Brand: FLUKE BIOMEDICAL

Electrosurgery Analyzer Fluke Biomedical QA-ES

Code: Fluke Biomedical QA-ES


 

Datasheet PDF, 0.17 Mb
 

Description

  • Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor
  • Oscilloscope output
  • High-frequency leakage measurements with accuracy of ± 2 % of reading
  • 128 internal user-selectable test loads from 10 O to 5200 O
  • Foot-switch output for triggering the ESU under test
  • Ansur QA-ES software plug-in for automated test protocols
  • Large display
  • RS-232 and Centronic-printer interface
 

Standard accessories

  • Operator’s Manual (PDF or CD) (CD-ROM)
  • Operator’s Manual (hard copy) (MANUAL)
  • ESU-Dispersive safety lead (ESU DISPERSIVE LD)
  • ESU-CQM safety lead (ESU CQM LEAD)
  • ESU-Jumper safety lead (ESU JUMPER LEAD)
  • Test lead with stackable plugs (4MM TL BLACK)
  • Test lead set with retractable sheaths (ESU CABLE)
  • Sure-grip large alligator clip set (AC285)
  • County-specific power cord
  • 115 V USA (14301)
  • 230 V 10 A Schuko (14300)
 

More products FLUKE BIOMEDICAL

ELECTROSURGERY ANALYZER FLUKE BIOMEDICAL RS303 RS

• New Signal Averaging Mode (SAMTM)
• New RS232 port
• Battery powered for completely isolated measurement
• Digital display
• HF-leakage-current measurement
• 4-digit numeric LCD with backlight and power-save mode

 

NEUTRON SURVEY METER MONITOR FLUKE BIOMEDICAL190N

• Auto-scaling measurement of rate and dose (integrate mode includes dose and time accumulation)
• True Rem readings recorded across a wider (lower and higher) rate range
• Ergonomic, portable design: adjustable shoulder strap and rugged handle with padded grip
• Flexible detector assembly, 190 can be removed for remote readings
• Available in SI units


ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA620

• Compliance with multiple standards
• Three test loads
• Expanded leakage ranges through 10,000 µA
• AC only, DC only and True RMS leakage readings
• 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
• 20 A equipment current

 

ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL 601 PRO

• EN60601-1, EN601010-1, and AAMI test loads (user selectable)
• Multiple enclosure-leakage points
• Multiple patient-applied-part types
• Power ON/OFF delay
• DC only for patient- and auxiliary-leakage tests
• User-programmable test sequences

 

ULTRASOUND ELECTRICAL SAFETY TRANSDUCER LEAKAGE CURRENT TESTER FLUKE BIOMEDICAL ULT800

• Handheld
• Stand-alone operation
• Direct measurement of leakage current
• Battery-operated
• Independent of 120 V or 240 V systems
• Built-in self-test circuit
• Auto shut-off to conserve battery

 

PNEUMATIC TRANSDUCER PRESSURE GENERATING/ MEASURING FLUKE BIOMEDICAL DPM1B

• Battery operated
• Generates and measures positive or negative pressures
• Operates with gas and liquid
• Troubleshooting with 1 % accuracy

 

PRESSURIZED ION CHAMBER SURVEY METER FOR GAMMA, X-RAY RADIATION FLUKE BIOMEDICAL 451P

• High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
• Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm
• Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case

 

UNIVERSAL DIGITAL RADIATION MONITORING RATEMEMTER FLUKE BIOMEDICAL 942A/ 946A/ 952A

• User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
• Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
• Small front panel size allows dedicated display for each channel while minimizing panel space
• Ability to use existing cables when replacing most analog readouts

 

ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA612

• Portable, ergonomic, lightweight, and easy to use
• Large, easy-to-read display with adjustable contrast
• Human-factors-designed user interface
• Tilt stand design for stand-up testing in field environments
• Five applied parts jacks and easy ECG snap connection

 

DIGITAL ELECTRICAL SAFETY TESTER FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993