Power Quality Analyzer for Single and Three Phase Photovoltaic Systems HT Italia Solar300N
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia Solar300N


 

Datasheet PDF, 1.63 Mb
 

Description

  • DC/AC TRMS (single-phase and three-phase) voltage measurement
  • DC/AC TRMS (single-phase and three-phase) current measurement
  • DC/AC (single-phase and three-phase) power measurement
  • AC (single-phase and three-phase) energy measurement
  • Measurement of power factor (cosphi) single-phase and three-phase
  • Measurement of solar irradiation [W/m2]
  • Measurement of environmental and module temperature by means of probe PT1000
  • Recording of voltage and current harmonics up to the 49th
  • Recording of voltage anomalies (dips, peaks)
  • Flicker analysis in compliance with standard EN50160
  • Recording of starting currents with a resolution of 10ms
  • Recording of voltage fast transients (spikes) with a resolution of 5us
  • Complete analysis of mains quality in compliance with standard EN50160
  • Numerical and graphical display of each quantity
  • Recalling results on the display
  • TFT colour display with touch screen
  • Power supply with rechargeable Li-ION battery
  • Memory extension by means of compact flash (CF card)
  • Data transfer to external USB memory (memory stick)
  • USB port for PC connection
  • Help on line at display
 

Standard accessories

  • SOLAR-02: Remote unit to record irradiation and temperature
  • KIT800: Kit including 5 banana cables (black/blue/red/green/brown) + 5 alligator clips (black/blue/red/green/brown)
  • HT4005K: Transducer for AC currents 0÷200 A AC, 3pcs 
  • HT4004N: Transducer for DC currents 0÷10 - 0÷100 A
  • HT304: reference cell for irradiation measurement
  • PT300N: Double temperature probe (PT1000 + environmental)
  • A0055: Power supply 230V / 50-60Hz EU plug
  • YABAT0003HT1: Li-Ion 3,7V rechargeable battery
  • PT400: Touch screen pen
  • TOPVIEW2007: Software on CD-ROM and USB connection cable C2007
  • VA400: Hard Carrying case
  • User manual on CD-ROM
  • Quick guide
  • Calibration certificate ISO9000
 

Recommended options

  • MPP300: Multi-string three-phase adaptor
  • HT4004P: Unbatterried transducer for DC current 0-10, 0-100A, max diameter 30mm (**)
  • HT96U: Transducer for AC currents (including leakage current) 0÷1 - 0÷100 - 0÷1000A
  • HT97U: Transducer for AC currents 0÷10 - 0÷100 - 0÷1000 A AC
  • HT98U: Transducer for AC/DC currents 0÷1000 A AC/DC
  • HP30C2: Transducer for AC currents 0÷200 - 0÷2000 A AC
  • HTFLEX33D: Flexible transducer for 3000A AC current, diameter 174mm (*)
  • HTFLEX35: Flexible transducer for 3000A AC currents diameter 274mm (*)
  • HT903: Transducer 3x1-5A/1V for connection to CTs with accessories
  • SP-0400: Free hands kit
  • 606-IECN: Connector with magnetic clip
  • (*) only for using the instrument as power quality analyser
  • (**) to be used with MPP300 only
 

More products HT ITALIA

INSULATION CONTINUITY MEGOHMMETER AND DIGITAL MULTIMETER HT ITALIA M72

• Insulation Resistance with 250, 500VDC
• Measurement range up to 1GOhm
• Automatic discharging object after test
• Continuity test of protective conductors with 200mA
• DC Voltage
• AC TRMS Voltage

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation

 

HANDHELD DIGITAL EARTH RESISTANCE METER HT ITALIA GEO416

• 3-wire Earth Resistance
• 2-wire Earth Resistance
• 4-wire Earth Resistivity
• High measurement range (50kOhm)
• Noise voltage measure
• Optical /USB PC interface

 

I-V600 ADVANCED MULTIFUNCTION INSTRUMENT FOR I-V CURVE MEASUREMENTS UP TO 1500V AND 40A

• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891
• SOLAR03 remote unit with Bluetooth connection
• Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2
• Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

THT80 COMPACT INFRARED THERMOGRAPHY CAMERA 120X90PXL

• IR Resolution 120 x 90 pxl
• Temperature range -20° ÷ 550°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 50° x 37°

 

POWER ANALYZER CURRENT CLAMP METER HT ITALIA HT9022

• DC, AC + DC TRMS current up to 1000A
• DC, AC + DC TRMS voltage up to 1000V
• Resistance and continuity test
• Active, Reactive, Apparent power on Single/Three phase systems
• Active, Reactive energy on Single/Three phase systems
• Power Factor on Single/Three phase systems
• Harmonic voltage/current up to 25th with THD% calculation
• PC connection via Bluetooth

 

SAFETY TESTER FOR PHOTOVOLTAIC SYSTEMS HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell