High Current Power RFI/EMI Protection Filters in single phase network 400..800A ETS-Lindgren N2510

Code: ETS-Lindgren N2510


 

Datasheet PDF, 0.3 Mb

Description

  • >3000 Amp capability
  • Fully accessible end chambers
  • 80 dB Insertion Loss From 100 kHz to 10 GHz
  • Excellent strength to weight ratio
  • RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
  • High current capability
  • Compact design

  

Applications

  • High current power circuits
  • EMP installations

 

DC Resistance Per Line

0.15 ? - 0.15 ?

Case Temp Rise On Full Load

+20 °C - +20 °C

Current Max

800 A - 400 A

Frequency

50/60 Hz - 400 Hz

Full Load Dissipation

1.3 KW - 1.3 KW

Max. Recom. Case Temp On Full Load

+70 °C - +70 °C

No. of Lines

1 - 1

Series Inductance Per line

8.75 uH - 8.75 uH

Shunt Capacitance Per Line

64 uF - 64 uF

Voltage Drop on Full Load in 350V 50/60Hz System/Line

3 V - 3 V

Voltage Frequency Maximum

440/250 - 120

 

More products ETS-LINDGREN

BICONICAL ANTENNA FOR TESTING IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA FOR EMC MEASUREMENTS 1..18 GHZ ETS-LINDGREN 3117

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Peak Power 400 W
• Polarization linear

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

HYBRID LOG PERIODIC BROADBAND ANTENNA FOR EMC MEASUREMENTS 80 MHZ..6 GHZ ETS-LINDGREN 3149

• Frequency Minimum 80 MHz
• Frequency Maximum 6 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 750 W..200 W
• Pattern Type directional
• Polarization linear
• VSWR 6.5:1 max

 

RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

MAGNETIC FIELD MEASUREMENT PROBE 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection

 

PROTECTION FILTERS FOR TEMPEST/ RFI/ EMI DIGITAL ANALOG DATA TRANSMISSIONS ETS-LINDGREN N2460

• Suitable for EMI and Tempest Protection
• Digital and analogue transmissions
• Tubular, flat-pack or modular design

 

ACTIVE RECEIVING LOOP ANTENNA 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

FIELD GENERATING PYRAMIDAL HORN ANTENNA FOR EMC AUTOMOTIVE TESTING ES-XW7T-1A278-AC 2.7..3.1 GHZ ETS-LINDGREN 3162-02

• Frequency Minimum 2.7 GHz
• Frequency Maximum 3.1 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Polarization linear
• Meets Specs for ES-XW7T-1A278-AC