Electrical Specifications

Data Logging

127 data points using front panel controls

Frequency Response, Electric Fields

2 kHz - 300 kHz, ± 2 dB

Frequency Response, Magnetic Fields

8 kHz - 300 kHz, ± 2 dB

Magnetic Field Units

User Selectable (amperes/meter, gauss, tesla)

Power Supply

2 - 9 volt batteries

Sensitivity, Electric Field

1 - 2000 Volts/meter in three ranges

Sensitivity, Magnetic Field

1 - 2000 Milliamperes/meter in three ranges

 

Accesorii standard

  • Tripod Mounting Socket
  • User Manual
  • Dielectric Handle
  • Custom Carrying Case
 

Optiuni recomandate

  • 491008 Dielectric Floor stand
  • 4413 Serial Interface
  • 491009 Dielectric Tripod
  • HI-3616 Remote Control Readout
  • Dielectric Spacer (30 cm) for VDT measurements
  • Plastic Fiber Optic Cable
 

Alte produse ETS-LINDGREN

FILTRE DE PUTERE PROTECTIE RADIATII RFI/ EMI CURENT REDUS SCURGERE PAMANT APLICATII MOBILE 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HORN PIRAMIDAL MULTI-OCTAVA LINIAR POLARIZATA 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear

 

TESTER CAMP MAGNETIC 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 20 HZ..5 MHZ ETS-LINDGREN 6511

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

INCINTA ECRANATA TESTARE DISPOZITIVE WIRELESS ETS-LINDGREN 5247

• Roll-About Casters
• Portable RF Shielded Enclosure for OTA measurements
• >80 dB Typical RF Isolation
• RF Absorber Lined
• Dual Polarized Horn Antenna
• 700 MHz - 10 GHz Frequency Range
• Linear & Circular Polarization

 

ANTENA LOG-PERIODICA DIRECTIVA BANDA LARGA 200 MHZ..5 GHZ ETS-LINDGREN 3147

• Frequency Minimum 200 MHz
• Frequency Maximum 5 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 80 W
• Pattern Type directional
• Peak Power 100.0 W
• VSWR 1.2:1

 

ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

SONDE MASURA CURENTI 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection