GTEM Test Cell for EMC Radiated Emissions & Immunity ETS-Lindgren 5411

Code: ETS-Lindgren 5411


 

Datasheet PDF, 0.93 Mb

Description

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

1 kW

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq 1.50:1
Characteristic Freq 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Standard accessories

  • Two AC receptacles
  • Forced air ventilation
  • Working supervisor for installation is provided. (Outside North America, call factory)
  • Removable bolt-on feed section
  • Additional maintenance kit
  • Three N-type connectors
  • Customer will need to provide manpower and specific tools
  • Shipped disassembled
  • Air compressor for manipulator brake system
  • Manual emissions correlation software (on request)
  • 5400 GTEM! Series manual
  • 7/16" DIN to type "N" adaptor
  • One fiber optic penetration
  • ETS-Lindgren absorber material
  • One 20 amp, 2 line filter
  • Mobile base with locking casters
  • Blank feed-thru panel without frame
  • Additional copy of emissions correlation software
  • Primary door 27" W x 36.42" H clear opening (68.6 cm x 92.5 cm)
  • Individually characterized with results of TDR and VSWR tests
 

Recommended options

  • Window with frame (added to primary door)
  • Blank feed-thru panel, installed
  • GTEM! Theory and training - 2 days
  • Power distribution box
  • Additional 30 amp filter, three phase
  • Feed-thru panel with 3 "N" connectors and 1 fiber optic penetration, uninstalled
  • Secondary door with window
  • Secondary door without window
  • Blank feed-thru panel, uninstalled, no frame assembly
  • Additional 20 amp filter, single phase
  • Automated manipulator
  • Dual telephone filter (same as RP59001)
  • AC power filter, .5 amps, 120 V
  • High voltage feed section
  • Additional primary door without window
  • Manual manipulator
  • DC power filter with banana jacks
  • Illumination kit
  • Pneumatic brake kit upgrade for manipulators with electric brake systems
  • Additional 30 amp filter, single phase
 

More products ETS-LINDGREN

ACTIVE MONOPOLE RECEPTION ANTENNA 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

BROADBAND E-FIELD MONITORING SYSTEM 10 KHZ..40 GHZ ETS-LINDGREN HI-6100 E-FIELD MONITOR

• HI-6100 Field Monitor with 4 Probe Input Channels
• Large Color LCD Display
• IEEE-488, RS-232, USB Interfaces
• USB & RS232 Interface Modules available for Record & View measurements
• Electric Field Probes for 10 kHz..40 GHz frequencies

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

BICONICAL TRANSMITTING-RECEVING ANTENNA 20..200 MHZ ETS-LINDGREN 3104C

• Frequency Minimum 20 MHz
• Frequency Maximum 200 MHz
• Connectors Type N (f)
• FS-600 High Performance Hybrid Ferrite Tile Polyurethane Dielectric 200 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Pattern Type omnidirectional
• Peak Power 100 W
• Polarization linear

 

UNIFORM VERTICAL ELECTRIC FIELD GENERATOR 10 KHZ..30 MHZ ETS-LINDGREN 5503

• Generates large area uniform vertical electric field
• 10 kHz - 30 MHz frequency range
• Accommodates various EUT sizes with adjustable height feature
• Temperature maintained with external forced-air cooling, and monitored by temperature sensor
• Easy to assemble/disassemble and remove from the chamber

 

LOG PERIODIC DIPOLE ARRAY ANTENNA FOR EMC MEASUREMENTS 80 MHZ..2 GHZ ETS-LINDGREN 3144

• Frequency Minimum 80 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW

 

RF ELECTROMAGNETIC SURVEY METER ETS-LINDGREN HI-2200

• Handstrap & Safety Lanyard Mount
• Optional Fiber Optic Link
• Interchangeable Probe Heads
• Small/Lightweight for minimal field perturbance
• Broadband Frequency Range
• Economical Solution to Broadcast/Telecom Safety Monitoring Needs & Environmental Monitoring

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options