Brand: TDK

Camera anecoica compacta Fully Compliant 26 MHz..1 GHz TDK CAC-S™ 2601

Cod: TDK CAC-S™ 2601


 

Brosura produs PDF, 0.16 Mb

Descriere

  • Dimensions:  7.0 m long x 3.0 m wide x 3.0 m high (23' L x 9'-10" W x 9'-10" H)
  • Absorbers:  X-131 Fully lined double layer ferrite
  • NSA test volume (@ 3 m):  1.0 m Ø, 1.0 m high
  • Field uniformity area (-0, +6 dB):  1.5 m x 1.5 m, 0.8 m from floor
  • Radiated emissions:  Compliance with EN 50147-2
  • Radiated immunity:  Compliance with IEC 1000-4-3
  • EMI frequency range:  30 MHz - 1 GHz
  • EMS frequency range:  26 MHz - 1 GHz

 

  • Radiated emissions: Pre-compliance with EN 50147-2, ANSI C63.4, CISPR 22
  • Radiated immunity: Full compliance with IEC 1000-4-3
  • Fully lined double layer ferrite tile and IP-045C absorber (TDK hybrid technology)
  • Space saving: 7.0 m long x 3.0 m wide x 3.0 m high (23' L x 9'-10" W x 9'-10" H)
  • Turnkey solution
 

Alte produse TDK

ANTENE DIPOL DE PRECIZIE PENTRU CALIBRAREA SURSELOR DE REFERINTA TDK SERIA DP

• Calibration
• Communications testing
• Antenna pattern measurements

 

LINIE TRANSMISIE GENERARE CAMP ELECTRIC SI MAGNETIC CONTROLAT DE MARE PUTERE 10 KHZ..100 MZ TDK EFG-02

• 10kHz - 100 MHz operating range
• High power field generator
• Up to 500 V/m RSM
• Low VSWR
• Adjustable height for optimizing performance

 

CAMERA ANECOICA COMPACTA COMPLET CONFORMA STANDARDE EMC 26 MHZ..18 GHZ TDK CAC-S™ 2618

• Dimensions: 7.5 m long x 3.0 m wide x 3.0 m high (24'-7" L x 9'-10" W x 9'-10" H)
• Absorbers: X-131 Fully lined double layer ferrite
• EMI frequency range: 30 MHz - 18 GHz
• EMS frequency range: 26 MHz - 18 GHz
• Radiated emissions: Pre-compliance with EN 50147-2, ANSI C63.4, CISPR 22
• Radiated immunity: Full compliance with IEC 1000-4-3

 

ANTENA COMPACTA LOG PERIODICA DE PRECIZIE 20 MZ..6 GHZ TDK HLP-2006C

• Frequency Range: 20 MHz to 6 GHz
• Gain: 6 dBi typical
• VSWR: 2:1 average
• Polarization: Linear
• Power Handling: 100 W
• Input Impedance: 50 ohms nominal
• Excellent low frequency response
• Unique internal balun provides balance even under adverse conditions

 

ANTENA DIPOL LOG-PERIODICA 800 MHZ..3 GHZ TDK LPDA-8003

• Fquency Range: 800 MHz to 3 GHz
• Gain: 8 dBi
• VSWR: 2:1 average
• Polarization: Linear
• Power Handling: 500W CW
• Feedpoint Impedance: 50 ohms nominal
• Compact broadband design

 

CAMERA ANECOICA COMPACTA FULLY COMPLIANT 26 MHZ..1 GHZ TDK CAC-S™ 2601

• Dimensions: 7.0 m long x 3.0 m wide x 3.0 m high
• Absorbers: X-131 Fully lined double layer ferrite
• Radiated emissions: Compliance with EN 50147-2
• Radiated immunity: Compliance with IEC 1000-4-3
• EMI frequency range: 30 MHz - 1 GHz
• EMS frequency range: 26 MHz - 1 GHz
• Radiated emissions: Pre-compliance with EN 50147-2, ANSI C63.4, CISPR 22
• Radiated immunity: Full compliance with IEC 1000-4-3

 

MASA CU GENERARE CAMP ELECTRIC PENTRU TESTARE EMC IN DOMENIUL AUTO TDK TP-02

• Immunity measurements to automotive test regulations
• Excellent linear response
• Designed to SAE specifications
• Capable of handling high power
• Integrated test table

 

ANTENA V-LOG PERIODICA BANDA LARGA 200 MHZ..1 GHZ TDK VLA-2001

• Frequency Range: 200 MHz to 1 GHz
• Gain: 8 dBi
• VSWR: 1.5:1 average
• Polarization: Linear
• Power Handling: 2.5 kw
• Impedance: 50 ohms nominal
• High power up to 2500 W

 

GENERATOR CAMP ELECTRIC SI MAGNETIC CONTROLAT DE MARE INTENSITATE 10 KHZ..100 MZ TDK EFG-03

• 10kHz - 100 MHz operating range
• High intensity field generator
• Generates greater than 500 V/m
• Low VSWR
• Adjustable height for optimizing performance

 

SISTEM INTEGRAT TESTARE RADIATIE/ CONDUCTIE EMS TDK EMS-TS

• Best-in-Class Test Instruments
• Fully Integrated Hardware and Software
• Remote Control of Switches and Positioning Devices
• Automated, Semi-automated, and Manual Testing
• Built-in System and Operator Safety
• Ergonomically Designed Test Consoles and Racks
• High Quality System Cabling and Connectors
• Quality Workmanship
• On-Site Training
• Comprehensive Warranty