Seba KMT TDM 200 Flow measurement equipment in pipes
OBSOLET PRODUCT ( * OUT OF USE )

Code: Seba-KMT TDM-200


 

Datasheet PDF, 1.96 Mb
     

Description

TDM 200

Portable flow measurement

Using a TDM 200 flow meter enables a quick and easy to install flow measurement.

An internal data logger stores all measurements and provides a wireless data transmission to a computer to analyse the data. If no data recording is necessary or the actual flow shall be watched by the operator, the actual flow can be seen online. 

Key features:

  • Ideal for temporary flow measurements
  • Wireless communication
  • Optional alarm transmission
  • Internal rechargeable battery pack
  • Integrated pressure sensor
  • Convertible for all connections

 

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA SWG 500 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG500

• Voltage Ranges : 0..2.5kV / 5kV / 10kV ; 0..4kV / 8kV / 16kV
• Energy : 195J ; 500Joules
• MAx Current Imax : 185mA ; 300mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT HPG 50..110-H DC & AC HIGH VOLTAGE CABLE TESTING SETS

• HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV
• HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV
• HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV
• Suitable for AC-testing and DC-testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA KMT VFL SINUS 45KV SINE WAVE CABLE TEST SYSTEMS

• VLF sine wave 45 kV with integrated tanDelta
• compact, robust, and portable
• high-performance test and diagnostic system for medium voltage cables
• Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
• Automatically adjusts the test frequency to the cable length
• Eliminates hazards to the user and guarantees limited damage to the cable
• Easy field operation with no need for external computer

 

SEBA TELEFLEX VX CABLE REFLECTOMETER FOR FAULT LOCATION SYSTEMS

• Range : 20 m … 1280 km
• Bright and large display
• Easiest operation via self guiding and explaining menus
• ARM Slide Technology
• Automatic storage of all results
• Supports all existing prelocation technologies
• Automatic detection and display of cable end and fault position

 

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter

 

SEBA KMT PD LOC PARTIAL DISCHARGE PINPOINTING SYSTEM FOR RPECISE LOCATION OF PD FAULTS IN MEDIUM VOLTAGE CABLES

• Precise PD pinpointing in mixed cable networks
• Location of faults in joints of single core cables
• Easy handling in the ?eld

 

SEBAKMT CORRELUX C-3 HYBRID LEAK NOISE CORRELATOR, ONLINE AND OFFLINE

• Precise leak detection
• State-of-the-art sensor technology
• Online and offline correlation
• Simple operation
• Robust design

 

SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000

• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter