Trusa incercare cu tensiune marita c.c. Seba HV Tester 25kV

Cod: Seba-KMT HV-Tester-25kV


 

Brosura produs PDF, 0.39 Mb

Descriere

HV Tester 25

The HV Tester 25 kV is a high-voltage generator with an infinitely variable negative DC output voltage of 0 - 25 kV. The condition of the test object with regard to electrical strength and insulation quality can be determined on the basis of the unit's readings for output voltage and current. 

Key benefits:

  • Portable HV Tester
  • DC and insulation testing of cables, joints, electrical fixtures, etc.
  • High flexibility with built-in battery

 

 

Description

The HV Tester 25 kV is a highvoltage generator with a variable negative DC output voltage of 0 … 25 kV.

 

The HV Tester 25 kV is used for:

Testing of newly installed cables and splices before they are taken into service

Testing of disconnected cables

Testing of electrical installations

Preventive checks after repairs and work on cables and other installations

 

Technical features

Easy operation

Built-in rechargeable battery for mains independent

operation

Low weight and compact design

Integrated discharge

Built-in timer

Stabilized adjustable output voltage

Voltage measurement direct at high-voltage output

HV-on with 0 kV interlock

Output short-circuit and open-circuit proof

Grounding safety circuit

 

 

Accesorii standard

Scope of Delivery

Tester, incl. rechargeable battery and leather case

Mains lead

Battery lead for external DC battery, approx. 3 m

Ground lead, approx. 3 m, for connection to station ground

Ground lead, approx. 3 m, for connection to protective ground

High voltage lead, approx. 3 m, with terminal

Operating manual

 

 

Optiuni recomandate

 

 

Alte produse SEBAKMT

TRUSA INCERCARI IZOLATIE CABLURI CU INALTA TENSIUNE SEBA HPG 50..110-H

• HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV
• HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV
• HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV
• Suitable for AC-testing and DC-testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

LOCATOR DE TRASEE CABLURI SI CONDUCTE SUBTERANE SEBA VLOC-9800

• Clearly laid out user interface
• Automatic or manual amplification options
• Depth and amperage at the press of a button
• Distance Sensitive Left/Right GuidanceTM
• Sheath fault location (optional)

 

SISTEM INCERCARE CU VLF CABLURI LUNGI SEBA CR-60-HP

• Sistem puternic de încercare 0,1 Hz VLF
• Putere mare de încercare fara reducerea frecventei
• Pentru cabluri de pâna la 20 km @ tensiune maxima
• Fara efecte de polarizare ca la CC
• Protocolare
• Detectarea strapungerii
• Masurarea curentului de fuga
• Încercare cu 3 Uo pentru cabluri de 36 kV adecvata pentru cabluri lungi si instalatii
• off-shore

 

SISTEM PENTRU LOCALIZAREA POZITIEI SI MASURAREA ADÂNCIMII CAMERELOR TV DE INSPECTIE PENTRU CANALIZARE SEBA EASYLOC CAM

• 3 active frequencies (512 Hz, 640 Hz und 33 kHz)
• depth measurement at the push of a button
• Maximum marker to mark the strongest signal
• optional: Carry Bag - for easy and safe transport of Easyloc Cam
• optional: Pipeline sonde - for location non-metallic pipes

 

CONVERTOR DEFECTE CU IMPEDANTA RIDICATA DE PE CABLURILE DE SEMNALIZARE, CONTROL SAU TELECOMUNICATII SEBA BT 500 IS-1

• Protectie la suprasarcina
• Sistem de descarcare automata
• Pentru conversia defectelor cu impedanta ridicata de pe cablurile de semnalizare, control sau telecomunicatii

 

TRUSA PENTRU INCERCAT IZOLATIE CABLURI CU TENSIUNE CONTINUA SI ALTERNATIVA SEBA HPG 50..80-D

• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV
• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV
• Suitable for AC testing and DC testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SISTEM LOCALIZARE DEFECTE CABLURI DE ENERGIE SI MANTA SEBA SURGEFLEX SFX 8-1000

• Încercare cu pâna la 8 kV
• Masurarea impulsului reflectat
• ARM® (Metoda reflexiei arcului)
• Metoda cuplarii în curent 2 / 4 / 8 kV
• Ardere (modificarea defectului)
• Localizarea traseului (optional)
• Masurarea distantei / câmpului acustic(2 / 4 / 4 kV cu 1000 J)
• Localizarea defectelor de manta

 

SISTEM LOCALIZARE ACUSTICA SI MAGNETICA EXACTA DEFECTE CABLURI SUBTERANE INGROPATE IN PAMANT SEBA DIGIPHONE+ NT SET

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

REFLECTOMETRU LOCALIZARE DEFECTE LINII COMUNICATII, COAXIALE, CABLURI ENERGIE ELECTRICA SEBA DIGIFLEX COM

• Pentru localizarea defectelor în linii de telecomunicatii de la 50 m la 30 km
• Rezolutie ridicata pe cabluri scurte sau lungi
• Afisaj dual pentru evaluarea clara a reflectogramei
• Rezolutie ridicata pâna la 2,5 cm în domeniul de 50 m
• Afisaj LCD de mari dimensiuni, cu iluminare

 

TRUSA ARDERE DE PUTERE CABLURI MEDIE TENSIUNE DEFECTOSCOPIE SEBA T22/13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage