Brand: HART SCIENTIFIC

Calibrator temperatura, termometre, termistoare Hart Scientific 1594A / 1595A

Cod: Fluke Hart Scientific 1594A 1595A


 

Brosura produs PDF, 1.13 Mb

Descriere

  • Calibrate SPRTs, PRTs, RTDs and thermistors (0 O to 500 kO)
  • Accuracy as good as 0.06 ppm (0.000015 °C)
  • "Ratio Self-Calibration" verifies and calibrates resistance ratio accuracy
  • Automatic zero-power measurements calculate thermometer probe self-heating
  • Temperature-controlled internal reference resistors
  • Calibrated sensing current lowers overall instrument uncertainty
  • Four input channels on the front panel accept sensors under test or external references
  • Two dedicated external reference input channels on the rear panel
  • Standby current reduces transient effects when scanning between channels
  • Channel Select keys turn measurement mode on or off at the touch of a button
  • Sample rates as fast as one second
  • USB data transfer and computer control
  • Remote view and device control via Ethernet
  • Compatible with MET/TEMP II automated calibration software and LogWare II multi-channel, real-time data acquisition software
 

Accesorii standard

  • NVLAP-accredited certificate of calibration
  • user’s guide on CD-ROM
  • technical guide (English only) on CD-ROM
  • RS-232 to USB converter cable
  • regional power cord
 

Optiuni recomandate

  • 1594A  Super-Thermometer, 0.8 ppm           
  • 1595A  Super-Thermometer, 0.2 ppm    
 

Accessories

1594-CASE

Case, 1594/95 Carrying                           

1594-HNDL

Handle, Frnt/Back Carrying

1594-SIDEHNDL

Kit, 1594/95 Side Carrying Handle                

1594-HNDLCVR

Handle, Cover

Y159X

Kit, 1594/95 Rack Mount

1594-MUXCBL

Cable, 2590 Multiplexer

1594-MUXINPUT

Cable, 2590 Scanner Channel Input

2383-1

Cable, Serial to USB Converter

 

Probe Adapters

2571

Adapter, DWF to Spade Lugs, 1-Channel

2572-1

Adapter, 5-pin (F) DIN to Spade Lugs

2373

Adapter, INFO-CON to Spade Lug

2373-DIN

Adapter, Rnd INFO-CON to
Spade Lug (914x) 

2373-LSP

Adapter, Female Lemo to Spade Lug

 

Standard Resistors*

5430-25

Resistor, AC/DC Standard w/ Cal,
25 O 1-year stability, 2 ppm

5430-100

Resistor, AC/DC Standard w/ Cal, 100 O 1-year stability, 2 ppm

742A-25

Resistor, DC Standard, 25 O
1-year stability, 8 ppm

742A-100

Resistor, DC Standard, 100 O
1-year stability, 6 ppm

* See catalog or website for more information

 

Software

9938

Software, Met/Temp II

9935-S

Software, LogWare II, 2+-Chan, Single User

9935-M

Software, LogWare II, 2+-Chan, Multi User

 

Calibration Options

CAL-1594A

Recal With As-Found Data                         

CAL-1595A

Recal With As-Found Data                         

1994

Verification, Extended Range,
100-500 k Ohms,1594A

1995

Verification,  Extended Range,
100-500 k Ohms,1595A

1960

Cal, Standard AC/DC Resistor    

 

 

Alte produse FLUKE

TERMOMETRU REFERINTA DE PRECIZIE HART SCIENTIFIC 1523

• Single channel standard model
• High accuracy
• PRTs: up to ± 0.011 °C
• Thermocouples: up to ± 0.24 °C
• Precision thermistors: ± 0.002 °C

 

CUPTOR CALIBRARE TERMOCUPLE 300°C..1100°C HART SCIENTIFIC 9112B

• 300 °C to 1100 °C temperature range
• Combined stability and uniformity better than ±0.4°C
• RS-232 serial interface standard
• High capacity for simultaneous comparison calibrations

 

CALIBRATOR TEMPERATURA INFRAROSU -15°C..120°C HART SCIENTIFIC 4180

• Fast, portable and easy to use
• Correct target size for most thermometers
• Calibration solutions from -15 °C to 120 °C
• Radiometrically calibrated for traceable and consistent results

 

TERMOMETRU REFERINTA DE PRECIZIE 2 CANALE HART SCIENTIFIC 1524

• Two channels
• High accuracy
• PRTs: up to ± 0.011 °C
• Thermocouples: up to ± 0.24 °C
• Precision thermistors: ± 0.002 °C
• memory for logging 15,000 measurements

 

TERMO-HIGROMETRU LOGGER HART SCIENTIFIC DEWK 1620A

• Superior accuracy
• NEW! Network enabled
• Powerful logging and analysis tools
• Two interchangeable calibrated sensors
• Huge memory

 

BAIE CALIBARE TERMOMETRE 50°C..700°C HART SCIENTIFIC 9173

• 50 °C to 700 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

BLOC USCAT PORTABIL CALIBRARE TEMPERATURA 35°C..350°C HART SCIENTIFIC 9140

• 35 °C to 350 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.03 °C stability

 

BLOC USCAT PORTABIL CALIBRARE TEMPERATURI -40°C..140°C HART SCIENTIFIC 9007

• Designed for on-ship and on-the-go lab applications
• Covers -40 °C to 140 °C
• Includes three-inch and six-inch calibration zones


CALIBRATOR TERMOMETRE INFRAROSU -30°C..150°C HART SCIENTIFIC 9133

• Certify IR pyrometers from -30 °C to 150 °C
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design

 

BAIE CALIBARE TERMOMETRE -30°C..155°C HART SCIENTIFIC 9171

• -30 °C to 155 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world