Brand: FLUKE BIOMEDICAL

Pressurized Ion Chamber Survey Meter for Gamma, X-Ray Radiation Fluke Biomedical 451P

Code: Fluke Biomedical 451P


 

Datasheet PDF, 0.37 Mb
   

Description

The auto-ranging 451P features a pressurized ion chamber, providing enhanced sensitivity (µR resolution) and improved energy response to measure radiation rate and dose from x-ray and gamma sources. Originally designed to measure leakage and scatter around diagnostic x-ray and radiation therapy suites, the 451P’s site surveying capabilities make it well-suited for a wide range of end users, including: x-ray manufacturers, government agencies, state inspectors, biomedical technicians, and maintenance technicians for airport baggage scanners.

The ion chamber detector allows for a fast response time to radiation from leakage, scatter beams and pinholes. Additionally, the low noise chamber bias supply provides for fast background settling time.

 

The digital display features an analog bar graph, 2.5 digit digital readout, low battery and freeze ("peak hold") mode indicators, and an automatic backlight function. User controls consist of an ON/OFF button and a MODE button. The case is constructed of lightweight, high strength materials and is sealed against moisture. The RS-232 interface can be connected directly to a computer for use with the Excel add-in for Windows (451EXL), enhancing the functionality of the instrument. This software allows for data retrieval, user parameter selection and provides a virtual instrument display with audible (requires sound card) and visual alarm indication.

 

  • High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
  • Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
  • Programmable flashing LCD display and audible alarm
  • Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case
  • RS-232 communications interface with optional Windowsbased Excel add-in for data logging
  • Available with dose equivalent energy response (SI units)
  •  CE Tested. Meets applicable standards
 

Standard accessories

Models:
  • 451P-RYR Pressurized µR Ion Chamber Survey Meter with standard chamber 

    451P-DE-SI-RYR Pressurized µR Ion Chamber Survey Meter with dose equivalent chamber 

 

More products FLUKE

HANDHELD ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL 175

• Ultra-portable (fitting in a briefcase)
• IEC601-1 and AAMI test loads
• Self-switching 120/240 V operation
• Point-to-point testing

 

ELECTROSURGERY ANALYZER FLUKE BIOMEDICAL QA-ES

• Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor
• High-frequency leakage measurements with accuracy of ± 2 % of reading
• 128 internal user-selectable test loads from 10 O to 5200 O
• Ansur QA-ES software plug-in for automated test protocols
• RS-232 and Centronic-printer interface

 

INCUBATOR ANALYZER FLUKE BIOMEDICAL INCU

• Portability (sitting in place of infant within incubator)
• Single-instrument measurement and documentation for key infant-incubator parameters
• Measurement for most parameters according to IEC and AAMI standards
• Time-saving in testing critical infant incubators
• Windows® software for evaluation and documentation
• Numerical and graphical reports

 

MULTIFUNCTION TESTER OF GAS FLOW, VOLUME, VACUUM, PRESSURE, OXIGEN CONCENTRATION FLUKE BIOMEDICAL VT MOBILE

• Bidirectional flow (high- and low-flow ranges), volume, vacuum, pressure, and oxygen-concentration measurements
• 16 ventilator parameter measurements
• Trending and statistical analysis of all measured values
• Onboard graphical display
• Portable and compact
• RS232 for computer control
• Memory for storing results
• VT for Windows PC software

 

OXIGEN O2 CONCENTRATION ANALYZER FLUKE BIOMEDICAL MAXO2 PLUS AE

• One-touch calibration, with reminder
• Long battery life (approx. 5,000 hrs)
• Impact resistant and drip proof
• External MAX-250E Oxygen Sensor

 

AUTOMATED ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL MEDTESTER 5000C

• Easy verification of biomedical equipment to manufacturer’s specifications
• Ten preprogrammed and five user-programmable electrical-safety-testing sequences
• Convenient transfer of equipment inventory and testing procedures from CMMS
• Automatic storage of detailed test results for printing or transfer to CMMS
• Compliant with ANSI/AAMI (1993) and NFPA-99 (2005) standards
• 20-A device testing with GFCI protection

 

DIGITAL RADIATION MONITOR FLUKE BIOMEDICAL PRIMALERT 05-443/ 05/444

• LED digital display
• Low and High alarm indicators
• Programmable alarm indicator
• Optional remote
• Detector Fail indicator
• Battery backup
• Data output/RS-232

 

DIGITAL ELECTRICAL SAFETY TESTER FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA612

• Portable, ergonomic, lightweight, and easy to use
• Large, easy-to-read display with adjustable contrast
• Human-factors-designed user interface
• Tilt stand design for stand-up testing in field environments
• Five applied parts jacks and easy ECG snap connection

 

ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA620

• Compliance with multiple standards
• Three test loads
• Expanded leakage ranges through 10,000 µA
• AC only, DC only and True RMS leakage readings
• 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
• 20 A equipment current