YOKOGAWA Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A)

Code: YOKOGAWA CL150


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

1.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

.5?% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz)

Method of detection

Mean Value

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W) x 247(H) x 49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

More products YOKOGAWA

YOKOGAWA AQ6373B VISIBLE WAVELENGTH OPTICAL SPECTRUM ANALYZER 350 - 1200 NM

• Max safe input power: +20 dBm
• Level sensitivity: -80 dBm
• Dynamic range: ?60dB
• Single-mode, Multimode, and Large-core fibers
• Built-in optical alignment source

 

YOKOGAWA 2553A PRECISION DC CALIBRATOR

• Digital Display of Output
• High Basic Accuracy
• High Stability and Low Noise
• High Resolution

 

YOKOGAWA AQ2180 SERIES PORTABLE OPTICAL POWER METER (W/ DATA STORAGE/TRANSFER)

• Two versions of Power Meters to suit test application
• Versatile data storage and transfer
• Auto switching of measurement wavelength
• Power source

 

YOKOGAWA GS610 SOURCE MEASURE UNIT

• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
• Basic accuracy: ±0.02% (DC voltage generation)
• Sweep output at up to 100-µ intervals
• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65535 points of source measure data in the internal memory

 

YOKOGAWA GS820 MULTI CHANNEL SOURCE MEASURE UNIT

• DC voltage/current reference, pulse voltage/current source
• V-I curve trace, semiconductor parametric test
• Programmable arbitrary waveform generation
• Electric load, resistance measurement
• Production test

 

YOKOGAWA - MINI CLAMP-ON TESTER CL120 (200A)

• Exclusive model for AC current measurement with current ranges up to 200A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display

 

YOKOGAWA - PROCESS CALIBRATOR CA300 SERIES CA310 CA320 CA330

• Basic Accuracy: 0.015% (Source&Meas. accuracy of Voltage mA)
• Simultaneously supplies 24V loop power and measure output signal with high accuracy
• Sub display displays span% of the source value
• HART/BRAIN comm. resistance (250O) embedded

 

YOKOGAWA AQ6360 TELECOM PRODUCTION OPTICAL SPECTRUM ANALYZER 1200 - 1650 NM

• Wavelength range: 1200 to 1650 nm
• Wavelength resolution: 0.1 to 2 nm
• High wavelength accuracy: ±0.02 nm
• High dynamic range: 55 dB
• Wide measurement range: +20 to -80 dBm

 

YOKOGAWA - LEAKAGE CURRENT TESTER 322610 (ANALOG)

• ± 2.5% full scale accuracy
• 100µA full scale value
• Shockproof indicator using taut band movement
• Built-in overload protection circuit
• Handy and easy to carry

 

YOKOGAWA DIGITAL INSULATION TESTER MY40

• 3 1/2-digit LCD;
• For each rating, you can save as many as 20 measurements at desired memory address numbers.
• Four AA (R6P) batteries the tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.