Fluke 1555 Megohmmeter Insulation Resistance 250V/ 10kV

Code: Fluke 1555


 

Datasheet PDF, 0.1 Mb

Description

  • Resistance Test range: 2 TO
  • Test voltage: 10 kV
  • CAT III 1000 V, CAT IV 600 V safety rating
  • Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
  • Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
  • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
  • Long battery life gives the user over 750 tests between charges
  • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
  • Guard system eliminates the effect of surface leakage current on high-resistance measurements
  • Large digital/analog LCD for easy viewing
  • Capacitance and leakage current measurement
  • Ramp function for breakdown testing
  • Resistance measurements up to 2T?
  • Timer settings up to 99 minutes for timed tests
 

Standard accessories

  • Test Cables with Alligator Clips (red, black, green)
  • Infrared adapter with interface cable
  • FlukeView Forms Basic CD-ROM
  • AC Power Cord
  • Soft Carrying Case (base model only)
  • English Manual
  • User's Manual on CD-ROM
  • Quick Reference Card
  • Software License Agreement
  • Registration Card
  • FlukeView Forms Installation Guide
  • USB-IR Cable Installation Guide
 

Recommended options

FLUKE 1555/KIT 10kV Insulation Tester Kit

Includes IP67 hard case instead of soft case and certificate of calibration 

 

More products FLUKE

INTRINSICALLY SAFE PRESSURE CALIBRATOR FLUKE 718

• ATEX II 1G Ex ia IIC T4 Compliant
• Built-in pressure / vacuum hand pump
• Pressure measurement to 0.05%
• Pressure measurement to 200

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 324

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement

 

FLUKE 8845A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0035 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution

 

FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.

 

FLUKE 345 POWER QUALITY CLAMP METER

• 2000A AC/DC current
• 600 V CAT IV power analyzer
• Data logging
• Troubleshoot harmonics
• Inrush current

 

FLUKE 1653B MULTIFUNCTION INSTALLATION TESTER 50V-1000V

• Test voltage: 50V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance

 

TEMPERATURE AND HUMIDITY METER FLUKE 971

• Temperature range from -20 °C to 60 °C (-4°F to 140 °F)
• Relative humidity from 5 % to 95 %
• Min/Max/Avg Data hold
• Low battery indicator

 

FLUKE 1621 EARTH GROUND TESTER

• 3-pole Fall-of-Potential earth testing for basic measurements
• 2-pole resistance measurements for added versatility
• 600 V Cat II

 

MULTIFUNCTIONAL TESTER FOR TEMPERATURE, HUMIDITY, VELOCITY, CO, CO2 FLUKE 075 AIRMETER

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

FLUKE 700G/TRACK DATALOGGING SOFTWARE FOR 700G PRESSURE GAUGES

• Precision pressure measurement from -20 mbar to 690 bar
• Absolute pressure measurement ranges 15, 30, 100, 300 psia
• Accuracy to 0.05 % of full scale
• Reference class gauge accuracies to 0.04 % of reading