable test leads
  • TL75 Test Leads
  • CE and CSA Markings
  • Manual
  • Users manuals on CD-ROM
  • NIST- traceable calibration report and data
 

More products FLUKE

AIR FLOW METER FLUKE 922

• Air Pressure
• Air Velocity
• Air Flow (Volume)
• Temperature

 

FLUKE 6306 AUTOMATIC RCL METER 50 HZ..1 MHZ

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 355

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• 1000 V AC + DC true-rms, 600 V AC, and 1000 V DC
• Accurately measure frequency up to 1 kHz
• Resistance to 400 Kohms

 

FLUKE 1587 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

• Insulation test: 0.01 MO to 2 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

• 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
• 0.1 % basic accuracy (0.05 % for PM 6304C)
• Easy to use, at-a-glance display

 

INDUSTRIAL VOLTAGE AND CURRENT MEASUREMENT SYSTEM FLUKE CNX 3000 IND

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• True-RMS AC voltage measurements to 1000V
• CAT III 1000 V, CAT IV 600 V, CAT III 1000 V; IP42


VOLTAGE CONTINUITY TESTER FLUKE T90/ T110/ T130/ T150

• Voltage AC/DC 12V - 690V
• Continuity 0 - 400 k?
• Frequency 0 / 40 - 400 Hz
• Phase rotation
• Resistance measurement

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

MILIAMP PROCESS CLAMP METER FLUKE 772

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity