Intrinsically Safe Pressure Calibrator Fluke 718

Code: Fluke 718


 

Datasheet PDF, 0.54 Mb

Description

  • ATEX II  1G Ex ia IIC T4 Compliant
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
  • Wide range of selectable measurement units for pressure
  • Current measurement with 0.02% accuracy and 0.001 mA resolution
  • Pressure switch test function
  • Min-Max Hold functions
  • Compact size and weight
  • Simple, push-button user interface
  • Rugged and reliable, ideal for field use
 

Standard accessories

  • Protective Red Holster
  • TL75 Test Leads
  • AC72 Test Clips
  • CD Users Manuals
  • Fluke 718Ex CCD content control drawing
  • NIST- traceable calibration report and data
 

Recommended options

Fluke 718EX 30

Pressure Calibrator 30 PSI, EX - I.S.

Fluke 718EX 100G

Pressure Calibrator 100 PSI, EX - I.S

Fluke 718EX 300G

Pressure Calibrator 300 PSI, EX - I.S

 

More products FLUKE

VOLTAGE CONTINUITY TESTER FLUKE T100

• Display: 12 LED's
• Voltage test
• Optical and acoustical continuity test

 

PRECISION INFRARED THERMOMETER FLUKE 574

• Backlit display for poorly lit areas
• Last ten temperature readings displayed on bar graph for easy reference
• Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
• Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
• MIN/MAX measurements calculations instantly computed
• Audible and visible HI temperature alarm for instant recognition
• 100 temperature data logging capability for easy route review

 

FLUKE TOPAS 1760 THREE PHASE POWER QUALITY RECORDER

• 8 input channels
• Fully IEC 61000-4-30 Class-A standard compliant
• Power quality statistics according to EN50160, DISDIP tables, ITIC, CEBEMA, ANSI
• 10 MHz, 6000 Vpk waveform capture
• GPS time synchronization
• records rms, min, max values for: Voltage Current Power P, Q, S Power Factor kWh Flicker Unbalance Frequency Harmonics Interharmonics

 

THERMOCOUPLE TEMPERATURE CALIBRATOR FLUKE 714

• -200 to 1800ºC Range Measure / simulate thrmocouple
• -10 to 75 mV Range Measure / simulate voltage
• Measure temperature from TC output

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 353

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• Accurately measure frequency up to 1 kHz

 

VOLTAGE CONTINUITY TESTER FLUKE T90/ T110/ T130/ T150

• Voltage AC/DC 12V - 690V
• Continuity 0 - 400 k?
• Frequency 0 / 40 - 400 Hz
• Phase rotation
• Resistance measurement

 

FLUKE TIS60 INFRARED CAMERA 260X195

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

FLUKE 115 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• AC/DC Current
• Capacitance and Frequency

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration