Leakage Current Clamp Meter AC 60A Fluke 360

Code: Fluke 360


 

Datasheet PDF, 0.51 Mb

Description

  • Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion
  • Broad range of measurement, from 1 µA up to 60 A, for all installation needs
  • Advanced shielding to ensure accurate results when measuring near other conductors
  • The high durability clamp construction can withstand over 50,000 operations, added ruggedness that extends the life of your leakage clamp.
  • Easy-to-carry, pocket-sized leakage current tester with wide 40 mm (1.5 in) jaw size
  • Handy "Display-Hold" button for capturing leakage current readings in hard-to-reach places
  • Auto power-off, with warning buzzer, saves battery life
  • Conformance to IEC1010 and EMC standard for confident measurements
  • Meets all of the applications and performance classes in safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances
 

Standard accessories

  • Soft carrying pouch
  • Users manual
 

More products FLUKE

UNIVERSAL CALIBRATOR FLUKE 9100

• Calibrates over 15 different categories of general-purpose test equipment
• Options for power meter, insulation/continuity tester and oscilloscope calibration
• Semi-automated and fully automated procedure modes
• Fully supported by MET/CAL Plus software
• Intuitive front panel operation for ease of use

 

VOLTAGE DETECTOR FLUKE 1AC II VOLTALERT

• CAT IV 1000 V for added protection
• 200 V to 1000 V AC

 

LASER DISTANCE METER 50M FLUKE 414D

• Instantly measures up to 50m (165 feet) with one button
• Laser accuracy of +/- 2mm (0.08 in)
• Easy, automatic math for area and volume, add and subtract with ease

 

FLUKE 8846A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0024 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution

 

FLUKE 115 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• AC/DC Current
• Capacitance and Frequency

 

FLUKE 712B RTD TEMPERATURE CALIBRATOR

• measure and simulate (13) different RTD types and resistance
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

BATTERY RESISTANCE ANALYZER FLUKE BT521

• Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
• Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
• Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
• Wireless communication
• USB Port

 

FLUKE 700HTP-2 HYDRAULIC TEST PUMP FOR PRESSURE CALIBRATION

• hand operated hydraulic pressure pump
• designed to generate calibration pressures up to 10,000 psi/690 bar
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Improved priming
• Improved stroke limiting mechanism

 

FLUKE 43B POWER QUALITY ANALYZER

• Power Quality Analyzer Measures power (W, VA, VAR) and power factor (PF, DPF)
• Oscilloscope Dual-channel scope 20 MHz bandwidth
• Multimeter
• Recorder
• Harmonics Up to 51st
• Power One and three phase

 

FLUKE 287 HANDHELD DIGITAL DATA LOGGING MULTIMETER 4.5 DIGIT

• 4.5 digit large ¼ VGA display with white backlight
• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture