Descriere

  • 0.06 mG - 400 G (with 100X probe)
  • 2 - 400 kHz
  • True RMS Detection
  • Three concentric orthogonal field sensors

 

Electrical Specifications

Battery

12 Volt Rechargeable

Frequency Response

2 kHz - 400 kHz

Sensitivity (in five ranges)

100 x Sensor: 600 nT-40mT (60 mG-400 G)
Std. Sensor: 6 nT-400 µT (0.06 mG-4 G)

Sensor

3 Concentric, Orthogonal, Shielded Sensor Coils (0.01 m2 nominal sensing area)

 

Accesorii standard

  • Battery Charger
  • Custom Fitted Carrying Case
  • User Manual
 

Optiuni recomandate

  • Probe - Tripod adaptor
  • 491009 Dielectric Tripod
  • 100X Probe
 

Alte produse ETS-LINDGREN

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BOBINA HELMHOLTZ MONOAXIALA GENERARE CAMP MAGNETIC UNIFORM FRECVENTE JOASE ETS-LINDGREN 6400

• Excellent for Magnetic Immunity Testing
• A Source for Calibration
• Custom Models Available

 

INCINTA ECRANATA TEST TRANSMISIE/ RECEPTIE PUNCT DE ACCES WLAN ETS-LINDGREN 5225

• Works with 802.11 Traffic Generator and Performance Analyzers
• Tests:
• -- Over-The-Air Performance of TX, RX
• -- Wireless LAN Access Point Throughput Performance
• Flat Coupling Response over 2.2GHz - 2.6GHz, 5.2GHz - 6.0GHz

 

FILTRU PUTERE APLICATII TEMPEST/ EMP DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

FILTRE PROTECTIE TEMPEST/RFI/ EMI PETRU LINII TRANSMISII DATE ANALOGICE/ DIGITALE ETS-LINDGREN N2460

• Suitable for EMI and Tempest Protection
• Digital and analogue transmissions
• Tubular, flat-pack or modular design

 

ANTENA DIPOL MAGNETIC BUCLA REZONANTA MASURATORI RIPLU TELECOMUNICATII MOBILE SI INTERNET CTIA 440..2665 MHZ ETS-LINDGREN 3127

• Range of Frequencies to Cover Wireless Device Bands: 440...2665 MHz
• Designed for CTIA Ripple Test
• Meet CTIA +/- 0.1 dB Symmetry Requirement

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

CELULA REVERBERANTA TESTE EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE RADIATA 1..40 GHZ ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

FILTRE PROTECTIE EVENIMENTE TRANZITORII RETEA TRIFAZATA APLICATII RFI/EMP PUTERE & CURENT INALT 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

ANTENA BUCLA MAGNETICA ECRANATA FRECVENTA JOASA 30 HZ..100 KHZ ETS-LINDGREN 7605/ 7606

• Frequency Minimum 30 Hz
• Frequency Maximum 100 kHz
• Connectors Banana Jack (2) - [7605], BNC - [7606]
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear