Fluke 1750 Three Phase Power Logger

Code: Fluke 1750 1750-Basic


 

Datasheet PDF, 0.6 Mb

Description

  • Power quality that meets the standard: comply with IEC61000-4-30 standards for voltage, current, power, harmonics, flicker etc.
  • 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events
  • 5 MHz Transient Voltage
  • Quick and reliable configuration: PDA wireless "front panel interface provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations
  • Threshold-free set up: Apply thresholds after data is collected with Fluke Power Analyze Software - no need to worry about missed information due to incorrect setups
  • Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time
  • Intuitive PC software: automated EN50160 reporting and compliance
  • Reporting has never been easier: Auto Report creates either standard reports or customized reports with the minimum effort or hassle. 
  • Plug and play: Set up in minutes with self-identifying current probes and single-lead voltage connections
  • No need to reconnect wires: Swap channels internally with the wireless PDA or PC when connections are not correct
  • Measure every parameter: Voltage and current on three phases, neutral, and ground
  • Quickly retrieve data: included SD memory card
  • 100BaseT high-speed Ethernet connection
 

Standard accessories

Fluke 1750/B include:
  • 1750 acquisition unit
  • PDA wireless "front panel interface" and charger power plug adapters
  • 5 Test leads and clips
  • SD memory card
  • Fluke Power View and Fluke Power Analyze software
  • Power cord with international plug set
  • Ethernet cable
  • Color localization set
  • Printed Getting Started manual
  • Product CD with software and user manual PDF
  • CS 1750/1760 Rugged transit softcase
Fluke 1750 also include:
  • 4 x 400A current probes (3140)
 

Recommended options

Current clamps

3005-PR

Model 3005R CT

3014-PR

40 A Clamp-on CT

3110-PR

100 A Flexi-CT (60 cm)

3210-PR

1000 A Flexi-CT (60 cm)

3310-PR

5000 A Flexi-CT (60 cm)

3312-PR

5000 A Flexi-CT (120 cm)

 

More products FLUKE

FLUKE 1625-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

FLUKE 437 II POWER QUALITY AND ENERGY ANALYZER

• 400 Hz measurement
• Power inverter efficiency: Simultaneously measure AC output power and DC input power
• PowerWave data capture: Capture fast RMS data, show half-cycle and waveforms
• Energy loss calculator
• Troubleshoot real-time
• Highest safety rating in the industry
• Measure all three phases and neutral

 

FLUKE TIS40 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

PHASE ROTATION INDICATOR FLUKE 9040

• 3 phase indication
• Indication of phase rotation
• Clear LCD display
• No battery required

 

FLUKE 27 II HANDHELD MULTIMETER RUGGED IP67 INDUSTRIAL 4.5 DIGIT

• 4.5 digit
• 20,000 count resolution for precise measurements
• 0.05% basic accuracy
• New - IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments

 

FLUKE VT02 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 20° X 20°
• 4 GB Micro SD card

 

VOLTAGE CONTINUITY TESTER FLUKE T90/ T110/ T130/ T150

• Voltage AC/DC 12V - 690V
• Continuity 0 - 400 k?
• Frequency 0 / 40 - 400 Hz
• Phase rotation
• Resistance measurement

 

FLUKE TIS10 INFRARED CAMERA 80X60

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 700PTPK PNEUMATIC TEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi (69 bar) or less, to make a complete pressure testing kit
• Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump
• Connect the 700G Series gauge directly to the included PTP-1 hand pump
• Includes hoses and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

INDUSTRIAL MEASUREMENT SYSTEM FLUKE CNX 3000 HVAC

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• Temperature measurements from -200 °C to 1372 °C
• True-RMA AC current measurements to 400 A