EMI Power Filters in Tempest/ EMC system single line network 32..120A ETS-Lindgren N192X

Code: ETS-Lindgren N192X


 

Datasheet PDF, 1.02 Mb

Description

  • Current Range 32 to 250 Amperes
  • Very High RF Attenuation
  • Fully Tested for Attenuation Performance
  • Durable Construction
  • CE Marked

 

APPLICATIONS

  • In high performance screened rooms, providing sufficient attenuation of both the incoming and outgoing mains supply lines to match the shield performance.
  • In TEMPEST applications where the very highest degree of protection is required to obtain maximum security.
  • In EMP protection systems.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Freq. (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz Sys. Per Line (Max)

DC Resistance Per Line (milliohms)

N1923

32

250

DC/50/60

Single

0.6

24

N1923

20

120

400

Single

0.6

24

N1924

63

250

DC/50/60

Single

0.7

9

N1924

40

120

400

Single

0.7

9

N1925

100

250

DC/50/60

Single

0.9

5

N1925

60

120

400

Single

0.9

5

N1926

200

250

DC/50/60

Single

0.9

2.5

N1926

120

120

400

Single

0.9

2.5

N1926/250

250

250

DC/50/60

Single

0.9

2.5

N1926/250

120

120

400

Single

0.9

2.5

 

More products ETS-LINDGREN

PROTECTION TEMPEST/ RFI/ EMI FILTERS FOR TELECOM ETS-LINDGREN N24X/ N29X

• Suitable for EMI, EMP and Tempest protection
• Tubular, flat-pack or modular design
• 100dB insertion loss
• New ISDN filters now available
• Matched to balanced 600 Ohm lines

 

WLAN ACCES POINT TEST ENCLOSURE ETS-LINDGREN 5225

• Works with 802.11 Traffic Generator and Performance Analyzers
• Tests:
• -- Over-The-Air Performance of TX, RX
• -- Wireless LAN Access Point Throughput Performance
• Flat Coupling Response over 2.2GHz - 2.6GHz, 5.2GHz - 6.0GHz

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

PORTABLE TEST ENCLOSURE FOR EMI/RFI TEST ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

PRECISION DIPOLE ANTENNA WITH OMNI-DIRECTIONAL EMISSIONS FOR IMMUNITY TESTING 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements

 

BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1 GHz, 25 watts @ 18 GHz
• Broadband Spectrum Monitoring
• Harmonics Level Measurement IEC 61000-4-3

 

BROADBAND BICONICAL ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3182

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 200 watts

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA FOR EMC MEASUREMENTS 400 MHZ..6 GHZ ETS-LINDGREN 3119

• Frequency Minimum 400 MHz
• Frequency Maximum 6 GHz
• VSWR Ratio (AVG) 3.5:1 max
• <2:1 above 500 MHz
• Maximum Continuous Power 1500 W @ 400 MHz, 800 W @ 6 GHz
• Peak Power 2500 W

 

BROADBAND BICONICAL ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 30 HZ..100 KHZ ETS-LINDGREN 7605/ 7606

• Frequency Minimum 30 Hz
• Frequency Maximum 100 kHz
• Connectors Banana Jack (2) - [7605], BNC - [7606]
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear