Three-Channel Precision Laboratory Teslameter Brockhaus GM-460

Code: Brockhaus GM-460


 

Description

  • Three-channel Gaussmeter for determining the magnetic field strength of permanent magnets and systems
  • Measurement of magnetizing pulses
  • User-friendly measuring instrument
  • Mains supply
  • Application in laboratories and in production lines
  • Field and temperature measurement via the probe input
  • Automatic temperature compensation
  • Application as a single-, two- or three-channel Gaussmeter

 

Operating principle

Multi-channel Gaussmeter with a resolution of 5 3/4 digits. Up to a maximum of three probes can be connected simultaneously. Each measuring channel is shown in one line in the display. Measurement of Hall voltage created in the Hall sensor which is proportional to the adjacent magnetic field.

All the functions are displayed and controlled via the front panel of the instrument. Input via keyboard, readings on a 4-line fluorescent display with alphanumerical text. Measuring range, zero, and functions such as max hold, relative or alarm, can be set individually for each channel.

Two analogue outputs provide high accuracy and the possibility to analyse the development of the field. The corrected analogue output shows the exact value displayed, the non-corrected analogue output shows the field strength in real time.

The comprehensive Hall probe programme includes over 500 different measuring probes, as well as conventional transverse and axial probes and probes for bi-and tri-axial measurements. BROCKHAUS also supplies probes for low temperature applications and for measuring minimal magnetic fields.

 

Technical data:

Gaussmeter 460

Measuring mode:

measurement of Hall voltage

Measuring range:

300 mG, 3 G, 30 G, 300 G, 3 kG, 30 kG, 300 kG

Measuring frequency:

DC, 10 Hz - 400 Hz

Measuring accuracy:

± 0,1 % of DC value, ± 2 % of AC value
0,005 % of measuring range

Repeatability:

± 0,0007 %

Measuring rate:

4 measurements/sec / display
18 measurements/sec / interface

Selection of measuring range:

automatic or manual

Resolution:

5 3/4 digits (1 of ± 300.000)

Display:

4-line, vacuum-fluorescence

Probe type:

all laboratory probes

Temperature range:

0°C - 40°C

Analogue outputs:

corrected and non-corrected ± 10 V

Interfaces:

RS-232, IEEE-488

Power supply:

100 - 240 V AC, 50 / 60 Hz

Functions:

Max Hold, Filter, Alarm, Zero Probe, Relative Reading, Auto Range, Memory Hold, AC/DC, Gauss, Tesla, Keylock, Pulse Field Measurement

Accessories:

Zero gauss chamber, power cable, operating manual

Special accessories:

probe cable in lengths 3 / 7,6 / 15,24 / 30,49 m
305 mm zero chamber / interface cable
19" drawer

 

Standard accessories

  • Zero chamber,
  • power cable,
  • operating manual
 

Recommended options

 
probe cable in lengths 3 / 7,6 / 15,24 / 30,49 m
305 mm zero chamber / interface cable
19" drawer
 

Hall probes overview Gaussmeter

 

Axial Probes

Model

L

D

A

Stem Material

Corrected accuracy (%) of reading

Temperature coefficient (maximum) zero

Temperature coefficient (maximum) calibration

MMA-2502-VH

2 " ± 0.063"

0.25" ± 0.006''

0.010"

Aluminum

± 0.25 % to 30 kG

± 0.09 G/°C

- 0.04 %/°C

MNA-1904-VH

4' ± 0.125"

0.187" ± 0.005''

0.005''

Fiberglass
epoxy

MMA-2502-VG

2" ± 0.063''

0.25" ± 0.006''

0.010"

Aluminum

± 0.15 % to 30 kG

± 0.13 G/°C

- 0.005 %/°C

MNA-1904-VG

4' ± 0.125"

0.187" ± 0.005''

0.005"

Fiberglass
epoxy

 

Transverse Probes

Model

L

D

A

Stem Material

Frequency Range

Corrected accuracy (%) of reading

Temperature coefficient (maximum) zero

Temperature coefficient (maximum) calibration

MMT-6J04-VH

4"± 0.125"

0.061" max

0.180"

Aluminum

DC

± 0.25 % to 30 kG

± 0.09 G/°C

- 0.04 %/°C

MNT-4E04-VH

0.045" max

0.150''

Rigid glass epoxy

DC and 10 Hz to 400 Hz

MMT-6J04-VG

0.061" max

0.180"

Aluminum

DC

± 0.15 % to 30 kG

± 0.13 G/°C

- 0.005 %/°C

MNT-4E04-VG

0.045" max

0.180"

Rigid glass epoxy

DC and 10 Hz to 400 Hz

 

Flexible Transverse Probes

Model

W

T

Active Area

Stem Material

Frequency Range

Corrected accuracy (%) of reading

Temperature coefficient (maximum) zero

Temperature coefficient (maximum) calibration

MFT-3E03-VH

0.135" max

0.025" max

0.040" dia (approx)

Flexible
Tubing

DC and 10 Hz to 400 Hz

± 0.25 % to 30 kG

± 0.09 G/°C

- 0.04 %/°C

MFT-3E03-VG

± 0.15 % to 30 kG

± 0.13 G/°C

- 0.005 %/°C

 

 

More products BROCKHAUS

PRECISION LABORATORY TESLAMETER BROCKHAUS GM-475

• Precision laboratory Gaussmeter for determining the magnetic field strength of permanent magnets and systems
• Measurement of magnetizing pulses up to 50 kHz
• User-friendly measuring instrument
• Single-channel Gaussmeter with a resolution of 5 3/4 digits
• measuring accuracy of ± 0,05 % of the measured value
• Measuring range: 35 mG, 350 mG, 3.5 G, 35 G, 350 G, 3.5 kG, 35 kG, 35 kG
• Measuring frequency: DC, 1 Hz - 50 kHz
• Measuring accuracy: ± 0,05 % of DC value, ± 1% of AC value, ± 0,005 % of DC measuring range


FLUXMETER FOR MEASURING ALL MAGNETIC QUALITY PARAMETERS BROCKHAUS F10

• Magnetic flux
• Magnetic flux density
• Magnetic field strength
• Magnetic moment
• Magnetic potential
• Polarization
• Analogue voltage integrator for measuring all quality-related magnetic parameters
• Integrated calibration device

 

HYSTOGRAPH FOR TESTING PARAMETERS OF MAGNETIC MATERIALS BROCKHAUS HG200 AC/DC

• Remanence
• Coercive field strength
• Maximum energy product
• Specific hysteresis loss
• Maximum field strength
• Maximum polarization
• Effective field strength
• Permeability
• Specific apparent output
• Hysteresis display
• Form factor

 

THREE-CHANNEL PRECISION LABORATORY TESLAMETER BROCKHAUS GM-460

• Three-channel Gaussmeter for determining the magnetic field strength of permanent magnets and systems
• Measurement of magnetizing pulses
• resolution of 5 3/4 digits
• Measuring range: 300 mG, 3 G, 30 G, 300 G, 3 kG, 30 kG, 300 kG
• Measuring frequency: DC, 10 Hz - 400 Hz
• Measuring accuracy: ± 0,1 % of DC value, ± 2 % of AC value, 0,005 % of measuring range


GAUSSMETER TESLAMETER FOR MEASURE MAGNETIC FIELD WITH HALL PROBE BROCKHAUS BGM-101

• From DC to 10 kHz AC fields (TRUE RMS)
• Automatic probe detection
• Display in Gauss, Tesla, Oersted or A / m
• Bargraph visualization
• Hand-held device for determining magnetic field strength
• High accuracy of 0,5 % and repeatability
• Data transfer to PC via USB
• Multicolour touch TFT 320 x 240 px

 

PRECISION LABORATORY TESLAMETER BROCKHAUS GM-455 DSP

• Precision laboratory Gaussmeter for determining the magnetic field strength of permanent magnets and systems
• Measurement of magnetizing pulses up to 20 kHz
• User-friendly measuring instrument
• Single-channel Gaussmeter with a resolution of 5 3/4 digits
• measuring accuracy of ± 0,075 % of the measured value
• Measuring range: 35 mG, 350 mG, 3.5 G, 35 G, 350 G, 3.5 kG, 35 kG, 35 kG

 

HALL EFFECT PROBES FOR MEASURING AXIAL AND TRANSVERSE MAGNETIC FIELDS WITH GAUSSMETERS BROCKHAUS

• Probes for Gaussmeter:
• Axial Probes
• Transverse Probes
• Flexible Transverse Probes

 

HYSTOGRAPH FOR HYSTERESIS DIAGRAM, REMANENCE, FIELD STRENGHT, ENERY, POLARIZATION OF MAGNETIC MATERIALS BROCKHAUS HG200

• Remanence
• Coercive field strength
• Maximum energy product
• Maximum field strength
• Maximum polarization
• Hysteresis display
• Measurement of all hard magnetic materials(AlNiCo, ferrite, SmCo, NdFeB, plastic composite)
• Measurement with constant flux alteration dF/dt

 

HELMOLTZ COIL FOR MAGNETIC MOMENT MEASURING BROCKHAUS HC01/HC02

• Helmholtz Coil HC01 150 mm
• Helmholtz Coil HC02 210 mm
• Measuring coil to determine magnetic moment
• Coil constant K= 0,0154cm
• Resitance 35 Ohm

 

GAUSSMETER TESLAMETER LABORATORY HIGH PRECISION BROCKHAUS BGM-201

• Digital precision Gaussmeter for determining the magnetic field strength of permanent magnets and systems
• High accuracy of ± 0.05 %
• DC, AC to 30 kHz (True RMS)
• Multicolour touch TFT 800 x 480 px
• Relative, Auto Zero, Data storage,
• Data transfer to PC via USB