Multifunctional Tester for Temperature, Humidity, Velocity, CO, CO2 Fluke 075 AirMeter

Code: Fluke 975 AirMeter


 

Datasheet PDF, 0.42 Mb

Description

  • Temperature -20 °C to 50 °C (-5 °F to 122 °F)
  • Velocity 0.25 m/sec to 15 m/sec
  • Relative Humidity 10 % to 90 % RH, non-condensing
  • CO2 0 to 5000 ppm
  • CO 0 to 500 ppm

 

  • Respond to comfort-related calls from occupants.
  • Verify the operation of building HVAC control systems.
  • Determine whether adequate ventilation exists.
  • Monitor air flow and velocity.
  • Test for dangerous carbon monoxide leaks.
  • Perform duct traversals.
  • Optimize HVAC systems to manage energy costs

 

  • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
  • One-touch air flow and velocity with available probe*
  • Wet bulb and dew point temperature
  • % of outside air calculation
  • CO2 and CO field calibration feature
  • Self-test function at startup
  • Auto-backlight
  • Automatically compensates for barometric pressure changes
  • Min/Max/Average on all measured and calculated readings
  • Multi-language user interface
  • Metric or standard units
  • Audible and visual threshold alarms
  • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
  • Keypad lock for security
  • Included FlukeView Forms® software
 

Standard accessories

Fluke 975V      AirMeter™ with Velocity        

Fluke 975         AirMeter™

 

 

  • A4 alkaline batteries (3)
  • Users Manual
  • Calibration Cap
  • FlukeView Forms Software
  • Power Adapter
  • International Power Plugs
  • Air Velocity Probe (Fluke 975V only)
 

More products FLUKE

INFRARED THERMOMETER FLUKE FOOD PRO

• Infrared temperature range from -35 to 275 ºC
• HACCP check lights for instant recognition of safe/unsafe temperatures
• LED target illumination highlights the entire measurement spot for accurate targeting
• Hand washable (IP54 sealed)
• Probe temperature range -40 to 200 ºC(Fluke Food Pro Plus)

 

FLUKE TIX520 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

FLUKE RDL2 HVAC UV FLASHLIGHT FOR REFRIGERANT LEAKAGE DETECTION

• Six UV LEDs (395 nm wavelength) detect leak detection dyes
• Laser pointer clearly locates center of the UV field for accuracy
• Three LED flashlight with 100,000 hour LED life
• Operating temperature 0 ° C to 50 ° C
• Four operating modes: flashlight, UV light, laser light, UV/laser light combination


FLUKE NORMA 5000 PRECISION POWER ANALYZER

• 3, 4 or 6 power phases
• Bandwidth from dc to 3 MHz / 10 MHz
• FFT analysis, vector diagram, and Digital Oscilloscope
• Voltage, current and power harmonics measured up to the 40th harmonic

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

LASER DISTANCE METER 60M FLUKE 416D

• Ability to measure up to 60 m (200 ft) with increased accuracy of up to 1.5 mm (0.06 in)
• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.

 

FLUKE 77IV HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count resolution
• 0.3% basic accuracy
• Large display
• Backlight for work in dim areas

 

INFRARED NON-CONTACT THERMOMETER FLUKE 61

• Bright laser beam provides easy targeting
• Display clearly supplies data at a glance
• Shock-absorbing holster increases ruggedness
• 0.2 °C (0. 5 °F) resolution up to 275 °C (525 °F)
• Backlight illuminates the screen in the dark
• Automatic sleep mode after 7 seconds extends battery life
• Alkaline batteries provide 4000 typical measurements

 

WIRELESS CURRENT CLAMP FLUKE CNX A3000

• True-RMS AC current measurements to 400 A
• 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT III 600 V; IP42


FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

• 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
• 0.1 % basic accuracy (0.05 % for PM 6304C)