Documenting Process Calibrator Fluke 743B

Code: Fluke 743B


 

Datasheet PDF, 0.13 Mb

Description

  • 0 to 300 V DC/AC Voltage measure
  • 0 to 15 V DC Voltage source / simulate
  • 0 to 110 mA DC Current measure
  • 0 to 22 mA DC Current  source / simulate
  • 0 to 11 kO Resistance measure / source / simulate
  • 1 to 50 kHz Frequency measure / source / simulate
  • PC interface and data logging

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Measure and source simultaneously with one compact, rugged, reliable tool
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white display. Read both sourced and measured parameters
  • Multi lingual interface
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1msec.
 

Standard accessories

  • BC7217 battery charger
  • BP7217 battery pack
  • Instruction manual
  • NIST-traceable calibration report and data
  • One set of TP220 test probes
  • Two sets of AC220 test clips
  • Two sets of TL224 industrial test leads
  •  

    More products FLUKE

    WIRELESS TEMPERATURE K-TYPE ACQUISITION MODULE FLUKE CNX T3000

    • Temperature measurements from -200 °C to 1372 °C
    • ± 0.5% accuracy
    • Memory recording up to 65,000 readings
    • Backlit LCD display
    • IP30


    FLUKE 116 HANDHELD DIGITAL MULTIMETER HVAC 3.5 DIGIT

    • 3.5 digit
    • 6000 count
    • 0.5% accuracy
    • Built-in thermometer for HVAC applications
    • Microamps to test flame sensors

     

    FLUKE 1587 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

    • Insulation test: 0.01 MO to 2 GO
    • Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

     

    DIGITAL PYROMETER FLUKE 63

    • Single point offset laser sighting
    • Best accuracy in its class: + 1% of reading
    • Holds temperature readings for 7 seconds
    • Dual displays shows current and MAX measurements simultaneously
    • Backlit display for poorly lit areas
    • Wide temperature range from -30º to 500ºC (-20º to 932ºF)

     

    LASER DISTANCE METER 50M FLUKE 414D

    • Instantly measures up to 50m (165 feet) with one button
    • Laser accuracy of +/- 2mm (0.08 in)
    • Easy, automatic math for area and volume, add and subtract with ease

     

    FLUKE NORMA 5000 PRECISION POWER ANALYZER

    • 3, 4 or 6 power phases
    • Bandwidth from dc to 3 MHz / 10 MHz
    • FFT analysis, vector diagram, and Digital Oscilloscope
    • Voltage, current and power harmonics measured up to the 40th harmonic

     

    INTERNAL BATTERY RESISTANCE ANALYZER FLUKE BT510

    • Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
    • Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
    • Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
    • Wireless communication
    • USB Port

     

    FLUKE 6303A LCR METER 1 KHZ

    • 1 kHz test frequency
    • 0.25% accuracy
    • test signal level: 2V via 400O source

     

    LASER DISTANCE METER 80M FLUKE 419D

    • Instantly measures up to 80m (260 ft) with accuracy of +/- 1mm
    • 3-line display plus storage for 20 complete displays
    • Tripod mountable

     

    POWER QUALITY CLAMP METER FLUKE 345

    • 2000A AC/DC current
    • 600 V CAT IV power analyzer
    • Data logging
    • Troubleshoot harmonics
    • Inrush current