Fluke 1730 Three-Phase Energy Logger

Code: Fluke 1730


 

Datasheet , 0.33 Mb
       

Description

Easily Discover Opportunities for Energy Savings for Your Facility

Designed specifically for energy conscious customers like you, the Fluke 1730 Three-Phase Electrical Energy Logger introduces a new simplicity to discovering sources of electrical energy waste. Profiling energy usage across your facility helps you identify opportunities for energy savings and provides you with the easy-to-understand data required for you to take the right action.

 

With the 1730, you can:

  • Easily discover when and where energy is being consumed in your facility, from the service entrance to the individual circuits.
  • Compare multiple data points over time and build the complete picture of energy usage with the energy analyze software package.
  • Quickly understand specific points of energy loss, reduce energy bills more easily than ever.

The Fluke 1730 is the best choice when looking for a dedicated energy logger for performing energy surveys and load studies.

 

Take Energy Surveys to the Next Level

If you’re looking to take your energy surveys to the next level, show up with the 1730 Energy Logger and a VT02 Visual IR Thermometer or the Ti125 Infrared Camera to quickly identify opportunities for energy savings both electrically and thermally. When using an infrared camera or a visual IR thermometer along with the 1730 Energy Logger, you’ll be able to discover potential problems that could be wasting energy and then quantify them electrically with the 1730 Energy Logger. The perfect tool set to discover hidden operational wastes such lighting, air conditioning and other large loads that could be switched off when not in use.

 

 

 

  • Key measurements: Voltage, current, power, power factor and associated values enable you to optimize and implement your energy saving strategies.
  • Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display.
  • Comprehensive logging: More than 20 separate logging sessions can be stored on the instrument. In fact, all measured values are automatically logged and can be reviewed during logging and before downloading for on-the-go analysis.
  • Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
  • Complete "in-the-field" setup through the front panel: no need to return to the workshop for download and setup or to take a computer to the electrical panel.
  • Wide range power: power instrument directly from the measured circuit eliminating the need to find a power outlet while allowing the instrument to be secured safely inside electrical panels.
  • Two USB ports: one for PC connection and another for fast, simple download to standard USB thumb drives, or other USB devices.
  • Compact size: designed to fit in tight spaces and panels.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
  • Optimized measurement accessories: flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
  • Battery life: four-hour operating time (backup time) per charge on lithium-ion battery.
  • Security: We safeguard your best asset from theft with a hefty, durable Kensington lock.
  • Energy analyze application software: Download and analyze a snapshot of your energy savings potential with our automated reporting.
 

Standard accessories

 

Model Name

Description

1730/BASIC

Portable Energy Logger (excludes current probes)

1730/EU

Portable Energy Logger EU Version

 

Cables and Hardware

1730-Cable

AUX input cable

 

Cases and Holsters

1730-Hanger

Hanging Strap

C1730

1730 Soft Case

 

Current clamps

i1730-flex1500

1500A 12 inch

i1730-flex1500/3pk

1500A 12 inch, 3 pack

i1730-flex3000

3000A 24 inch

i1730-flex3000/3pk

3000A 24 inch, 3 pack

i1730-flex6000

6000A 36 inch

i1730-flex6000/3pk

6000A 36 inch, 3 pack

i40s-EL/3pk

40A Clamp-on Current Transformer, 3 pack

 

Test Leads

1730-TL0.1M

1000 V CAT III, straight plug; 0.1 m; silicone; red/black

1730-TL2M

1000 V CAT III; straight plug; 2 m; PVC red/black

3PHVL-1730

Cable Assembly, Voltage Test Lead 3-Phase+N

WC100

WC100 Color Localization Set

 

 

 

 

 

More products FLUKE

FLUKE NORMA 5000 PRECISION POWER ANALYZER

• 3, 4 or 6 power phases
• Bandwidth from dc to 3 MHz / 10 MHz
• FFT analysis, vector diagram, and Digital Oscilloscope
• Voltage, current and power harmonics measured up to the 40th harmonic

 

FLUKE 1652C MULTIFUNCTION INSTALLATION TESTER 250V-1000V

• Test voltage: 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results

 

INFRARED THERMOMETER WITH CONTACT THERMOCOUPLE FLUKE 566/ FLUKE 568

• Measure -40 °C to 800 °C /-40 °F to 1472 °F (568) or -40 °C to 650 °C/-40 °F to 1202 °F (566)
• Easily access advanced features with the soft-key buttons and dot-matrix display
• Measure smaller objects from further away, with a distance-to-spot ratio of 50:1 (568) or 30:1 (566)
• Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments

 

FLUKE 77IV HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count resolution
• 0.3% basic accuracy
• Large display
• Backlight for work in dim areas

 

INFRARED NON-CONTACT THERMOMETER FLUKE 62 MAX

• Dust and water-resistant: IP54 rated for dust and water resistance.
• Rugged: 3-meter (9.8-foot) drop tested.
• Ergonomically designed: Completely redesigned for a more natural hand fit.
• Large, backlit display: Large screen makes data easier to read, even in dark areas.
• Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.
• Alarm: Hi and Lo alarms for rapid display of measurements outside the limits

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 743B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging

 

WIRELESS AC CURRENT MEASUREMENT KIT FLK-CNX I3000 IFLEX KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• Memory recording up to 65,000 readings
• CAT III 1000, CAT IV 600 V; IP42


FLUKE 287 HANDHELD DIGITAL DATA LOGGING MULTIMETER 4.5 DIGIT

• 4.5 digit large ¼ VGA display with white backlight
• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture

 

FLUKE 1750 THREE PHASE POWER LOGGER

• Power quality that meets the standard: comply with IEC61000-4-30 standards for voltage, current, power, harmonics, flicker etc.
• 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events
• 5 MHz Transient Voltage
• Captures everything
• Plug and play
• Wireless connection

 

VOLTAGE DETECTOR FLUKE LVD1 VOLT LIGHT

• Detects voltages from 40 V AC to 300 V AC
• Non-contact AC voltage detector and LED flashlight
• exclusive dual-sensitivity