Brand: FLUKE BIOMEDICAL

Defibrillator Pulse External Pacer Analyzer Fluke Biomedical 6000D/ 7000DP

Code: Fluke Biomedical 6000D/ 7000DP


 

Datasheet PDF, 0.5 Mb
         

Description

  • Impulse 7010 Defibrillator Selectable Load Accessory provides multiple loads of 25 ?, 50 ?, 75 ?, 100 ?, 125 ?, 150 ?, 175 ?, and 200 ? to comply with IEC 60601-2-4 standard (optional)
  • Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
  • AED technology compatibility
  • First-class measurement accuracy ± 1 % of reading + 0.1 J
  • Intuitive user interface and backlight, easy-to-read display
  • Portable, rugged, easy to carry
  • Long-lasting, rechargeable battery
  • Pacer brand selections
  • Pacer input protected against defibrillator output (7000DP only)
  • 10 independent ECG outputs that provide 12 lead combinations for standardized clinical signals
  • Flexible heart-rate settings (1 BPM step) facilitate rate meter accuracy and alarm testing
  • DSP-based measurements enable future firmware and waveforms upgrade
  • Unique integrated posts for secure connections
  • Two-year extended warranty (no-cost extended warranty available after first-year calibration at any Fluke Biomedical authorized service center)
  • Optional Ansur test automation software to standardize testing procedures, capture waveforms and test results, and print and document test results
  • Designed, tested, and built to incomparable Fluke quality standards
 

Standard accessories

 

Model Name

Description

Impulse 6000D

Impulse 6000D Defibrillator Analyzer 120 V - US

All models include:

  • USB Computer Communication Cable (cable assembly)
  • User Manual CD (CD-ROM)
  • Getting Started Guide (Manual)
  • Battery Eliminator (country specific)
  • Defib Paddle Contact Plates (FBC-IMP7000-8010)
  • Carrying Case (soft case)

Impulse 6000D-01

Impulse 6000D Defibrillator Analyzer Schuko

Impulse 6000D-02

Impulse 6000D Defibrillator Analyzer UK

Impulse 6000D-03

Impulse 6000D Defibrillator Analyzer Japan

Impulse 6000D-04

Impulse 6000D Defibrillator Analyzer Australia

Impulse 6000D-05

Impulse 6000D Defibrillator Analyzer India

Impulse 6000D Defibrillator Analyzer Brazil

Impulse 6000D Defibrillator Analyzer Brazil

Impulse 7000DP

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer 120 V - US

All models include:

  • USB Computer Communication Cable (Cable assembly)
  • User Manual CD (CD-ROM)
  • Getting Started Guide (Manual)
  • Battery Eliminator (country specific)
  • Defib Paddle Contact Plates (FBC-IMP7000-8010)
  • Carrying Case (Soft case)

Impulse 7000DP-01

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer Schuko

Impulse 7000DP-02

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer UK

Impulse 7000DP-03

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer UK

Impulse 7000DP-04

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer Australia

Impulse 7000DP-05

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer India

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer Brazil

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer Brazil

TA-IMP7KDP

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation 120 V US

All models include:

  • USB Computer Communication Cable (Cable assembly)
  • User Manual CD (CD-ROM)
  • Getting Started Guide (Manual)
  • Battery Eliminator (country specific)
  • Defib Paddle Contact Plates (FBC-IMP7000-8010)
  • Carrying Case (Soft case)

TA-IMP7KDP-01

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation Shuko

TA-IMP7KDP-02

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation United Kingdom

TA-IMP7KDP-03

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation Japan

TA-IMP7KDP-04

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation Australia

TA-IMP7KDP-05

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation India

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation Brazil

Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation Brazil

TA-IMP7K/7010 US

Impulse 7000DP US 120 V with Impulse 7010 and test automation United States

All models include

  • USB Computer Communication Cable (CABLE ASSEMBLY)
  • User Manual CD (CD-ROM)
  • Getting Started Guide (Manual)
  • Battery Eliminator (country specific)
  • Defib Paddle Contact Plates (FBC-IMP7000-8010)
  • Carrying Case (Soft Case)
  • Ansur Test-Automation Software (ANSUR IMPULSE 7000)

TA-IMP7K/7010 SHK

Impulse 7000DP with Impulse 7010 and test automation Shuko

TA-IMP7K/7010 UK

Impulse 7000DP with Impulse 7010 and test automation United Kingdom

TA-IMP7K/7010 JPN

Impulse 7000DP with Impulse 7010 and test automation Japan

TA-IMP7K/7010 AUS

Impulse 7000DP with Impulse 7010 and test automation Australia

Impulse 7000DP with Impulse 7010 and test automation Brazil

Impulse 7000DP with Impulse 7010 and test automation Brazil

 

