Reflectometru localizare defecte cablu Megger TDR1000/3P

Cod: Megger TDR1000/3P


 

Brosura produs PDF, 0.14 Mb

Descriere

• Simple operation
• AUTO set up for instant use
• Ultra fast pulse for near end fault identification
• Trace HOLD feature to allow comparison between cables
• IP54 rating offers real life working
• No blocking filters require
• Supplied with fused test leads

 

A state-of-the-art single channel TDR capable of indentifying and locating faults on metalic cables. The TDR1000/3P is suitable for use on both dead or live cables

 

Accesorii standard

Time Domain Reflectometer TDR1000/3P

Included accessories

Hard carry case 5410-420

Fused test lead set 1002-015

User guide CD 2002-178

 

Optional accessories

Miniature clip test lead set 6231-652

 

Alte produse MEGGER

MULTI-AMP CIRCUIT BREAKER TESTER RETROFIT MEGGER DDA16, DDA30 AND DDA60

• Drop-in retrofit capability to the Multi-Amp Model CB-9116, Model DB-8130 and Model CB-8160 circuit breaker test sets
• Digital Signal Processing (DSP) technology
• Variable pulse time and firing-angle output-current control
• Complies with NEMA AB-4 Test Guidelines

 

TRUSA TESTARE TRANSFORMATOARE SI STATII TRANSFORMARE CAPACITATE FACTOR DE PUTERE SI DISIPATIE MEGGER TRAX

• Înlocuiește nevoia mai multor seturi de testare
• Sistem puternic, portabil și compact
• Reduce timpul de instruire a utilizatorilor și de testare
• Extinde durata de viață a transformatoarelor de putere
• Testarea stării izolației la 1 Hz
• Gestionează și analizează datele de testare

 

AC VOLTAGE DETECTORS MEGGER - VF1 AND VF2

• Socket outlets
• Fuses
• Switches
• Wires and cables
• Circuit breakers
• Luminares

 

EARTH LEAKAGE CLAMPMETER MEGGER - DCM300E

• 0.01 mA resolution
• EMC and IEC61010-2-032 compliance
• 30 mA, 300 mA, 30 A and 300 A range

 

TRUSA CURENT-TENSIUNE PENTRU VERIFICAREA RELEELOR DE PROTECTIE MEGGER FREJA 300

• can generate 4x150 V (82 VA) and 3x15 A (87 VA) or 1x45 A (250 VA).
• Manual and automatic control
• Easy to use
• Excellent software provides great visuals and simple setup
• Lightweight and portable
• Highly accurate
• User can calibrate unit

 

TESTER RAPORT TRANSFORMARE, DEPLASARE FAZA, REZISTENTA INFASURARE TRANSFORMATOARE MEGGER TTR100

• Tests turns ratio, phase displacement, excitation current, vector group, winding resistance and polarity
• Fully automatic; fast; easy-to-use; handheld; robust; lightweight
• Battery powered with power-saving and shutdown function
• Alphanumeric keyboard
• RS232 for data transfer and printing
• Stores 200 test results and 100 user-defined transformer test settings

 

DIGITAL CLAMP METER MEGGER - DCM310 AND DCM320

• Option of current only , DCM310 or multimeter, DCM320 models
• Measures up to 400 A a.c. with low current ranges for improved resolution
• 600 V a.c./d.c. DCM320
• 20 MO Resistance DCM320

 

TDR 2-CANALE LOCALIZARE DEFECTE CABLU MEGGER TDR2000/3 1003-036, TDR2000/3P 1003-037

• best resolution of 0.1m the TDR2000/2 has a 20km maximum range
• Comprehensive Dual Channel capability with dual aspect display.
• AUTO set up mode for instant use.
• Ultra fast pulse for near end fault identification.
• Xpert guidance to potential fault.
• IP54 rating offers real life working.
• Designed for use on all metallic paired cables.

 

MEGOHMETRU IZOLATIE 10000V 10KV MEGGER S1-1068/2

• Rezultate fiabile în substaţii zgomotoase
• Teste precise cu RE>Act™
• Control de la distanţă pentru testare mai sigură şi mai ușoară
• PI Predictor™ reduce timpul de testare la jumătate
• Suită completă de diagnosticare cu capacitate PDC

 

PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER ODEN AT

• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Modular design to permit optimal user configuration of output current vs. unit size
• Compact transport cart facilitates portability into switchgear rooms with limited space
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result