High Performance Power Filters for Tempest/ EMI/ EMC test currents 16..200A ETS-Lindgren N500X

Code: ETS-Lindgren N500X


 

Datasheet PDF, 1.12 Mb

Description

  • Maximum protection in Tempest and EMPP applications
  • Highest performing commercially available power line filter
  • Over 100dB insertion loss from 10 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • Low power dissipation
  • Compact Rugged Construction
  • 100dB insertion loss from 40kHz
  • Suitable for 400Hz supplies
  • Current Range 16 to 200 Amperes

 

APPLICATIONS

  • In high performance screened rooms and anechoic chambers the N500X series provides protection of both incoming and outgoing supplies in line with the shield performance.
  • In TEMPEST applications, the N500X filters provide an extremely high degree of protection required to obtain maximum security.
  • N500X filters are ideal for EMC applications such as computer suites.
  • N500X filters can be used for general purpose high performance filtering.
 
 
 Electrical Specifications
 

PART #

Current Max (Amps)

Voltage Max (Volts)

Frequency (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60Hz System per Line (Max)

Full Load Dissipation

5000

16

250

DC/50/60/400

2

1.3

20

5001

16

440/250

DC/50/60/400

4

0.65

20

5002

32

250

DC/50/60/400

2

0.3

20

5003

32

440/250

DC/50/60/400

4

0.15

20

5004

63

250

DC/50/60/400

2

0.4

48

5005

63

440/250

DC/50/60/400

4

0.2

48

5006

100

250

DC/50/60/400

2

0.3

60

5007

100

440/250

DC/50/60/400

4

0.15

60

5008

200

250

DC/50/60/400

2

0.2

80

5009

200

440/250

DC/50/60/400

4

0.1

80

  • High performance screen rooms, providing attenuation of both the incoming and outgoing mains supply lines to match the shield performance
  • Tempest applications, where the very highest degree of protection is required to obtain maximum security
  • EMP protection systems

 

Electrical Specifications

Part #

Current Max

Frequency

Max Voltage

# of Lines

Voltage Drop On Full Load in 250V 50/50Hz System/Line

DC Resistance Per Line

N2550

6 A

50/60 Hz

250 V

2

1 V

50 O

N2551

6 A

50/60 Hz

440/250 V

4

1 V

50 O

N2552

16 A

50/60 Hz

250 V

2

1 V

12 O

N2553

16 A

50/60 Hz

440/250 V

4

1 V

12 O

N2554

32 A

50/60 Hz

250 V

2

0.6 V

24 O

N2555

32 A

50/60 Hz

440/250 V

4

0.6 V

24 O

N2556

63 A

50/60 Hz

250 V

2

1.5 V

15 O

N2557

63 A

50/60 Hz

440/250 V

4

1.5 V

15 O

N2558

100 A

50/60 Hz

250 V

2

0.9 V

5 O

N2559

100 A

50/60 Hz

440/250 V

4

0.9 V

5 O

 

More products ETS-LINDGREN

BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1 GHz, 25 watts @ 18 GHz
• Broadband Spectrum Monitoring
• Harmonics Level Measurement IEC 61000-4-3

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

BROADBAND BICONICAL ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

MULTI-OCTAVE PYRAMIDAL HORN ANTENNA LINEAR POLARIZED 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear

 

UNIVERSAL SPHERICAL DIPOLE EMI RADIATION SOURCE ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

ACTIVE RECEIVING LOOP ANTENNA 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

ELECTROMAGNETIC LEAKAGE METER OF MICROWAVE OVENS ETS-LINDGREN HI-1600

• Calibrated at 915 MHz and 2450 MHz
• Three Ranges

 

MAGNETIC FIELD GENERATING COIL ANTENNA 20 HZ..50 KHZ ETS-LINDGREN 7603

• Frequency Minimum 20 Hz
• Frequency Maximum 50 kHz
• Connectors Banana Jack (2)
• Impedance (Nominal) 50 ?
• Maximum Input Power 5 A
• Pattern Type omnidirectional
• Polarization linear

 

ACTIVE MONOPOLE RECEPTION ANTENNA 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge