The GDM-300/400 Series Hand Held DMM are a compact, high precision, battery operated multimeter series designed to meet most of the daily needs for design engineers as well as service engineers. The GDM-300/400 series design is driven by mobile-oriented features, such as automatic power down to preserve battery life, a large backlight display for crisp viewing, a rotary selector switch and clear-cut push buttons to ease operation. The basic functions match the depth of bench-top multimeters: fuse-protected current input, true RMS for accurate AC measurements, Auto ranging, Duty cycle, and Relative mode. These compact, reliable, and economical devices are ideal for any engineer.

 

Features:

  • 4 1/2 Digits 19999 counts (GDM-452), 3 1/2 Digits 1999 counts (GDM-357/350B)
  • Manual Ranging, Continuity Beeper/Diode Test, Data Hold
  • hFE Test (GDM-350B)
  • Temperature Measurement (GDM-357/350B)
  • Capacitance (GDM-452/357)
  • Frequency Measurement (GDM-452)
  • < >
  • 4000 Counts Auto/Manual Ranging (GDM-397/398)
  • 6000 Counts Auto/Manual Ranging (GDM-360)
  • Capacitance, Frequency Measurement
  • Continuity Beeper/Diode Test
  • High Energy Fuse for 10A Range
  • Data Hold/Relative Mode
  • True RMS (GDM-461/360)
  • RS232C (GDM-461/397/360)
 

More products GW INSTEK

DIGITAL OSCILLOSCOPES 2/4CH. 70/100/200/300MHZ INSTEK GDS-2000A

• GDS-2072A 70MHz ,2-channel ,Visual Persistence DSO
• GDS-2074A 70MHz ,4-channel ,Visual Persistence DSO
• GDS-2102A 100MHz ,2-channel ,Visual Persistence DSO
• GDS-2104A 100MHz ,4-channel ,Visual Persistence DSO
• GDS-2202A 200MHz ,2-channel ,Visual Persistence DSO
• GDS-2204A 200MHz ,4-channel ,Visual Persistence DSO
• GDS-2302A 300MHz ,2-channel ,Visual Persistence DSO
• GDS-2304A 300MHz ,4-channel ,Visual Persistence DSO

 

GOODWILL INSTEK GLC-9000

• Touch Panel with Color LCD Display
• 9 Different Measurement Network to Simulate the Resistance of Human Body
• 8 Different Types of Leakage current for Medical & General Electrical Equipment
• Various Leakage Current Measuring Mode:DC/AC/AC+DC/AC Peak

 

GOODWILL INSTEK GFC-8010H

• 10Hz ~ 120MHz Range
• 8 Digits Display (0.3"LED)
• 15mV rms High Sensitivity
• 5PPM High Stability Time Base
• Frequency and Period Measurement

 

SPECTRUM ANALYZER 9KHZ..3GHZ GW INSTEK GSP-930

• Frequency Range: 9kHz ~ 3GHz
• High Frequency Stability: 25ppb (0.025ppm)
• RBW: 10Hz ~ 10kHz in 1-3 steps, 10kHz ~ 1MHz in 10% adjustable steps
• Phase Noise: -88dBc/Hz @1GHz, 10kHz Offset
• Built-in Measurement Functions: Channel Power, N-dB bandwidth, OCBW, ACPR, SEM, TOI, CNR, CTB, CSO
• Built-in Spectrogram and Topographic Display Modes

 

GOODWILL INSTEK GFG-3015

• Built-in 6 Digits Counter up to 150MHz/High Resolution
• Output Waveform : Sine,Square,Triangle,Ramp,Pulse,Sweep,Gate or Burst
• INT/EXT AM/FM Modulation
• GCV Output for Synchronization

 

GOODWILL INSTEK PSB-1000 SERIES

• Power on Configuration
• Internal Sense Control( Disable/ front panel/ rear panel)
• Voltage trigger function
• Output delay function

 

GOODWILL INSTEK GPC-SERIES

• Auto Series and Parallel Operation
• Constant Voltage and Constant Current Operation
• Low Ripple and Noise
• Internal Select for Continuous or Dynamic Load

 

GOODWILL INSTEK GFG-8200A SERIES

• Frequency Range: 0.3Hz ~ 3MHz (GFG-8215A/8216A/8217A/8219A)
• Frequency Range: 0.5Hz ~ 5MHz (GFG-8250A/8255A)
• Waveforms: Sine, Triangle, Square,Ramp, TTL and CMOS Output
• External Voltage Controlled Frequency (VCF) Function

 

GOODWILL INSTEK PSW-SERIES

• CV/CC Priority; Particularly Suitable for the Battery and LED Industry
• Adjustable Slew Rate
• Series Operation: Up to 2 units (30V, 80V, 160V models only)
• Parallel Operation: Up to 3 units

 

GOODWILL INSTEK SPS-SERIES

• 0.01 % High Regulation
• Constant Voltage and Constant Current Operation
• High Efficiency
• High Power Density