Brand: FLUKE BIOMEDICAL

Electrical Safety Analyzer Fluke Biomedical DALE 601E

Code: Fluke Biomedical DALE 601E


 

Description

  • Small, lightweight, self-contained portable instrument
  • Master range meter delivers accurate measurment for each test
  • Accurate test measurements with 4-wire Kelvin bridge
  • Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
  • Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
  • All Leakage Current measurements are displayed directly in µAmps
  • Broad range of external measurements
  • Five (5) Universal EKG Lead Connectors
  • The DALE601E is designed for 230 V operation

 

 

Specifications

Mains Voltage

 

 230 Volts, 50/60 Hz

Instrument Current

Range:

 0 - 10.00 Amps

Resolution:

 10 mA

Accuracy:

 5 % R

Ground (Earth) Resistance

Range: 0 - 1.99

 Accuracy: 1% R ± 1 LSD

              2 - 19.99

 Accuracy: 2 % R ± 1 LSD

Resolution:

 10 mOhms

Leakage Current

Range:

 0 - 1, 999 µA

Accuracy:

 DC & 25 Hz - 1kHz: ±1% of reading, ± 3LSD

 

 1.0KHz - 100 KHz: ±2.5% of reading, ± 3LSD

 

 100 KHz - 1 MHz: ±5% of reading, ± 3LSD

Type Measurement:

 True RMS

Test Load:

 AAMI or IEC601-1 (selectable)

Current Consumption

Range:

 0-14.99A(Dale 601-1515)

 

 0-19.99A(Dale 601-1520/2020)

 

 0-9.99A(Dale 601E)

Current Capacity

Dale 601-1515

 15Amps

Dale 601E

 10Amps

Dale 601-1520/2020

 20Amps, 20% duty cycle (2 minutes on, 8 minutes off)

Controls

 

 1. Function Switch - 9 position rotary

 

 2. Lead Switch - 6 position rotary

 

 3. Neutral Switch - 2 position rocker (Open/Closed)

 

 4. Polarity Switch - 3 position rocker (Normal/Off/Reversed)

 

 5. Leakage Switch - 2 position rocker (Chassis/Earth)

DUT Power

 

 10 Amps @ 230 V

Physical Size

 

 4.0 x 7.8 x 1.6 inches (102 x 196 x 41 mm)

 

More products FLUKE BIOMEDICAL

LUNG PRECISION TEST SINULATOR FLUKE BIOMEDICAL ACCU LUNG

• Small, lightweight and portable
• User-selectable compliance and resistance settings
• Calibrated accuracy for both resistance and compliance
• Complies with IEC standard for breathing- circuit connection
• Certified test lung for test system traceability to standards

 

INCUBATOR ANALYZER FLUKE BIOMEDICAL INCU

• Portability (sitting in place of infant within incubator)
• Single-instrument measurement and documentation for key infant-incubator parameters
• Measurement for most parameters according to IEC and AAMI standards
• Time-saving in testing critical infant incubators
• Windows® software for evaluation and documentation
• Numerical and graphical reports

 

AUTOMATED ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL MEDTESTER 5000C

• Easy verification of biomedical equipment to manufacturer’s specifications
• Ten preprogrammed and five user-programmable electrical-safety-testing sequences
• Convenient transfer of equipment inventory and testing procedures from CMMS
• Automatic storage of detailed test results for printing or transfer to CMMS
• Compliant with ANSI/AAMI (1993) and NFPA-99 (2005) standards
• 20-A device testing with GFCI protection

 

MULTIFUNCTION PARAMETER TESTER OF DIFFERENTIAL PRESSURE, VACUUM, TEMPERATURE FLUKE BIOMEDICAL DPM4

• Palm size
• High accuracy
• Differential pressure, vacuum, and temperature measurements
• Multiple user-selectable units of measurement
• Simultaneous display of multiple parameter measurements
• Leak detection/leak-rate calculation
• RS232 for computer control

 

LIM/ GFI ISOLATION CURRENTS TESTER FLUKE BIOMEDICAL DALE2000

• Unique digital circuitry retains measurement
• Direct reading of Line Voltage, LIM and GFI current
• 9 volt battery operation
• Universal voltages from 85 to 245 VAC, 50/60 Hz
• Small, lightweight, very portable


DEFIBRILLATOR PULSE EXTERNAL PACER ANALYZER FLUKE BIOMEDICAL 6000D/ 7000DP

• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
• AED technology compatibility
• First-class measurement accuracy ± 1 % of reading + 0.1 J
• Intuitive user interface and backlight, easy-to-read display
• Portable, rugged, easy to carry

 

ELECTROSURGERY ANALYZER FLUKE BIOMEDICAL RS303 RS

• New Signal Averaging Mode (SAMTM)
• New RS232 port
• Battery powered for completely isolated measurement
• Digital display
• HF-leakage-current measurement
• 4-digit numeric LCD with backlight and power-save mode

 

DIGITAL ELECTRICAL SAFETY TESTER FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA620

• Compliance with multiple standards
• Three test loads
• Expanded leakage ranges through 10,000 µA
• AC only, DC only and True RMS leakage readings
• 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
• 20 A equipment current

 

NEUTRON SURVEY METER MONITOR FLUKE BIOMEDICAL190N

• Auto-scaling measurement of rate and dose (integrate mode includes dose and time accumulation)
• True Rem readings recorded across a wider (lower and higher) rate range
• Ergonomic, portable design: adjustable shoulder strap and rugged handle with padded grip
• Flexible detector assembly, 190 can be removed for remote readings
• Available in SI units