EMI Power Filters in Tempest/ EMC system single line network 32..120A ETS-Lindgren N192X

Code: ETS-Lindgren N192X


 

Datasheet PDF, 1.02 Mb

Description

  • Current Range 32 to 250 Amperes
  • Very High RF Attenuation
  • Fully Tested for Attenuation Performance
  • Durable Construction
  • CE Marked

 

APPLICATIONS

  • In high performance screened rooms, providing sufficient attenuation of both the incoming and outgoing mains supply lines to match the shield performance.
  • In TEMPEST applications where the very highest degree of protection is required to obtain maximum security.
  • In EMP protection systems.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Freq. (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz Sys. Per Line (Max)

DC Resistance Per Line (milliohms)

N1923

32

250

DC/50/60

Single

0.6

24

N1923

20

120

400

Single

0.6

24

N1924

63

250

DC/50/60

Single

0.7

9

N1924

40

120

400

Single

0.7

9

N1925

100

250

DC/50/60

Single

0.9

5

N1925

60

120

400

Single

0.9

5

N1926

200

250

DC/50/60

Single

0.9

2.5

N1926

120

120

400

Single

0.9

2.5

N1926/250

250

250

DC/50/60

Single

0.9

2.5

N1926/250

120

120

400

Single

0.9

2.5

 

More products ETS-LINDGREN

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BICONICAL PRECISION MEASUREMENT ANTENNA 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

ELECTROMAGNETIC LEAKAGE METER OF MICROWAVE OVEN ETS-LINDGREN HI-1501

• Three Ranges
• Calibrated at 2450 MHz
• Battery Operated
• Extra sensitivity for Compliance Measurement

 

HYBRID LOG PERIODIC BROADBAND ANTENNA FOR EMC MEASUREMENTS 26 MHZ..3 GHZ ETS-LINDGREN 3140B

• Frequency Minimum 26 MHz
• Frequency Maximum 3 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear
• Best EMC RI Performance

 

ACTIVE MONOPOLE RECEPTION ANTENNA 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

DOUBLE-RIDGED MICROWAVE GUIDE HORN ANTENNA 750 MHZ..18 GHZ ETS-LINDGREN 3115

• Frequency Minimum 750 MHz
• Frequency Maximum 18 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 500 W
• Pattern Type directional
• Polarization linear

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options