HIGHTEST CIBRE-L3 Circuit Breaker Analyzer

Code: CIBRE-L3 CIBRE-L3B BLUE


 

Datasheet PDF, 1.21 Mb
     

Description

CIBRE-L3 3-Contact Circuit Breaker Timer with built-in Printer
CIBRE-L3 BLUE 3-Contact Circuit Breaker Timer with built-in Bluetooth & Printer
CIBRE-L3B 3-Contact Circuit Breaker Timer with built-in Battery & Printer
CIBRE-L3B BLUE 3-Contact Circuit Breaker Timer with built-in Battery, Bluetooth & Printer


CIBRE-L3 Series, 3-Contact Circuit Breaker Timers are designed using advanced engineering technology to test contact timings of circuit-breakers.

CIBRE-L3 Series have fast, easy and accurate measurement features by its user-friendly software.

CIBRE-L3 Series are battery-powered devices (optional feature), which allow users to perform tests even without power supply during field tests.

Why do we need to test circuit breakers?

It is very important to test circuit breakers regularly. Contact Timing Tests are performed to determine the optimal performance of the breakers.

The testing can determine improper breaker operations in case of system fault and to improve system reliability.

Contact Timing Tests

Contact timing tests are performed to compare the breakers’ main & resistor contact performance against the manufactures specifications.

The breakers OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN and OPEN-CLOSE-OPEN operations are timed in milliseconds (ms) and cycles and then compared with the manufacturers’ specification to determine the performance of the circuit breaker.

CIBRE-L3 Series feature with a 4.3-inch large colour touch display, which is visible under both bright sunlight as well as dim light conditions.

Operators can easily print the measurement results with the 2.25-inch built-in printer of CIBRE-L3 Series.

The results can also save to a USB flash drive or to the device’s internal memory.

Multi-language capability and user-friendly operation menu make it easy to control CIBRE-L3 Series.

CIBRE-L3 Series devices are light-weight, compact and rugged with the protection of IP67 (case closed) which makes it perfect for the field test.

Features

  • Contact Timing (O, C, O-C, C-O & O-C-O)
  • 3 Dry Contact Inputs
  • Timing Accuracy: 0.05% rdg ± 0.1 ms
  • Timing Windows: 1s, 10s & 20s
  • Contact Detection Range: Closed ≤20 Ω &
  • Open ≥5000 Ω
  • Optional Battery
  • Optional Bluetooth Communication
  • 2.25” Built-in Printer
  • 4.3” TFT Touch Colour Display
  • Lightweight and Portable
  • Protection Class IP67 (case closed)

Technical Specifications

Measurement ParametersContact Timing (O, C, O-C, C-O & O-C-O)
Dry Contact Inputs3 dry input channels (each detects main)
Timing Windows1s, 10s, 20s
Timing Resolution1 s duration10 s duration20 s duration
± 50 µs± 500 µs± 1 ms
Timing Accuracy0.05% rdg ± 0.1 ms
Dry contact channel protectionFuses and Diodes protection, All contacts grounded until test
Contact detection rangeClosed≤20 Ω
Open≥5000 Ω
Resistor detection range20Ω – 5000Ω
Trigger input voltage24 – 300 V DC or ACpeak
Dry contact input protectionDiode Protection/ ESD
Breaker OperationsOPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, OPEN-CLOSE-OPEN
Breaker Initiate Capacity20 A, 300 V DC or ACpeak
Initiate current reading range0 – 20A DC, 5 kHz
Input Power100-240 V,  47/63 Hz
BatteryYes, 14.4 V 3.45 Ah ( Optional; Models: CIBRE-L3B & CIBRE-L3B BLUE)
Display4.3-inch Colour Touch Display
MemoryUp to 200 records
CommunicationUSB 2.0/1.1 Standard-A, USB 2.0/1.1 Standard-B
Bluetooth (Factory install option; Models: CIBRE-L3 BLUE & CIBRE-L3B BLUE)

Printer2.25-inch Built-in Printer
Dimensions12.5″ x 10.1″ x 6.0″  (318 mm x 257 mm x 152 mm )
Weight3 kg (models with battery)
Working Temperature-10 °C to +60 °C
Humidity95% RH non-condensing
Protection ClassIP67 (case closed)



Video presentation HIGHTEST CIBRE-L3



 

Standard accessories

Scope of Supply
CIBRE-L3 device, 6m Contact Cable, 10m Contact Extension Cable, 1m Initiate Cable, 5m Initiate 
Extension Cable, 1m External Trigger Cable, 5m External Trigger Extension Cable, Power Cord, 
Ground Cable, USB Cable, Printer Paper (2x), USB Flash Drive, DMP Software, Instruction Manual 
(soft copy), Soft Carry Bag

 

More products HIGHTEST

HIGHTEST CIBRE-L3 CIRCUIT BREAKER ANALYZER

• Contact Timing (O, C, O-C, C-O & O-C-O)
• 3 Dry Contact Inputs
• Timing Accuracy: 0.05% rdg ± 0.1 ms
• Timing Windows: 1s, 10s & 20s
• 2.25” Built-in Printer
• 4.3” TFT Touch Colour Display

 

HIGHTEST CIBRE-60 6-CONTACT TIMING CIRCUIT BREAKER ANALYSERS

• Contact Timing (O, C, O-C, C-O and O-C-O)
• Motion Tests (Transducer Speed, Stroke, Bounce)
• 6 Dry Contact Inputs
• Timing Accuracy: 0.05% rdg ± 0.1 ms
• Timing Windows: 1s, 10s & 20s
• 7TFT Touch Colour Display

 

HIGHTEST TRAN-203 TRANSFORMER ANALYZER FOR TURN RATION AND WINDING RESISTANCE TESTING

• Turns ratio measurement (Single-phase & Three-phase)
• Winding resistance measurement (Single-phase & Three-phase)
• Heat run test/Temperature rise test
• Magnetic Balance Test

 

HIGHTEST TRIORES-20 TRANSFORMER WINDING RESISTANCE TESTER

• Fully Automatic Three-phase and single-phase resistance measurement with three-phase cable configuration
• Measurement range, 0.1 uOhm to 100,000 Ohm
• 0.001 A to 20 A DC adjustable current output
• High accuracy (0.1%)
• Test Voltage 50 V
• Demagnetisation feature

 

HIGHTEST CBSM

• Contact timing channels 6 contact timing channels; Accuracy: 0.01 ms
• CT timing channel 1 CT timing channel, 500 mA, Accuracy: +-0.5 ms
• Digital transducer channels 3 digital transducer channels; Accuracy: 0.02
• V1 voltage channel 20 Vrms
• V2 voltage channel 30 Vdc
• Internal trigger channel 2 A
• External trigger channel 24 Vdc

 

HIGHTEST TRCAL-10K TURN RATIO METER CALIBRATOR

• Ratio Range 1 to 10,000 (1:1, 2:1, 5:1, 10:1, 50:1, 100:1, 200:1, 500:1, 1,000:1, 2,000:1, 5,000:1, 10,000:1)
• Exciting Voltage Range 1 V -250 V
• Exciting Windings H1-H2 Windings

 

HIGHTEST HARE CONTACT RESITANCE TESTER CIRCUIT BREAKER, SHUNT, DISCONNECTOR

• Portable Contact Resistance Tester
• 0.4A to 100A Adjustable test current (HARE-100)
• 0.4A to 200A Adjustable test current (HARE-200)
• 0.4A to 300A Adjustable test current (HARE-300)
• Up to 5 Ohm resistance measurement
• 0.1 uOhm resolution
• Automatic discharge

 

HIGHTEST CIBRE-30 CIRCUIT BREAKER TESTER ANALYZER

• Contact Timing (O, C, O-C, C-O and O-C-O)
• Motion Tests (Transducer Speed, Stroke, Bounce)
• 3 Dry Contact Inputs
• Timing Accuracy: 0.05% rdg ± 0.1 ms
• Timing Windows: 1s, 10s & 20s
• 2.28” Built-in Printer
• 7” TFT Touch Colour Display

 

HIGHTEST SUWI-120 MULTIFUNCTION SUBSTATION TESTER

• Multifunctional test device
• Relay Timing Tests
• Turns Ratio Tests
• Contact Resistance Tests
• 3ph Circuit Breaker Timing Tests

 

HIGHTEST WINRES-20 WINDING RESISTANCE OHMMETER TESTER

• 2-channel resistance measurement
• Measurements from 0.1 uOhm to 100,000 Ohm
• 0.001 A to 20 A DC adjustable current output
• High accuracy (0.1%)
• Test Voltage 50 V
• Demagnetisation feature