Reverberation Test Cell for Radiated Immunity and Emissions Measurements ETS-Lindgren Smart 1000

Code: ETS-Lindgren Smart 1000


 

Datasheet PDF, 0.1 Mb

Description

  • Automated Measurement with Optional Software
  • Field Uniformity Better than 3 dB Over Operating Range
  • Compact Bench-Top Design
  • Frequency Range of 1.0 GHz to 40 GHz
  • Radiated Immunity and Emissions Measurements
    IEC61000-4-21
    MIL-STD-461E
  • Fast Measurement Time
  • Two Year Warranty

 

Electrical Specifications

Frequency Minimum

1.0 GHz

Frequency Maximum

40 GHz

 

Standard accessories

  • Chamber calibration from 1.0 GHz to 40 GHz per IEC 61000-4-21
  • Two Year Warranty
  • One Type N and one Type K connector for horns
  • Two double ridged horn antennas (mounted)
  • One vertical, one horizontal tuner, with stepper motors
  • SMART 1000 Mini-Reverb Assembly
 

Recommended options

  • SMARTImm Immunity software
  • Additional N, SMA, 2.9, 3.5, or Type K connectors
  • SMARTEMI Emissions software
 

More products ETS-LINDGREN

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA FOR EMC MEASUREMENTS 1..18 GHZ ETS-LINDGREN 3117

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Peak Power 400 W
• Polarization linear

 

PRECISION SLEEVE DIPOLE ANTENNA FOR RIPPLE TEST MEASUREMENT IN MOBILE COMMUNICATION & CTIA INTERNET 450..5000 MHZ ETS-LINDGREN 3126

• Range of Frequencies to Cover Wireless Device Bands: 450…5000 MHz
• Meet CTIA +/- 0.1 dB Symmetry Requirement
• Precision Gain for Range Calibration

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMI/ EMC TEST CURRENTS 16..200A ETS-LINDGREN N500X

• Low power dissipation
• Compact Rugged Construction
• 100dB insertion loss from 40kHz
• Suitable for 400Hz supplies
• Current Range 16 to 200 Amperes

 

EMC AND RF MICROWAVE ABSORBERS ETS-LINDGREN

• EMC Anechoic Absorber
• Ferrite Tile Absorber
• FerroSorb FS EMC Absorber
• FerroSorb PS EMC Absorber
• Ultra Broadband Microwave Absorber

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION WITH LOW EARTH LEAKAGE CURRENTS 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

ACOUSTIC TEST ENCLOSURE FOR SMALL DEVICES ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

DUAL POLARIZED LOG PERIODIC ARRAY ANTENNA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized