Multifunctional Tester for Temperature, Humidity, Velocity, CO, CO2 Fluke 075 AirMeter

Code: Fluke 975 AirMeter


 

Datasheet PDF, 0.42 Mb

Description

  • Temperature -20 °C to 50 °C (-5 °F to 122 °F)
  • Velocity 0.25 m/sec to 15 m/sec
  • Relative Humidity 10 % to 90 % RH, non-condensing
  • CO2 0 to 5000 ppm
  • CO 0 to 500 ppm

 

  • Respond to comfort-related calls from occupants.
  • Verify the operation of building HVAC control systems.
  • Determine whether adequate ventilation exists.
  • Monitor air flow and velocity.
  • Test for dangerous carbon monoxide leaks.
  • Perform duct traversals.
  • Optimize HVAC systems to manage energy costs

 

  • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
  • One-touch air flow and velocity with available probe*
  • Wet bulb and dew point temperature
  • % of outside air calculation
  • CO2 and CO field calibration feature
  • Self-test function at startup
  • Auto-backlight
  • Automatically compensates for barometric pressure changes
  • Min/Max/Average on all measured and calculated readings
  • Multi-language user interface
  • Metric or standard units
  • Audible and visual threshold alarms
  • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
  • Keypad lock for security
  • Included FlukeView Forms® software
 

Standard accessories

Fluke 975V      AirMeter™ with Velocity        

Fluke 975         AirMeter™

 

 

  • A4 alkaline batteries (3)
  • Users Manual
  • Calibration Cap
  • FlukeView Forms Software
  • Power Adapter
  • International Power Plugs
  • Air Velocity Probe (Fluke 975V only)
 

More products FLUKE

FLUKE 115 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• AC/DC Current
• Capacitance and Frequency

 

CURRENT CLAMP METER TRUE-RMS AC/DC 200A FLUKE 365

• 200 A AC and DC current measurement with detachable jaw
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• 6000 O resistance measurement

 

LASER DISTANCE METER 60M FLUKE 416D

• Ability to measure up to 60 m (200 ft) with increased accuracy of up to 1.5 mm (0.06 in)
• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.

 

FLUKE 190-502 190-502/S HANDHELD DIGITAL OSCILLOSCOPE 2X500 MHZ

• 2-channels isolated 500MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

LASER DISTANCE METER 30M FLUKE 411D

• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.
• Designed for indoor and outdoor use.

 

WIRELESS CURRENT CLAMP FLUKE CNX A3000

• True-RMS AC current measurements to 400 A
• 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT III 600 V; IP42


INTERNAL BATTERY RESISTANCE ANALYZER FLUKE BT520

• Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
• Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
• Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
• Wireless communication
• USB Port

 

FLUKE 700G/TRACK DATALOGGING SOFTWARE FOR 700G PRESSURE GAUGES

• Precision pressure measurement from -20 mbar to 690 bar
• Absolute pressure measurement ranges 15, 30, 100, 300 psia
• Accuracy to 0.05 % of full scale
• Reference class gauge accuracies to 0.04 % of reading
• Easy to use, rugged construction for reliable performance

 

FLUKE 712B RTD TEMPERATURE CALIBRATOR

• measure and simulate (13) different RTD types and resistance
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

AIR QUALITY PARTICLE COUNTER FLUKE 985

• Six channels and particle size range of 0.3 - 10.0 µm
• Ultra-lightweight and ergonomic design
• Large 3.5 QVGC Color display
• 10,000 record storage
• USB/Ethernet charge cradle