Fluke Memobox 1745 Three Phase Power Quality Logger

Code: Fluke Memobox 1745


 

Datasheet PDF, 0.51 Mb

Description

  • monitor for logging power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
  • measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
  • Plug and play: Setup in minutes with automatic current probe detection and powering
  • Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces next to live power
  • Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables
  • Monitors power for the long-term: Data can be downloaded during recording without interruption
  • 0.1% voltage accuracy IEC61000-4-30 Class-A compliant 
  • Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview
  • Rugged and reliable: Designed for everyday field use with no moving parts and durable insulated case with two year warranty
  • real-time LCD
  • five hour UPS
  • IP50 advanced protection
 

Standard accessories

Fluke 1745 include:
  • CD-ROM with PQ Log software
  • RS232 interface cable and RS232-USB adapter
  • Test leads for voltages and power supply
  • 4 black dolphin clips
  • Color localization kit
  • Carrying bag
  • Test certificate with measurement values
  • Printed English manual
  • Multi-language manual CD
  • 4 flexible current clamps FS17xx 15/150/1500/3000 A with 2 m cable
 

Recommended options

VL1735/45

Voltage Lead Set

I1A/10A Clamp PQ3

Clamp PQ3 3-Phase 1A/10A

I1A/10A Clamp PQ4

I1A/10A Clamp PQ4

I20A/200A Clamp PQ3

I20A/200A PQ3 3-Phase Clamp

I20A/200A Clamp PQ4

I20A/200A PQ4 Clamp

I5A/50A Clamp PQ3

I5A/50A Clamp PQ3 3-Phase 5A/50A

I5A/50A Clamp PQ4

Clamp PQ4 5A/50A

 

More products FLUKE

INDUSTRIAL MAINTENANCE SYSTEM FLUKE CNX 3000 GM

• • True-RMS AC and DC voltage measurements to 1000V
• • True-RMS AC and DC current with 0.01 mA resolution
• • True-RMS AC voltage measurements to 1000V
• • True-RMS AC current measurements to 2500 A


FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

• 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
• 0.1 % basic accuracy (0.05 % for PM 6304C)
• Easy to use, at-a-glance display

 

FLUKE 1625-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

FLUKE II500 ACOUSTIC CAMERA FOR DETECTION AND INSPECTION OF COMPRESSED GAS LEAKS

• Easy, fast, and safe visual detection of compressed gas leaks.
• The 7" LCD touchscreen displays a SoundMap™ over visual images, making it easier to locate leaks quickly.
• Intuitive interface requires no training for maintenance teams.

 

FLUKE TIX500 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

MULTIFUNCTIONAL TESTER FOR TEMPERATURE, HUMIDITY, VELOCITY, CO, CO2 FLUKE 075 AIRMETER

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

FLUKE TI400 INFRARED CAMERA 320X240 RESOLUTION

• 320x240 Detector resolution
• Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
• Range: -20 °C si +1200 °C
• Precision : ± 2 °C sau 2%
• Sensibility : = 0,05 °C

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 324

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement

 

PROCESS MULTIMETER FLUKE 789

• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool
• HART mode setting with loop power

 

FLUKE TI300 INFRARED CAMERA 240X180 RESOLUTION

• 240x180 Detector resolution
• Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
• Range: -20 °C si +650 °C
• Precision : ± 2 °C sau 2%
• Sensibility : = 0,05 °C