FLUKE TiX520 Infrared Camera 320x240

Code: FLUKE TiX520


 

Datasheet PDF, 1.8 Mb

Description

Models:
 

Fluke TiX500 320x240 pixels, -20 °C..+650 °C

Fluke TiX520 320x240 pixels, -20 °C..+850 °C

Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 
 

Fluke TiX520 Infrared Camera

 
 

 

 

  • The largest 5.7 inch responsive LCD touchscreen for a 320x240 infrared camera
  • 180° articulating lens for those tough shots
  • Premium image quality with leading spatial resolution for a 320x240 infrared cameraš
  • Get up to 4 times the resolution and pixels than standard mode with SuperResolution (up to 307,200 pixels)
  • LaserSharp® Auto Focus - utilizing precision laser technology, focus on your target with pinpoint accuracy and get the correct image and temperature measurements you need
  • Built-in laser distance meter - calculates the distance to your designated target up to 100 feet (30 meters) and displays the distance on the image
  • Quick and easy in-field analysis with IR-Fusion® technology and advanced touchscreen functions:
    • Continuous level and span adjustment 
    • Filter mode for improved thermal sensitivity
  • Post capture image editing includes:
    • Emissivity
    • Background temperature
    • Transmissivity
    • Palettes
    • Color alarms
    • IR-Fusion
    • Enable/disable markers
  • Connect to the largest network of wireless test and measurement tools with Fluke Connect™ (not available in all countries)
  • Temperature measurements up to 850 °C
  • Light and ergonomic design with neck and hand strap for all day use
  • Optional field installable wide angle and telephoto lenses

 

 

 
 

Standard accessories

  • Thermal imager with standard infrared lens
  • Ac power supply and battery pack charger (including universal ac adapters)
  • Two, rugged lithium ion smart battery packs
  • USB cable
  • HDMI video cable
  • Bluetooth headset (where available)
  • Rugged, hard carrying case
  • Adjustable neck and hand strap
  • Flash drive with SmartView® Software and user manual
  • Warranty registration card and calibration certificate

 

 

 

Recommended options

FLK-LENS/TELE2

2 teleobiective IR

 

FLK-LENS/4XTELE2

4 teleobiective IR

 

BOOK-ITP

Introducere în principiile termografiei

 

FLK-LENS/WIDE2

Obiectiv IR cu unghi larg

 

FLK-LENS/25MAC2

Obiectiv IR macro, 25 microni

 

 

More products FLUKE

FLUKE 6303A LCR METER 1 KHZ

• 1 kHz test frequency
• 0.25% accuracy
• test signal level: 2V via 400O source

 

CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 375

• iFlex fexible current probe compatible
• 600 A AC and DC current measurement with fxed jaw
• 2500 A AC current measurement with iFlex (sold separately)
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60 k O resistance measurement
• 500 mV dc measurement range
• 1000 µF capacitance measurement

 

DOCUMENTING PROCESS CALIBRATOR-HART FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement
• HART Capabilities

 

FLUKE VR1710 SINGLE PHASE VOLTAGE QUALITY RECORDER

• 70 V to 300 V Operating Voltage
• Fast and easy recording of voltage trends, dropouts, and power quality
• Continuous recording of all values with no gaps
• Flicker recording to EN 61000-4-15, individual harmonic and THD values
• Min, Max, and Average RMS values


THERMOCOUPLE TEMPERATURE CALIBRATOR FLUKE 714

• -200 to 1800ēC Range Measure / simulate thrmocouple
• -10 to 75 mV Range Measure / simulate voltage
• Measure temperature from TC output

 

FLUKE 1621 EARTH GROUND TESTER

• 3-pole Fall-of-Potential earth testing for basic measurements
• 2-pole resistance measurements for added versatility
• 600 V Cat II

 

VOLTAGE DETECTOR FLUKE 1AC II VOLTALERT

• CAT IV 1000 V for added protection
• 200 V to 1000 V AC

 

MULTIFUNCTION PROCESS CALIBRATOR FLUKE 726

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 O Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

FLUKE 115 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• AC/DC Current
• Capacitance and Frequency

 

FLUKE 438 II MOTOR AND ENERGY QUALITY ANALYZER

• Measure key parameters on direct-on-line motors including torque, RPM, mechanical power and motor efficiency
• Perform dynamic motor analysis by plotting of motor derating factor against load according to NEMA/IEC guidelines
• Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and you're ready to go
• Measure electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency