Quad-Ridged Open Boundary Horn Antenna 700 MHz..10 GHz ETS-Lindgren 3164-08

Code: ETS-Lindgren 3164-08


 

Datasheet PDF, 0.36 Mb

Description

  • Frequency Minimum     700 MHz
  • Frequency Maximum    10 GHz
  • Cross Polarization Isolation       >20 dB
  • Impedance       50 ?
  • Connector Input Power            SMA Female (2)
  • 700 MHz - 10 GHz Frequency Range
  • Linear or Circular Polarization (With Hybrid)
  • Low VSWR with Improved Gain
  • Compact Design
  • Flexible Mounting Schemes
  • --Standard Tripod Mounting Flange
  • --Optional Wall Mounting Plate
  • Maintains Shielding Integrity when Wall Mounted with Optional Mounting Plate
  • Excellent Gain Over Entire Range
 

More products ETS-LINDGREN

FIELD GENERATING PYRAMIDAL HORN ANTENNA FOR EMC AUTOMOTIVE TESTING ES-XW7T-1A278-AC 2.7..3.1 GHZ ETS-LINDGREN 3162-02

• Frequency Minimum 2.7 GHz
• Frequency Maximum 3.1 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Polarization linear
• Meets Specs for ES-XW7T-1A278-AC

 

WLAN ACCES POINT TEST ENCLOSURE ETS-LINDGREN 5225

• Works with 802.11 Traffic Generator and Performance Analyzers
• Tests:
• -- Over-The-Air Performance of TX, RX
• -- Wireless LAN Access Point Throughput Performance
• Flat Coupling Response over 2.2GHz - 2.6GHz, 5.2GHz - 6.0GHz

 

MONAXIAL HELMHOLTZ COIL WITH LOW FREQUENCY UNIFORM MAGNETIC FIELD

• Excellent for Magnetic Immunity Testing
• A Source for Calibration
• Custom Models Available

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION WITH LOW EARTH LEAKAGE CURRENTS 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

LINE IMPEDANCE STABILIZATION NETWORK ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience


HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BROADBAND LOG PERIODIC ANTENNA FOR CISPR 16-1 TEST 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear