GOODWILL INSTEK PEL-2000A Series

Cod: GOODWILL INSTEK PEL-2000A Series


 

Brosura produs PDF, 8 Mb
         

Descriere

The PEL-2004A and PEL-2002A are multiple channel, programmable DC electronic loads with a modularized structure. The PEL-2000A Series is designed to meet the continuing shift toward high speed operation in today's semiconductor market. As the power supply units, DC-DC converters, and batteries that drive semiconductor circuits to follow this shift, power supply design, quality inspection, and characteristic certification using high-speed performance loads have become necessary. The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.

For higher load capacities, mainframes can be linked together in parallel with standard MIL 20-pin connectors. A maximum of 5 mainframes, including one master and 4 slaves can be chained together to create a total load capacity of 7kW for high current and high power applications. Using 4 dual channel load modules, the PEL-2004A is able to test 8 power supply outputs simultaneously. The Sequence function allows each channel to change its load sink according to a predefined sequence at a rate of up to 100 s per step. Each sequence is able to run concurrently under the control of one clock. This is one of the most powerful features of the PEL-2000A ASeries as it is able to realistically simulate a multi-output power supply load. Under Dynamic mode, the load current or load resistance pulses between two preset levels at a pre-defined speed up to 25 s per step. This is often used as the standard test procedure to verify the response of a power supply to quick load changes. Most remarkably, multiple load channels can be connected in parallel to run Dynamic tests synchronously under a single clock. This Parallel Dynamic functionality gives the flexibility to perform dynamic tests for a high-power power supply without the need of another high-power load.

 

The PEL-2000A Series includes a number of protection modes: Over Current Protection (OCP), Over Voltage Protection (OVP), Over Power Protection (OPP), Reverse Voltage Protection (RVP), and Under Voltage Protection(UVP). The protection modes are useful to protect both the load modules and the DUT(s). A buzzer can be set when a protection setting has been tripped. When a protection mode has been tripped, the load unit will display an alarm and stop sinking current/voltage. When a load unit is operating in CR or CV mode, the unit may need Over Current Protection to prevent excessive current being sunk. Over Current Protection stops the load from sinking more current than its recommended limit and prevents the load from burn-out damage. Over Voltage Protection is used to limit the amount of voltage sink. If the OVP trips, the PEL-2000A Series load will stop sinking voltage. Over Power Protection is used when the input power exceeds the specifications of the load. When OPP is tripped, the power will cease to be sunk. Reverse Voltage Protection prevents reverse voltage damage to the PEL-2000A Series up to the specified rating. When Reverse Voltage Protection has been tripped, an alarm tone will sound until the reverse voltage is removed. Under Voltage Protection will turn off the load when the voltage drops below a set limit. The Go/NoGo function is available to monitor test results all the time. When a test result goes beyond a preset limit range, a "No Go" indication will be shown on the display and a "No Go" signal can be sent out through the D-SUB interface for external device control. This Go/NoGo function is available for CC mode, CV mode, and CR mode. Under "Program" mode, 12 programs, each containing 10 panel setup memories, can be edited to create work routines for repetitive tests. After a program has been executed, the results of all test steps, along with the Go/NoGo judgments, will be shown on the screen. For external control and system configuration, the PEL-2000A series has USB and RS-232 interfaces as standard and GPIB as an option. The LabView driver and Data Logging PC software are both supported for all the available interfaces. Each channel has an analog control/monitoring connector on the rear panel to externally turn a load on/off and to externally monitor load input current and voltage.

 

Features:

  • Sequence function to do high Efficient load simulations
  • Flexible configuration with mainframes and plug-in modules
  • Multiple independent load inputs up to 8 channels in a mainframe
  • Parallel connection of inputs for increased load capacity
  • Parallel connection of inputs for static and dynamic tests
  • OPP/OCP/OVP/OTP protections
  • External channel control/monitoring via an analog control connector
  • Multi-Interface USB Device / Host, RS-232C, and GPIB (Optional)
 

Alte produse INSTEK

GOODWILL INSTEK GOM-802

• 30000 Counts Display
• High Accuracy 0.05%
• Hi/Lo Comparator and Limit Percent Setting
• Measurement of REL, Actual and % Value
• Continuous or Triggered Measurement Mode

 

GOODWILL INSTEK PCS-1000I

• 6 1/2 digit voltage and current measurement resolution
• Simultaneous current and voltage measurement
• Five current measurement levels (AC&DC): 30mA/ 300mA/ 3A/ 30A/ 300A
• AC voltage measurement levels: 200mV/ 2V/ 20V/ 200V/ 600V

 

OSCILOSCOAPE DIGITALE 2/4 CANALE 150/250/350/500MHZ INSTEK GDS-3000

• GDS-3152 150MHz, 2 channel, 2.5GSa/s
• GDS-3154 150MHz, 4 channel, 5GSa/s
• GDS-3252 250MHz, 2 channel, 2.5GSa/s
• GDS-3254 250MHz, 4 channel, 5GSa/s
• GDS-3352 350MHz, 2 channel, 5GSa/s
• GDS-3354 350MHz, 4 channel, 5GSa/s
• GDS-3502 500MHz , 2 channel, 4GSa/s
• GDS-3504 500MHz , 4 Channel , 4GSa/s

 

OSCILOSCOP ANALOGIC 2 X 50 MHZ GW INSTEK GOS-6051

• 50 MHz bandwidth
• 2 analog channels
• 1mV/div ~ 20V/div
• Cursor Measurement, 6 Digit Frequency Counter, 10 sets Memory for Front Panel Setting Save & Recall

 

GOODWILL INSTEK APS-7000 SERIES

• Low Ripple & Noise
• Measurement and test functions include VOLT?CURR?PWR?SVA?IPK?IPKH?FREQ?PF?CF
• Support a small AC current measurement 2mA ~ 35A, Min. resolution 0.01mA(APS- 7050& APS-7100)
• Reverse Current Alarm Function

 

GOODWILL INSTEK MFG-2000 SERIES

• Earth Ground Isolation Design Among I/O Terminals and Instrument Chassis
• Frequency Counter : 150MHz, 8 bits
• AM/FM/PM/ASK/FSK/PSK/SUM/PWM Modulation
• USB Host/USB Device/LAN (MFG-22XX only)
• 4.3 Inch TFT Color Display

 

TRUSA MASURA CURENT DE ATINGERE GW-INSTEK GLC-9000

• Touch Panel with Color LCD Display
• 9 Different Measurement Network to Simulate
• the Resistance of Human Body
• 8 Different Types of Leakage current for Medical
• & General Electrical Equipment
• Various Leakage Current Measuring Mode:DC/AC/AC+DC/AC Peak
• Upper & Lower Limitation for PASS/FAIL Judgment
• Meter Mode with SELV/CONV Function
• 50 Preset Test Conditions Conform to IEC 60990;
• 30 Sets Memories for Customer Defined
• Various Standard Interfaces RS232/GPIB/USB Host & Device/EXT I/O


TESTER RIGIDITATE DIELECTRICA GW-INSTEK GPT-9901A GPT-9902A GPT-9903 GPT-9904

• 500VA AC Test Capacity
• 240x64 Ice Blue Dot matrix LCD
• Sweep Function for DUT characteristic analysis
• Insulation resistance measurement up to 50GO(GPT-9903/9904)
• Manual/Auto Mode
• Interface : RS-232C, USB device, Signal I/O and GPIB (optional)

 

GOODWILL INSTEK GFC-8270H & GFC-8131H

• Frequency and Period Measurement
• High Resolution at Both High and Low Frequency
• 0.01Hz~2.7GHz Frequency Range(GFC-8270H)
• 0.01Hz~1.3GHz Frequency Range(GFC-8131H)
• 10mV rms High Sensitivity

 

GOODWILL INSTEK GUT-6600A

• Easy-Operating Tester, Particularly be Designed for the Digital IC
• Supported Device:74/54/40/45 Serial, Drive 2xxx
• Small, Portable, Light and Power-Saving, Usable With Battery
• Average Search Time: 0.6 Second
• Display: 16 Characters in 1 Line LCD
• Test Pins: 14~24 Pins