Current Clamp Meter AC/DC True-rms 2000 A Fluke 353

Code: Fluke 353


 

Datasheet PDF, 0.48 Mb

Description

  • Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings
 

Standard accessories

  • C43 Soft carrying case
  • 6 AA batteries
  • User manual
  • 3 year warranty
 

More products FLUKE

WIRELESS TEMPERATURE K-TYPE DATA ACQUISITION MEASUREMENT KIT FLUKE FLK-CNX T3000 KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• Temperature measurements from -200 °C to 1372 °C
• Memory recording up to 65,000 readings


FLUKE TIS10 INFRARED CAMERA 80X60

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 8808A DIGITAL BENCH MULTIMETER 5.5 DIGIT

• 5.5 digit resolution
• Basic V dc accuracy of 0.015 %
• Dual display

 

CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 376

• iFlex fexible current probe included, 18-inch circumference
• 2500 A AC current measurement with iFlex
• 1000 A AC current measurement with fxed jaw
• 1000 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60-k O resistance measurement
• 500 mV DC measurement range
• 1000 µF capacitance measurement

 

FLUKE 190-062 190-062/S HANDHELD DIGITAL OSCILLOSCOPE 2X60 MHZ

• 2-channels isolated 60MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

FLUKE TIS45 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

LASER DISTANCE METER 60M FLUKE 416D

• Ability to measure up to 60 m (200 ft) with increased accuracy of up to 1.5 mm (0.06 in)
• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.

 

MILIAMP PROCESS CLAMP METER FLUKE 773

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
• 0 to 30 V DC Voltage measure
• 0 to 10 V DC Voltage source