Portable Test Enclosure for EMI/RFI Test ETS-Lindgren 5240

Code: ETS-Lindgren 5240


 

Datasheet PDF, 0.37 Mb

Description

  • Ease of operation in a compact, portable format
  • Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
  • High performance 24 ounce copper shielding construction
  • Shielding performance of 120 dB+

 

Test Cell Specifications

Model

Construction

Dimensions (O/D) LxWxH

Opening Dimensions

RF Seal Type

5240-18

24 oz copper clad exterior

450x450 mm/ Dec Type

250x250 mm/ DEC Type

Double Electrical Contact

5240-24

24 oz copper clad exterior

600 x 600 x 600 mm

450 x 450 mm / DEC Type

Double Electrical Contact

5240-30

24 oz copper clad exterior

750x750x750 mm

600x600 mm/ DEC Type

Double Electrical Contact

5240-36

24 oz copper clad exterior

900 x 900 x 900 mm

600 x 600mm / DEC Type

Double Electrical Contact

5240-48

24 oz copper clad exterior

1200 x 1200 x 1200 mm

900 x 900 mm / DEC Type

Double Electrical Contact

5240-2442

24 oz copper clad exterior

600 x 1050 x 600 mm

450 x 450 mm / DEC Type

Double Electrical Contact

5241-12

24 oz copper clad exterior

300x300x300 mm

250x250 mm/ Plate Type

Finger stock

5245

Aluminum, welded seam

430x430x430 mm

450x450 mm/ Plate Type

Finger stock

5247

Series 81 construction

890 x 890 x 1830 mm

450 x 450 mm / Plate Type

Finger Stock

5249

Stainless steel welded seam

255 x 300 x 150 mm

Shielded Lid

Finger stock

 

Standard accessories

 

 

Recommended options

  • Connector plate bulkhead penetrations
  • Waveguide feedthroughs
  • Exhaust fan for air circulation and heat dissipation
  • Fiber optic packages
  • High performance ferrite tile lining
  • RF foam absorber lining
  • High performance door upgrade
 

More products ETS-LINDGREN

MAGNETIC FIELD MEASUREMENT PROBE 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection

 

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

BROADBAND LOG PERIODIC ANTENNA FOR CISPR 16-1 TEST 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B

• Frequency Minimum 200 MHz
• Frequency Maximum 2.5 GHz
• Connectors Type N (f)
• Impedance (Nominal) 1600 W
• Maximum Continuous Power 800 W
• Pattern Type directional

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

ACTIVE RECEIVING LOOP ANTENNA 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 30 HZ..100 KHZ ETS-LINDGREN 7605/ 7606

• Frequency Minimum 30 Hz
• Frequency Maximum 100 kHz
• Connectors Banana Jack (2) - [7605], BNC - [7606]
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

E-FIELD GENERATOR LINEAR POLARIZED 10 KHZ..30 MHZ ETS-LINDGREN 3107B

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1000 W
• Peak Power 1500 W
• Polarization linear
• Linear Polarization

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear