Magnetic Dipole Antenna for Ripple Test Measurement in Cellular Telecommunication & CTIA Internet 440..2665 MHz ETS-Lindgren 3127

Code: ETS-Lindgren 3127


 

Datasheet PDF, 0.07 Mb

Description

  • Range of Frequencies to Cover Wireless Device Bands: 440...2665 MHz
  • Designed for CTIA Ripple Test
  • Meet CTIA +/- 0.1 dB Symmetry Requirement

 

Electrical Specifications

Model

Frequency

Connectors

Impedance (Nominal)

Max Cont. Power

VSWR

3127-450

440 MHz - 460 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-700

690 MHz - 710 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-850

840 MHz - 860 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-880

870 MHz - 890 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-920

910 MHz - 930 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1575

1565 MHz - 1585 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1732

1722 MHz - 1742 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1768

1758 MHz - 1778 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1790

1780 MHz - 1800 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1800

1790 MHz - 1810 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1862

1852 MHz - 1872 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1880

1870 MHz - 1890 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-1950

1940 MHz - 1960 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-2150

2140MHz - 2160 Mhz

SMA Female

50 O

1 W

<5:1 Typical

3127-2450

2440MHz - 2460 Mhz

SMA Female

50 O

1 W

<5:1 Typical

3127-2535

2525 MHz - 2545 MHz

SMA Female

50 O

1 W

<5:1 Typical

3127-2655

2645 MHz - 2665 MHz

SMA Female

50 O

1 W

<5:1 Typical

Physical Specifications

Model

Diameter A

Diameter B

Length

3127-450

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-700

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-850

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-880

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-920

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1575

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1732

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1768

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1790

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1800

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1862

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1880

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-1950

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-2150

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-2450

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-2535

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

3127-2655

1.9 cm   (0.75 in)

12.70 cm   (5.00 in)

21.59 cm   (8.50 in)

 

More products ETS-LINDGREN

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

HYBRID LOG PERIODIC BROADBAND ANTENNA FOR EMC MEASUREMENTS 80 MHZ..6 GHZ ETS-LINDGREN 3149

• Frequency Minimum 80 MHz
• Frequency Maximum 6 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 750 W..200 W
• Pattern Type directional
• Polarization linear
• VSWR 6.5:1 max

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

BROADBAND LOG PERIODIC ANTENNA FOR CISPR 16-1 TEST 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

ELECTROMAGNETIC LEAKAGE METER OF MICROWAVE OVEN ETS-LINDGREN HI-1501

• Three Ranges
• Calibrated at 2450 MHz
• Battery Operated
• Extra sensitivity for Compliance Measurement

 

RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

CONICAL LOG SPIRAL ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3103

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Two Year Warranty
• Extremely low VSWR

 

MULTI-OCTAVE PYRAMIDAL HORN ANTENNA LINEAR POLARIZED 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear