Biconical Antenna for Testing IEC 1000-4-3 20..300 MHz ETS-Lindgren 3109

Code: ETS-Lindgren 3109


 

Datasheet PDF, 1.8 Mb

Description

  • Frequency Minimum     20 MHz
  • Frequency Maximum    300 MHz
  • Connectors       Type N (f)
  • Impedance (Nominal)   50 ?
  • Maximum Continuous Power    2 kW
  • Pattern Type     omnidirectional
  • Peak Power     3 kW
  • Polarization       linear
  • VSWR 1.9:1
  • Power Handling Capability Up to 3 kW
  • Unique Element Design Improves Performance
  • Compact Size for Use in Limited Space
  • Improved Balun Design for Increased Efficiency
  • Quality Construction for Trouble-Free Service
 

More products ETS-LINDGREN

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

ACTIVE RECEIVING LOOP SHIELDED ANTENNA 1 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 10 V/m
• Connectors BNC (f)
• Dynamic Range 116 dB @ 1 MHz , 76 dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

ELECTRIC & MAGNETIC FIELD RF INDUSTRIAL COMPLIANCE TESTER 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

CONICAL LOG SPIRAL ANTENNA 200 MHZ..1 GHZ ETS-LINDGREN 3101

• Frequency Minimum 200 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 150 W
• Polarization circular
• VSWR 2.4:1
• Extremely low VSWR
• Individually calibrated

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 2..18 GHZ ETS-LINDGREN 3164-05

• Frequency Minimum 2 GHz
• Frequency Maximum 18 GHz
• Connectors SMA Female
• Cross Polarization Isolation >24 dB
• Impedance (Nominal) 50 ?
• Maximum Power 25 W
• Pattern Type directional
• Polarization dual linear

 

BROADBAND OMNIDIRECTIONAL ANTENNA FOR SPECTRUM MONITORING 500 MHZ..18 GHZ ETS-LINDGREN 3181

• Frequency Minimum 500 MHz
• Frequency Maximum 18 GHz
• Connectors SMA (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 200 watts @ 500 MHz, 25 watts @ 18 GHz

 

LINEAR POLARIZED LOG PERIODIC ARRAY ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

EMI POWER FILTERS IN TEMPEST/ EMC SYSTEM SINGLE LINE NETWORK 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4