True-rms Current Clamp Meter 400 A Fluke 323

Code: Fluke 323


 

Datasheet PDF, 0.9 Mb
   

Description

Measurement capability

  • 400 A ac current measurement
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 40 k? with continuity detection


Features

  • Slim, ergonomic design
  • CAT IV 300V/CAT III 600 V safety rating
  • Hold button
  • Two-year warranty
  • Soft carrying case
 

Standard accessories

  • Test leads
  • Soft case
  • User's manual
 

Recommended options

 

 

More products FLUKE

FLUKE TIS60 INFRARED CAMERA 260X195

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE TIS10 INFRARED CAMERA 80X60

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

MULTIFUNCTIONAL TESTER FOR TEMPERATURE, HUMIDITY, VELOCITY, CO, CO2 FLUKE 075 AIRMETER

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 741B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate

 

POWER QUALITY CLAMP METER FLUKE 345

• 2000A AC/DC current
• 600 V CAT IV power analyzer
• Data logging
• Troubleshoot harmonics
• Inrush current

 

FLUKE 1653B MULTIFUNCTION INSTALLATION TESTER 50V-1000V

• Test voltage: 50V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance

 

AIR FLOW METER FLUKE 922

• Air Pressure
• Air Velocity
• Air Flow (Volume)
• Temperature

 

FLUKE 1750 THREE PHASE POWER LOGGER

• Power quality that meets the standard: comply with IEC61000-4-30 standards for voltage, current, power, harmonics, flicker etc.
• 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events
• 5 MHz Transient Voltage
• Captures everything
• Plug and play
• Wireless connection

 

WIRELESS CURRENT CLAMP FLUKE CNX A3000

• True-RMS AC current measurements to 400 A
• 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT III 600 V; IP42


FLUKE 190-062 190-062/S HANDHELD DIGITAL OSCILLOSCOPE 2X60 MHZ

• 2-channels isolated 60MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity