Antena horn liniar polarizata octava 1..8 GHz ETS-Lindgren 3161

Cod: ETS-Lindgren 3161


 

Brosura produs PDF, 0.51 Mb

Descriere

  • Frequency Minimum     1 GHz
  • Frequency Maximum    8 GHz
  • Pattern Type     directional
  • Polarization       linear
  • Constant Antenna Factor Over Frequency
  • Complete with Feed, Waveguide, Mount
  • Increased Power Dissipation
  • Optimal Beam width
  • Low VSWR

 

 

Model

Frequency

E-Plane

H-Plane

Maximum Continuous Power

Antenna Factor

Gain

Typical Field Strength

3161-01

1.00 - 2.00 GHz

26°

26°

550 W

16.9 dB (1/m)

16.3 dBi

700 V/m

3161-02

2.00 - 4.00 GHz

22°

22°

250 W

22.3 dB (1/m)

17.5 dBi

500 V/m

3161-03

4.00 - 8.00 GHz

22°

22°

250 W

28.3 dB (1/m)

17.5 dBi

500 V/m

Physical Specifications Comparison

Model

Connectors

Wave Guide No.

Weight

Width

Depth

3161-01

Type N female

WR - 650

8.00 kg   ( 17.64 lb )

53.14 cm   (20.92 in)

88.05 cm   (34.67 in)

3161-02

Type N female

WR - 320

5.00 kg   ( 11.02 lb )

34.61 cm   (13.63 in)

59.34 cm   (23.36 in)

3161-03

Type N female

WR - 159

2.00 kg   ( 4.41 lb )

17.47 cm   (6.88 in)

31.88 cm   (12.55 in)

 

Alte produse ETS-LINDGREN

FILTRE PUTERE APLICATII TEMPEST/RFI/ EMI DE MARE PERFORMANTA CURENTI 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

FILTRE RFI/ EMI CONTROL LINIE PENTRU SISTEME ALARMA, DETECTIE SI MONITORIZARE ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options

 

FILTRE PROTECTIE RETEA MONOFAZATA APLICATII RFI/EMI PUTERE & CURENT INALT 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

ANTENA BICONICA TRANSMISIE-RECEPIE 20..200 MHZ ETS-LINDGREN 3104C

• Frequency Minimum 20 MHz
• Frequency Maximum 200 MHz
• Connectors Type N (f)
• FS-600 High Performance Hybrid Ferrite Tile Polyurethane Dielectric 200 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Pattern Type omnidirectional
• Peak Power 100 W
• Polarization linear

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

FILTRE DE PUTERE PROTECTIE RADIATII RFI/ EMI CURENTI 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 20..220 MHZ ETS-LINDGREN 3151

• 20 MHz to 220 MHz frequency range
• High power feed handles up to 5 kW RF input power
• Space saving design features tophat-loaded, low-frequency elements
• Mounted on wheeled base for easy mobility

 

TESTER EMF CAMP ELECTRIC & MAGNETIC RF CONFORM CU STANDARDE INDUSTRIALE 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

ANTENA ACTIVA BUCLA DE RECEPTIE 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2