EMI Power Filters in Tempest/ EMC system single line network 32..120A ETS-Lindgren N192X

Code: ETS-Lindgren N192X


 

Datasheet PDF, 1.02 Mb

Description

  • Current Range 32 to 250 Amperes
  • Very High RF Attenuation
  • Fully Tested for Attenuation Performance
  • Durable Construction
  • CE Marked

 

APPLICATIONS

  • In high performance screened rooms, providing sufficient attenuation of both the incoming and outgoing mains supply lines to match the shield performance.
  • In TEMPEST applications where the very highest degree of protection is required to obtain maximum security.
  • In EMP protection systems.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Freq. (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz Sys. Per Line (Max)

DC Resistance Per Line (milliohms)

N1923

32

250

DC/50/60

Single

0.6

24

N1923

20

120

400

Single

0.6

24

N1924

63

250

DC/50/60

Single

0.7

9

N1924

40

120

400

Single

0.7

9

N1925

100

250

DC/50/60

Single

0.9

5

N1925

60

120

400

Single

0.9

5

N1926

200

250

DC/50/60

Single

0.9

2.5

N1926

120

120

400

Single

0.9

2.5

N1926/250

250

250

DC/50/60

Single

0.9

2.5

N1926/250

120

120

400

Single

0.9

2.5

 

More products ETS-LINDGREN

ELECTRIC & MAGNETIC FIELD RF INDUSTRIAL COMPLIANCE TESTER 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

CONICAL LOG SPIRAL ANTENNA 1..10 GHZ ETS-LINDGREN 3102

• Frequency Minimum 1 GHz
• Frequency Maximum 10 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 50 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Extremely low VSWR

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

BROADBAND BICONICAL ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

BROADBAND LOG PERIODIC ARRAY ANTENNA 200 MHZ..5 GHZ ETS-LINDGREN 3147

• Frequency Minimum 200 MHz
• Frequency Maximum 5 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 80 W
• Pattern Type directional
• Peak Power 100.0 W
• VSWR 1.2:1

 

WIRELESS INTERFACE TEST SYSTEM FOR MOBILE PHONE TESTING IN CELLULAR COMMUNICATIONS ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1 GHz, 25 watts @ 18 GHz
• Broadband Spectrum Monitoring
• Harmonics Level Measurement IEC 61000-4-3

 

LINE IMPEDANCE STABILIZATION NETWORK ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience