Fluke 1555 Megohmmeter Insulation Resistance 250V/ 10kV

Code: Fluke 1555


 

Datasheet PDF, 0.1 Mb

Description

  • Resistance Test range: 2 TO
  • Test voltage: 10 kV
  • CAT III 1000 V, CAT IV 600 V safety rating
  • Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
  • Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
  • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
  • Long battery life gives the user over 750 tests between charges
  • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
  • Guard system eliminates the effect of surface leakage current on high-resistance measurements
  • Large digital/analog LCD for easy viewing
  • Capacitance and leakage current measurement
  • Ramp function for breakdown testing
  • Resistance measurements up to 2T?
  • Timer settings up to 99 minutes for timed tests
 

Standard accessories

  • Test Cables with Alligator Clips (red, black, green)
  • Infrared adapter with interface cable
  • FlukeView Forms Basic CD-ROM
  • AC Power Cord
  • Soft Carrying Case (base model only)
  • English Manual
  • User's Manual on CD-ROM
  • Quick Reference Card
  • Software License Agreement
  • Registration Card
  • FlukeView Forms Installation Guide
  • USB-IR Cable Installation Guide
 

Recommended options

FLUKE 1555/KIT 10kV Insulation Tester Kit

Includes IP67 hard case instead of soft case and certificate of calibration 

 

More products FLUKE

LEAKAGE CURRENT CLAMP METER AC 60A FLUKE 360

• 1 µA up to 60 A Broad range of measurement
• 3 mA range and 1 µA of resolution
• wide 40 mm (1.5 in) jaw size

 

FLUKE 345 POWER QUALITY CLAMP METER

• 2000A AC/DC current
• 600 V CAT IV power analyzer
• Data logging
• Troubleshoot harmonics
• Inrush current

 

DIGITAL PYROMETER FLUKE 63

• Single point offset laser sighting
• Best accuracy in its class: + 1% of reading
• Holds temperature readings for 7 seconds
• Dual displays shows current and MAX measurements simultaneously
• Backlit display for poorly lit areas
• Wide temperature range from -30º to 500ºC (-20º to 932ºF)

 

INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

WIRELESS AC VOLTAGE MODULE FLUKE CNX V3000

• True-RMS AC voltage measurements to 1000V
• ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT IV 600 V, CAT III 1000 V; IP42


DOCUMENTING PROCESS CALIBRATOR FLUKE 741B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate

 

FLUKE 177 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count resolution
• 0.09% basic accuracy
• True RMS voltage and current measurements
• Digital display with analog bargraph and backlight

 

FLUKE 1550C MEGOHMMETER INSULATION RESISTANCE 250V/ 5KV

• Resistance Test range: 1 TO
• Test voltage: 5 kV

 

INTRINSICALLY SAFE PRESSURE CALIBRATOR FLUKE 718

• ATEX II 1G Ex ia IIC T4 Compliant
• Built-in pressure / vacuum hand pump
• Pressure measurement to 0.05%
• Pressure measurement to 200

 

FLUKE TIS55 INFRARED CAMERA 220X165

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels