BAUR PHG 70 / PHG 80 portable VLF test system

Code: BAUR PHG 70 / PHG 80 Portable


 

Datasheet PDF, 0.31 Mb

Description

The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.

 

Features:

  • 3 voltage shapes in one device: VLF truesinus®, VLF square wave and DC voltage
  • For medium-voltage cables of up to 50 kV operating voltage
  • Cable testing, fault conditioning, cable sheath testing
 

More products BAUR

BAUR PGK 25 DC HIGH-VOLTAGE TEST DEVICE

• Compact device for DC voltage testing with negative polarity
• Continuously adjustable output voltage
• Perfect for mobile use

 

BAUR CL 20 CABLE LOCATOR

• Fast and exact location of position and laying depth of cables
• Intuitive operation ½ no special measurement knowledge required
• Lightweight and manageable

 

BAUR TG 600 AUDIO FREQUENCY TRANSMITTER

• High-performance audio frequency transmitter up to 600 VA
• Frequency of 2 or 10 kHz, quartz-stabilised (other frequencies on request)
• Potential-free output
• Impedance adjustment in 8 steps from 0.3 to 300 O

 

BAUR FRIDA VLF TESTING AND DIAGNOSTICS UNIT

• Precise and non-destructive determination of the cable condition
• Easy and quick test setup
• Automatic testing and diagnostic sequences
• Compact dimensions and lightweight

 

BAUR PGK 110/5 HB HIGH-VOLTAGE TEST DEVICE

• Testing as DC or Dc testing device
• Polarity of the DC voltage can easily be reversed
• Robust and durable

 

BAUR PHG 70 TD PD / PHG 80 TD PD VLF TEST AND DIAGNOSTICS SYSTEM

• Compact, enclosed design in 19½ format
• Variable installation option with separate control and voltage unit
• Variable connection options to cable stations of different models

 

BAUR PGK 110 HB HIGH-VOLTAGE TEST DEVICE

• Testing of medium- and high-voltage cables
• DC voltage testing of up to 110 kV output voltage with positive or negative polarity
• AC voltage testing - up to 80 kV for switchgear, busbars and insulating elements
• Easy-to-maintain 2-piece design

 

BAUR PGK 50E / PGK 80E DC HIGH-VOLTAGE TEST DEVICE

• Continuous adjustable output voltage
• The voltage measurement is done directly at the high voltage output
• Timer of 1-30 min
• Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

 

BAUR SYSCOMPACT 2000 MOBILE CABLE FAULT LOCATION SYSTEM

• Fast and reliable
• Precise, dependable cable fault location
• High performance high voltage unit
• Integrated proven cable fault pre-location methods

 

BAUR SYSCOMPACT 2000 M PRO

• Fully integrated proven cable fault pre-location methods
• Surge mode for acoustic pin-pointing
• Easily transportable
• Ideal for locations that are difficult to access