Brand: HART SCIENTIFIC

Baie portabila calibrare temperatura -25°C..150°C Hart Scientific 9142

Cod: Hart Scientific 9142


 

Brosura produs PDF, 3 Mb
 

Descriere

  • -25 °C to 150 °C (-13 °F to 302 °F) Temperature Range at 23 °C
    Lightweight, portable, and fast
  • Cool to -25 °C in 15 minutes
  • Built-in two-channel readout for PRT, RTD, thermocouple,
  • 4-20 mA current
  • True reference thermometry with accuracy to ± 0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading
 

Optiuni recomandate

9142-X

Field Metrology Well, -25 °C to 150 °C, w/9142-INSX

9142-X-P

Field Metrology Well, -25 °C to 150 °C, w/9142-INSX, w/Process Electronics

X in the above model numbers to be replaced with A, B, C, D, E, or F as appropriate for the desired insert. See the inserts illustration and listing below.

9142-INSA

Insert "A" 9142, Imperial Misc Holes

9142-INSB

Insert "B" 9142, Imperial Comparison Holes

9142-INSC

Insert "C" 9142, 0.25-inch Holes

9142-INSD

Insert "D" 9142, Metric Comparison Holes

9142-INSE

Insert "E" 9142, Metric Misc Holes w/0.25-inch Hole

9142-INSF

Insert "F" 9142, Metric Comparison Misc Holes w/0.25-inch Hole

9142-INSZ

Insert "Z" 9142, Blank

 

Alte produse HART SCIENTIFIC

BAIE DE ULEI TERMOSTATATA CALIBRARE TEMPERATURA -30°C..125°C HART SCIENTIFIC 7103

• -30 °C to 125 °C range
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.03 °C

 

BLOC DUBLU CALIBRARE TEMPERATURI PENTRU INDUSTRIE -15°C..350°C HART SCIENTIFIC 9009

• Temperatures from -15 °C to 350 °C in one unit
• 50 °C to 350 °C Hot block, ± 0.6 °C Accuracy
• -15 °C to 110 °C Cold Block, ± 0.2 °C Accuracy
• ± 0.05 °C Stability

 

BAIE PORTABILA CALIBRARE TEMPERATURA -25°C..150°C HART SCIENTIFIC 9142

• -25 °C to 150 °C (-13 °F to 302 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Cool to -25 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.01 °C

 

CALIBRATOR TEMPERATURA INFRAROSU -15°C..120°C HART SCIENTIFIC 4180

• Fast, portable and easy to use
• Correct target size for most thermometers
• Calibration solutions from -15 °C to 120 °C
• Radiometrically calibrated for traceable and consistent results

 

BLOC USCAT PORTABIL CALIBRARE TEMPERATURA 50°C..650°C HART SCIENTIFIC 9141

• 50 °C to 650 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.05 °C stability

 

TERMOMETRU REFERINTA DE PRECIZIE 4 CANALE HART SCIENTIFIC 1529 CHUB-E4

• Four channels for PRTs, thermistors, and thermocouples
• Displays eight user-selected data fields from any channel
• Logs up to 8,000 readings with date and time stamps
• Battery provides eight hours of continuous operation

 

BAIE CALIBARE TERMOMETRE 35°C..425°C HART SCIENTIFIC 9172

• 35 °C to 425 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

BAIE DE ULEI TERMOSTATATA CALIBRARE TEMPERATURA 35°C..200°C HART SCIENTIFIC 6102

• 35 °C to 200 °C range
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.02 °C

 

BAIE PORTABILA CALIBRARE TEMPERATURA 33°C..350°C HART SCIENTIFIC 9143

• 33 °C to 350 °C (91 °F to 662 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.02 °C

 

BLOC USCAT PORTABIL CALIBRARE TEMPERATURI -40°C..140°C HART SCIENTIFIC 9007

• Designed for on-ship and on-the-go lab applications
• Covers -40 °C to 140 °C
• Includes three-inch and six-inch calibration zones