GTEM Test Cell for EMC Radiated Emissions & Immunity ETS-Lindgren 5402

Code: ETS-Lindgren 5402


 

Datasheet PDF, 0.12 Mb

Description

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f < 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

50 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq < 1.50:1
Characteristic Freq < 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Standard accessories

  • Manual emissions correlation software (on request)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • 5400 GTEM! Series manual
  • One removable access port in floor
  • ETS-Lindgren absorber material
  • Primary door 6.3" W x 9.1" H clear opening (16 cm x 23 cm)
  • Completely assembled
 

Recommended options

  • Blank connector panel
 

More products ETS-LINDGREN

BICONICAL PRECISION MEASUREMENT ANTENNA 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

BROADBAND LOG PERIODIC ANTENNA FOR CISPR 16-1 TEST 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

LINEAR POLARIZED LOG PERIODIC HIGH POWER DUAL ARRAY ANTENNA 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2

 

PORTABLE TEST ENCLOSURE FOR EMI/RFI TEST ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

BROADBAND BICONICAL ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

PRECISION DIPOLE ANTENNA WITH OMNI-DIRECTIONAL EMISSIONS FOR IMMUNITY TESTING 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements