YOKOGAWA Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A)

Code: YOKOGAWA CL150


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

1.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

.5?% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz)

Method of detection

Mean Value

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W) x 247(H) x 49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

More products YOKOGAWA

YOKOGAWA - DIGITAL MANOMETER MT220

• Measurement with DCV and DCA
• 24 V DC output
• Percent reading
• Error reading
• Measurement data memory

 

YOKOGAWA - MINI-MANOMETER MT10

• High reliability (with silicon resonant sensor)
• Compact
• Accuracy: ± (0.04% of rdg + 0.03% of F.S.) (130 kPa model)

 

YOKOGAWA LOW PRESSURE CALIBRATOR CA700

• IP54 dustproof and water proof case for harsh environments
• 4-20mA step function for signal generation
• 20mA Simulator to carry out loop test.
• Two-wire Transmitter Loop Check

 

YOKOGAWA - PX8000 PRECISION POWER SCOPE

• Provides simultaneous voltage and current multiplication to give real-time power sampling.
• Trend measurements between waveforms can be calculated by mathematical functions (up to four million points).
• Supports the capture of power parameters over specific periods of time through the definition of start and stop "cursors".
• An always-active History function automatically records up to 1,000 historical waveforms.

 

YOKOGAWA AQ1100 OPTICAL LOSS TEST SET

• 5.7 inch color LCD for easy viewing
• Multi-Language support
• Multi-core fiber measurement with a pair set
• USB port for data storage

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA AQ1300 SERIES 1G/10G ETHERNET MULTI FIELD TESTER

• Optical and electrical measurement ports for 10M to 1G (AQ1301) and 10M to 10G (AQ1300) are available
• Built-in Optical power meter (factory-installed option for the AQ1300)
• Equipped with a variety of test functions to evaluate Ethernet performance, such as a throughput test, latency measurement, bit error rate test, and PING test.

 

YOKOGAWA AQ2170 SERIES PORTABLE OPTICAL POWER METER (SIMPLE & COMPACT)

• Two versions of Power Meters to suit test application
• Compact and lightweight
• Rubber protector to prevent damage when dropped

 

YOKOGAWA AQ6370D TELECOM OPTICAL SPECTRUM ANALYZER 600 - 1700 NM

• High wavelength accuracy: ±0.01nm
• High wavelength resolution: 0.02nm
• Wide dynamic range: 78dB typ.
• Wide level range: +20 to -90dBm

 

YOKOGAWA CLAMP-ON TESTER CL130 (ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• Mean value display
• Data hold function