Active Differential Probe for Oscilloscopes 100MHz Testec TT-SI

Code: Testec TT-SI


 

Description

TT-SI 9101  1:10 / 1:100, 100MHz

Bandwidth: 100MHz

Attenuation Ratio1: x10 / x100

Accuracy: ± 2%

Rise Time: 3,5ns

Input Impedance: 4Ω, 7pF

 

Only connect to a grounded oscilloscope!

 

Input Voltage

Differential Mode

            x10: +-70V (DC + peak AC) or 70Vrms

            x100: +-700V (DC +peak AC) or 700Vrms

 

Common Mode

            x10: +-700V (DC + peak AC) or 700Vrms

            x100: +-700V (DC +peak AC) or 700Vrms

 

Absolute max. Voltage

            x10: +-1400V (DC + peak AC) or 1000Vrms CAT III

            x100: +-1400V (DC +peak AC) or 1000Vrms CAT III

 

Output Voltage

            Swing: ± 7V (into 50kW load)

            Offset (typical): <± 5mV

            Noise (typical): 0,9mVrms

            Source Impedance: 50W

            CMRR (typical): -85dB@50Hz, -50dB@1MHz

 

 

 

TT-SI 9110  1:100 / 1:1000, 100MHz

Bandwidth: 100MHz

Attenuation Ratio: x100/x1000

Accuracy: +/-2%

Input Impedance: 4Ω, 7pF

 

Only connect to a grounded oscilloscope!

 

Input Voltage

Differential Mode

            x100: +-140V (DC + peak AC) or 140Vrms

            x1000: +-1400V (DC +peak AC) or 1000Vrms

 

Common Mode

            x100: +-1400V (DC + peak AC) or 1000Vrms

            x1000: +-1400V (DC +peak AC) or 1000Vrms

 

Absolute max. Voltage

            x100: +-1400V (DC + peak AC) or 1000Vrms CAT III

            x1000: +-1400V (DC +peak AC) or 1000Vrms CAT III

 

Output Voltage

            Swing: +-1,4V (into 50kΩ load)

            Offset (typical): <+-5mV

            Noise (typical): 0,6mVrms

            Source Impedance (typical): 50Ω

            CMRR (typical): -80dB@60Hz, -50dB@1MHz

 

 

 

Power requirements: 4x AA Cells or Mains Adaptor 6VDC/200mA or regulated 9VDC/120mA

Dimensions (LxWxH): 207 mm x 83 mm x 38 mm

Length: BNC Cable 90 cm - Input Leads 30 cm

Weight: 500 g

Accessories: we recomend mains adaptor TT-SI NT

 

 

More products TESTEC

PASSIVE OSCILLOSCOPE PROBE 1X ATTENUATION TESTEC TT-MF100

• TT-MF 112 1:1 - 1,2m, 30MHz
• TT-MF 116 1:1 - 1,6m, 27MHz
• TT-MF 120 1:1 - 2,0m, 25MHz


PASSIVE OSCILLOSCOPE PROBE 10X ATTENUATION TESTEC TT-MF200

• TT-MF 212 10:1 - 1,2m, 250MHz
• TT-MF 216 10:1 - 1,6m, 220MHz
• TT-MF 220 10:1 - 2,0m, 190MHz


VOLTAGE OSCILLOSCOPE PROBE 1X ATTENUATION TESTEC TT-HF100

• TT-HF 112 1:1 - 1,2m, 40MHz
• TT-HF 120 1:1 - 2,0m, 30MHz
• TT-HF 212 10:1 - 1,2m, 300MHz


VOLTAGE OSCILLOSCOPE PROBE 10X ATTENUATION HIGH FREQUENCY TESTEC TT-HF400

• TT-HF 412 10:1 - 1,2m, 350MHz
• TT-HF 420 10:1 - 2,0m, 270MHz


VOLTAGE OSCILLOSCOPE PROBE 10X ATTENUATION TESTEC TT-HF200

• TT-HF 212 10:1 - 1,2m, 300MHz
• TT-HF 220 10:1 - 2,0m, 230MHz


CURRENT PROBE FOR OSCILLOSCOPE DC..5MHZ TTI I-PROBER 520

• I-prober 520 - PCB track Touch & Measure
• Current measurement from insulated probing of conductor
• Suitable for observation and measurement of current in PCB tracks, component leads and ground planes
• Wide dynamic range of 10mA to 20A peak to peak
• Wide bandwidth of DC to 5MHz
• Low noise figure equivalent to <6mA rms at full B/W

 


ACTIVE DIFFERENTIAL PROBE FOR OSCILLOSCOPES 25MHZ TESTEC TT-SI

• TT-SI 9001 1:10 / 1:100, 25MHz
• TT-SI 9002 1:20 / 1:200, 25MHz


HIGH VOLTAGE OSCILLOSCOPE PROBE 100X ATTENUATION TESTEC TT-HV

• TT-HV 150 100:1, 300MHz
• TT-HV 151 100:1, 200MHz
• TT-HV 250 100:1, 300MHz
• TT-HV 251 100:1, 200MHz


KELVIN TEST LEAD TESTEC TT-20000

• TT-22000 Connector: 5 Pin DIN-Plug
• TT-22020 Connector: 5x 4mm Banana-Plug