Brand: HART SCIENTIFIC

Termo-higrometru Logger Hart Scientific DewK 1620A

Cod: Hart Scientific DewK 1620A


 

Brosura produs PDF, 0.27 Mb

Descriere

  • Superior accuracy 
  • NEW! Network enabled 
  • Powerful logging and analysis tools 
  • Two interchangeable calibrated sensors 
  • Huge memory 
 

Optiuni recomandate

1621A-H 

The "DewK" Thermo-Hygrometer, High-Accuracy Value Kit (includes two high-accuracy sensors, wall mount bracket, RS-232 cable, 7.6 m [25 ft] sensor extension cable, sensor wall mount bracket, sensor case, and 9936A LogWare III single-PC license) 

1622A-H

 The "DewK" Thermo-Hygrometer, USB Wireless High-Accuracy Value Kit (includes 1621A-H Value Kit, 2633-RF, and 2633-USB)

1620A-H 

The "DewK" Thermo-Hygrometer, High-Accuracy (includes one high-accuracy sensor, wall mount bracket, and RS-232 cable) 

1621A-S 

The "DewK" Thermo-Hygrometer, Standard-Accuracy Value Kit (includes two standard-accuracy sensors, wall mount bracket, RS-232 cable, 7.6 m [25 ft] sensor extension cable, sensor wall mount bracket, sensor case, and 9936A LogWare III single-PC license) 

1622A-S

The "DewK" Thermo-Hygrometer, USB Wireless Standard-Accuracy Value Kit (includes 1621A-S Value Kit, 2633-RF, and 2633-USB)

1620A-S 

The "DewK" Thermo-Hygrometer, Standard-Accuracy (includes one standard-accuracy sensor, wall mount bracket, and RS-232 cable) 

Sensors 

2626-H 

Spare Sensor, high-accuracy 

2627-H 

Spare Sensor Kit (includes high-accuracy sensor, sensor case, sensor wall mount bracket, and 7.6 m [25 ft] extension cable) 

2626-S 

Spare Sensor, standard-accuracy 

2627-S 

Spare Sensor Kit, (includes standard-accuracy sensor, sensor case, sensor wall mount bracket, and 7.6 m [25 ft] extension cable) 

 

Alte produse FLUKE

BLOC USCAT PORTABIL CALIBRAT TEMPERATURI -10°C..122°C HART SCIENTIFIC 9102S

• -10°C to 122°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.05°C at 0°C

 

TERMOMETRU REFERINTA DE PRECIZIE 2 CANALE HART SCIENTIFIC 1524

• Two channels
• High accuracy
• PRTs: up to ± 0.011 °C
• Thermocouples: up to ± 0.24 °C
• Precision thermistors: ± 0.002 °C
• memory for logging 15,000 measurements

 

CUPTOR CALIBRARE TERMOCUPLE 150°C..1200°C HART SCIENTIFIC 9150

• 150 °C to 1200 °C temperature range
• Low-cost thermocouple furnace
• NIST-traceable calibration included
• RS-232 port standard

 

CALIBRATOR TEMPERATURA INFRAROSU 35°C..500°C HART SCIENTIFIC 4181

• Fast, portable and easy to use
• Correct target size for most thermometers
• Calibration solutions from 35 °C to 500 °C
• Radiometrically calibrated for traceable and consistent results

 

BAIE CALIBARE TERMOMETRE 50°C..700°C HART SCIENTIFIC 9173

• 50 °C to 700 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

CALIBRATOR TEMPERATURA, TERMOMETRE, TERMISTOARE 8 CANALE HART SCIENTIFIC 1560

• Reads SPRTs, RTDs, thermistors, and thermocouples
• Any configuration you like up to eight modules
• High-accuracy reference thermometer (to ±0.0013°C)
• Automates precision data acquisition

 

BLOC DUBLU CALIBRARE TEMPERATURI PENTRU INDUSTRIE -15°C..350°C HART SCIENTIFIC 9009

• Temperatures from -15 °C to 350 °C in one unit
• 50 °C to 350 °C Hot block, ± 0.6 °C Accuracy
• -15 °C to 110 °C Cold Block, ± 0.2 °C Accuracy
• ± 0.05 °C Stability

 

CALIBRATOR TEMPERATURA, TERMOMETRE, TERMISTOARE HART SCIENTIFIC 1594A / 1595A

• Calibrate SPRTs, PRTs, RTDs and thermistors (0 O to 500 kO)
• Accuracy as good as 0.06 ppm (0.000015 °C)
• "Ratio Self-Calibration" verifies and calibrates resistance ratio accuracy
• Automatic zero-power measurements calculate thermometer probe self-heating
• Temperature-controlled internal reference resistors

 

BAIE CALIBARE TERMOMETRE -45°C..140°C HART SCIENTIFIC 9170

• -45 °C to 140 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

BAIE CALIBARE TERMOMETRE 35°C..425°C HART SCIENTIFIC 9172

• 35 °C to 425 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world