Documenting Process Calibrator Fluke 741B

Code: Fluke 741B


 

Datasheet PDF, 0.13 Mb

Description

  • 0 to 300 V DC/AC Voltage measure
  • 0 to 15 V DC Voltage source / simulate
  • 0 to 110 mA DC Current measure
  • 0 to 22 mA DC Current  source / simulate
  • 0 to 11 kO Resistance measure / source / simulate
  • 1 to 50 kHz Frequency measure / source / simulate
  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Measure and source simultaneously with one compact, rugged, reliable tool
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white display. Read both sourced and measured parameters
  • Multi lingual interface
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1msec.
 

Standard accessories

  • BC7217 battery charger
  • BP7217 battery pack
  • Instruction manual
  • NIST-traceable calibration report and data
  • One set of TP220 test probes
  • Two sets of AC220 test clips
  • Two sets of TL224 industrial test leads
  •  

    More products FLUKE

    BATTERY RESISTANCE ANALYZER FLUKE BT521

    • Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
    • Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
    • Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
    • Wireless communication
    • USB Port

     

    DIGITAL CONTACT THERMOMETERS SERIES FLUKE 50 II

    • Relative time clock on MIN, MAX, and AVG provides a time reference for major events
    • Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
    • Measures J, K, T, and E-types of thermocouples
    • Readout in ºC, ºF, or Kelvin (K)
    • Data Logging up to 500 points of data with user adjustable recording interval(Fluke 53 II and Fluke 54 II)

     

    CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 375

    • iFlex fexible current probe compatible
    • 600 A AC and DC current measurement with fxed jaw
    • 2500 A AC current measurement with iFlex (sold separately)
    • 600 V AC and DC voltage measurement
    • True-rms AC voltage and current
    • Frequency measurement to 500 Hz
    • 60 k O resistance measurement
    • 500 mV dc measurement range
    • 1000 µF capacitance measurement

     

    FLUKE 115 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

    • 3.5 digit
    • 6000 count
    • 0.5% accuracy
    • AC/DC Current
    • Capacitance and Frequency

     

    INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

    • 0 to 100 mV, 0 to 30 V DC Voltage measure
    • 0 to 100mV, 0 to 10 V DC Voltage source / simulate
    • 0 to 24 mA Current measure / source / simulate
    • 0 to 3200 O Resistance measure / source / simulate
    • 1 to 10 kHz Frequency measure / source / simulate
    • RTDs, thermocouples measure / source / simulate
    • pressure measure
    • ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

     

    TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 323

    • 400 A ac current measurement
    • 600 V ac and dc voltage measurement
    • True-rms ac voltage and current for accurate measurements on non-linear signals
    • Resistance measurement up to 40 k? with continuity detection

     

    FLUKE VT02 INFRARED THERMOMETER WITH INTEGRATED CAMERA

    • take simultaneous visual images with the thermal heat map images that are accurately aligned close in
    • Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
    • Infrared spectral band 6.5 µm to 14 µm
    • Minimum focus distance 50 cm (19.6 in)
    • Field of View 20° X 20°
    • 4 GB Micro SD card

     

    POWER QUALITY CLAMP METER FLUKE 345

    • 2000A AC/DC current
    • 600 V CAT IV power analyzer
    • Data logging
    • Troubleshoot harmonics
    • Inrush current

     

    TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 324

    • 400 A ac current measurement
    • 600 V ac and dc voltage measurement
    • True-rms ac voltage and current for accurate measurements on non-linear signals
    • Resistance measurement up to 40 k? with continuity detection
    • Temperature and capacitance measurement

     

    FLUKE 6306 AUTOMATIC RCL METER 50 HZ..1 MHZ

    • 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
    • 100 kHz to 1 MHz (1 kHz steps) test frequencies
    • 0.1 % basic accuracy
    • Easy to use, at-a-glance display