FLUKE TiX520 Infrared Camera 320x240

Code: FLUKE TiX520


 

Datasheet PDF, 1.8 Mb

Description

Models:
 

Fluke TiX500 320x240 pixels, -20 °C..+650 °C

Fluke TiX520 320x240 pixels, -20 °C..+850 °C

Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 
 

Fluke TiX520 Infrared Camera

 
 

 

 

  • The largest 5.7 inch responsive LCD touchscreen for a 320x240 infrared camera
  • 180° articulating lens for those tough shots
  • Premium image quality with leading spatial resolution for a 320x240 infrared camera¹
  • Get up to 4 times the resolution and pixels than standard mode with SuperResolution (up to 307,200 pixels)
  • LaserSharp® Auto Focus - utilizing precision laser technology, focus on your target with pinpoint accuracy and get the correct image and temperature measurements you need
  • Built-in laser distance meter - calculates the distance to your designated target up to 100 feet (30 meters) and displays the distance on the image
  • Quick and easy in-field analysis with IR-Fusion® technology and advanced touchscreen functions:
    • Continuous level and span adjustment 
    • Filter mode for improved thermal sensitivity
  • Post capture image editing includes:
    • Emissivity
    • Background temperature
    • Transmissivity
    • Palettes
    • Color alarms
    • IR-Fusion
    • Enable/disable markers
  • Connect to the largest network of wireless test and measurement tools with Fluke Connect™ (not available in all countries)
  • Temperature measurements up to 850 °C
  • Light and ergonomic design with neck and hand strap for all day use
  • Optional field installable wide angle and telephoto lenses

 

 

 
 

Standard accessories

  • Thermal imager with standard infrared lens
  • Ac power supply and battery pack charger (including universal ac adapters)
  • Two, rugged lithium ion smart battery packs
  • USB cable
  • HDMI video cable
  • Bluetooth headset (where available)
  • Rugged, hard carrying case
  • Adjustable neck and hand strap
  • Flash drive with SmartView® Software and user manual
  • Warranty registration card and calibration certificate

 

 

 

Recommended options

FLK-LENS/TELE2

2 teleobiective IR

 

FLK-LENS/4XTELE2

4 teleobiective IR

 

BOOK-ITP

Introducere în principiile termografiei

 

FLK-LENS/WIDE2

Obiectiv IR cu unghi larg

 

FLK-LENS/25MAC2

Obiectiv IR macro, 25 microni

 

 

More products FLUKE

INTRINSICALLY SAFE PRESSURE CALIBRATOR FLUKE 718

• ATEX II 1G Ex ia IIC T4 Compliant
• Built-in pressure / vacuum hand pump
• Pressure measurement to 0.05%
• Pressure measurement to 200

 

MULTIFUNCTION PROCESS CALIBRATOR FLUKE 725

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

ELECTRIC PRESSURE CALIBRATOR FLUKE 719

• Best in class pressure measurement uncertainty of 0.025%
• Measure and source mA with best in class 0.015% accuracy
• 30 PSI and 100 PSI pressure ranges

 

FLUKE TIS55 INFRARED CAMERA 220X165

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE TOPAS 1760 THREE PHASE POWER QUALITY RECORDER

• 8 input channels
• Fully IEC 61000-4-30 Class-A standard compliant
• Power quality statistics according to EN50160, DISDIP tables, ITIC, CEBEMA, ANSI
• 10 MHz, 6000 Vpk waveform capture
• GPS time synchronization
• records rms, min, max values for: Voltage Current Power P, Q, S Power Factor kWh Flicker Unbalance Frequency Harmonics Interharmonics

 

WIRELESS AC VOLTAGE MODULE FLUKE CNX V3000

• True-RMS AC voltage measurements to 1000V
• ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT IV 600 V, CAT III 1000 V; IP42


VIBRATION METER FLUKE 805

• measures overall vibration as well as specific variables like bearing condition and temperature
• calculate bearing condition and overall vibration
• Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz)
• Exportable data via USB
• Crest Factor+

 

FLUKE 719PRO ELECTRIC PRESSURE CALIBRATOR

• Fluke-719Pro-30G -12 to 30 PSI / -0.8 to 2 bar
• Fluke-719Pro-150G -12 to 150 PSI / -0.8 to 10 bar
• Fluke-719Pro-300G -12 to 300 PSI / -0.8 to 20 bar
• Unique integrated electric pump for one handed pressure calibration
• Pressure measurement from internal or external sensor
• Sourced/simulated or measured mA values
• Temperature measured by optional RTD probe

 

VOLTAGE DETECTOR FLUKE LVD1 VOLT LIGHT

• Detects voltages from 40 V AC to 300 V AC
• Non-contact AC voltage detector and LED flashlight
• exclusive dual-sensitivity

 

INTERNAL BATTERY RESISTANCE ANALYZER FLUKE BT520

• Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
• Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
• Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
• Wireless communication
• USB Port