 

Recommended options

Adapters

I6/7 D/P ADPT101

GE Marquette (RESPONDER1500/1700 Series) (set of two) 4mm

I6/7 D/P ADPT102

Internal discharge paddle contacts (set of two)

I6/7 D/P ADPT103

Kimberly Clark/R2 Darox MRL/MDE/NK: 4 mm defibrillator adapters

I6/7 D/P ADPT106

Medtronic ERS/Physio-Control (FAST PATCH) (set of two): 4 mm defibrillator adapters

I6/7 D/P ADPT104

Medtronic ERS/Physio-Control (QUIK COMBO) 4mm

I6/7 D/P ADPT105

Medtronic ERS/Physio-Control (QUIK PACE) (set of two): 4 mm pacer adapters

I6/7 D/P ADPT108

Philips/Agilent HEARTSTART FR2/MRX 4mm

I6/7 D/P ADPT107

Philips/Agilent/HP (CODEMASTER Series-Round) 4mm

I6/7 D/P ADPT110

Zoll Medical NTP/PD1400: 4 mm pacer adapters

l6/7 D/P ADPT109

Zoll PD-2200 Multi-Function PD-Series, M-Series, M-Series CCT, AED PRO® & AED Plus™

 

Miscellaneous Accessories

Impulse 7010

Impulse 7010 Defibrillator Selectable Load Accessory

 

Software

Ansur IMPULSE 7000

Ansur Impulse 6000D/7000DP Plug-In

 

More products FLUKE BIOMEDICAL

ELECTROSURGERY ANALYZER FLUKE BIOMEDICAL QA-ES

• Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor
• High-frequency leakage measurements with accuracy of ± 2 % of reading
• 128 internal user-selectable test loads from 10 O to 5200 O
• Ansur QA-ES software plug-in for automated test protocols
• RS-232 and Centronic-printer interface

 

GAS/ LIQUID PRESSURE TESTER OF MEDICAL EQUIPMENTS FLUKE BIOMEDICAL DPM2PLUS

• Handheld
• Battery operated
• 1 % accuracy
• Five selectable scale ranges
• Voltage output to drive a recorder for assessing electronics of pressure measurement circuit
• Air or liquid measurement


PRESSURIZED ION CHAMBER SURVEY METER FOR GAMMA, X-RAY RADIATION FLUKE BIOMEDICAL 451P

• High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
• Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm
• Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case

 

INCUBATOR ANALYZER FLUKE BIOMEDICAL INCU

• Portability (sitting in place of infant within incubator)
• Single-instrument measurement and documentation for key infant-incubator parameters
• Measurement for most parameters according to IEC and AAMI standards
• Time-saving in testing critical infant incubators
• Windows® software for evaluation and documentation
• Numerical and graphical reports

 

MULTIFUNCTION TESTER OF GAS FLOW, VOLUME, VACUUM, PRESSURE, OXIGEN CONCENTRATION FLUKE BIOMEDICAL VT MOBILE

• Bidirectional flow (high- and low-flow ranges), volume, vacuum, pressure, and oxygen-concentration measurements
• 16 ventilator parameter measurements
• Trending and statistical analysis of all measured values
• Onboard graphical display
• Portable and compact
• RS232 for computer control
• Memory for storing results
• VT for Windows PC software

 

PHOTOTHERAPY RADIOMETER LIGHT RADIATION MEASURING FLUKE BIOMEDICAL DALE40

• Large LCD
• Accurate to ±5% of full scale
• Spectral range of 429-473 nm
• Complete portability


ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA612

• Portable, ergonomic, lightweight, and easy to use
• Large, easy-to-read display with adjustable contrast
• Human-factors-designed user interface
• Tilt stand design for stand-up testing in field environments
• Five applied parts jacks and easy ECG snap connection

 

ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA620

• Compliance with multiple standards
• Three test loads
• Expanded leakage ranges through 10,000 µA
• AC only, DC only and True RMS leakage readings
• 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
• 20 A equipment current

 

DIGITAL ELECTRICAL SAFETY TESTER FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


LIM/ GFI ISOLATION CURRENTS TESTER FLUKE BIOMEDICAL DALE2000

• Unique digital circuitry retains measurement
• Direct reading of Line Voltage, LIM and GFI current
• 9 volt battery operation
• Universal voltages from 85 to 245 VAC, 50/60 Hz
• Small, lightweight, very portable