Fluke 6306 Automatic RCL Meter 50 Hz..1 MHz

Code: Fluke 6306


 

Datasheet PDF, 0.08 Mb

Description

  • 50, 60, 100, 120 Hz  200 Hz to 100 kHz (100 Hz steps)
  • 100 kHz to 1 MHz (1 kHz steps) test frequencies
  • 0.1 % basic accuracy
  • Easy to use, at-a-glance display
  • RS-232 and IEEE-488 interfaces
  • AC test levels from 50 mVrms to 2 Vrms
  • Internal or external bias
  • DC test measurement (optional)
  • 9 front panel set-ups
  • Actual component test voltage/current readback
  • Automatic zero trimming
  • Front-panel test posts for immediate 4-wire measurements
  • Contact check and deviation mode
 

More products FLUKE

FLUKE TIS40 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

PRESSURE CALIBRATOR FLUKE 718

• Pressure Source and Milliamp Measurement
• Best in class mA accuracy of 0.015 %
• 1, 30, 100 & 300 PSI ranges available

 

INFRARED NON-CONTACT THERMOMETER FLUKE 572

• Backlit display for poorly lit areas
• Last ten temperature readings displayed on bar graph for easy reference
• Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
• Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
• MIN/MAX measurements calculations instantly computed
• Audible and visible HI temperature alarm for instant recognition

 

FLUKE 1630 EARTH GROUND CLAMP METER

• resistance range from 0.025 O to 1500 O
• large jaw opening of 35 mm
• ground leakage current, from 0.2 mA to 1000 mA
• ac current measurement range from 0.2 A to 30 A

 

FLUKE 1652C MULTIFUNCTION INSTALLATION TESTER 250V-1000V

• Test voltage: 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results

 

FLUKE 1625-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

VOLTAGE CONTINUITY TESTER FLUKE T90/ T110/ T130/ T150

• Voltage AC/DC 12V - 690V
• Continuity 0 - 400 k?
• Frequency 0 / 40 - 400 Hz
• Phase rotation
• Resistance measurement

 

VOLTAGE CONTINUITY TESTER FLUKE T140

• Resistance measurement
• Backlight
• LED Bargraph
• Display: 3½ digit LCD
• Voltage test
• Optical and acoustical continuity test

 

FLUKE RDL2 HVAC UV FLASHLIGHT FOR REFRIGERANT LEAKAGE DETECTION

• Six UV LEDs (395 nm wavelength) detect leak detection dyes
• Laser pointer clearly locates center of the UV field for accuracy
• Three LED flashlight with 100,000 hour LED life
• Operating temperature 0 ° C to 50 ° C
• Four operating modes: flashlight, UV light, laser light, UV/laser light combination


FLUKE 1577 MEGOHMMETER INSULATION MULTIMETER 500/ 1000V

• Insulation test: 0.1 MO to 600 MO
• Insulation test voltages: 500 V, 1000 V