Reverberation Test Cell for Radiated Immunity and Emissions Measurements ETS-Lindgren Smart 1000

Code: ETS-Lindgren Smart 1000


 

Datasheet PDF, 0.1 Mb

Description

  • Automated Measurement with Optional Software
  • Field Uniformity Better than 3 dB Over Operating Range
  • Compact Bench-Top Design
  • Frequency Range of 1.0 GHz to 40 GHz
  • Radiated Immunity and Emissions Measurements
    IEC61000-4-21
    MIL-STD-461E
  • Fast Measurement Time
  • Two Year Warranty

 

Electrical Specifications

Frequency Minimum

1.0 GHz

Frequency Maximum

40 GHz

 

Standard accessories

  • Chamber calibration from 1.0 GHz to 40 GHz per IEC 61000-4-21
  • Two Year Warranty
  • One Type N and one Type K connector for horns
  • Two double ridged horn antennas (mounted)
  • One vertical, one horizontal tuner, with stepper motors
  • SMART 1000 Mini-Reverb Assembly
 

Recommended options

  • SMARTImm Immunity software
  • Additional N, SMA, 2.9, 3.5, or Type K connectors
  • SMARTEMI Emissions software
 

More products ETS-LINDGREN

BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1 GHz, 25 watts @ 18 GHz
• Broadband Spectrum Monitoring
• Harmonics Level Measurement IEC 61000-4-3

 

ELECTRIC & MAGNETIC FIELD RF INDUSTRIAL COMPLIANCE TESTER 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BROADBAND LOG PERIODIC ARRAY ANTENNA 200 MHZ..5 GHZ ETS-LINDGREN 3147

• Frequency Minimum 200 MHz
• Frequency Maximum 5 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 80 W
• Pattern Type directional
• Peak Power 100.0 W
• VSWR 1.2:1

 

ACOUSTIC TEST ENCLOSURE FOR SMALL DEVICES ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

ELF MAGNETIC FIELD SURVEY METER 30..2000 HZ ETS-LINDGREN HI-3624

• Isotropic Response
• True RMS Detection
• 100dB Dynamic Range
• Low Cost, True RMS Magnetic Field Measurements

 

LOG PERIODIC DIPOLE ARRAY ANTENNA FOR EMC MEASUREMENTS 80 MHZ..2 GHZ ETS-LINDGREN 3144

• Frequency Minimum 80 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW

 

PROTECTION TEMPEST/ RFI/ EMI FILTERS FOR TELECOM ETS-LINDGREN N24X/ N29X

• Suitable for EMI, EMP and Tempest protection
• Tubular, flat-pack or modular design
• 100dB insertion loss
• New ISDN filters now available
• Matched to balanced 600 Ohm lines

 

HIGH GAIN CONICAL HORN ANTENNA WITH LINEAR POLARIZATION 4..26.5 GHZ ETS-LINDGREN 3163

• Conical Shape
• Series Frequency Range: 4 GHz to 26.5 GHz
• High Gain
• Low VSWR

 

INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy